Internal Ref. | Issue |
3227873 | Description: Fixed an issue that caused RDE (Redfish) PATCH operation to LLDPTransmit properties "ManagementAddressIPv4", "ManagementAddressIPv6" and "ManagementAddressMAC" to be applied only in the first attempt but failed in the next. |
Keywords: RDE (Redfish) PATCH operation | |
Discovered in Version: 28.34.1002 | |
Fixed in Release: 28.35.1012 | |
3172302 | Description: Fixed an issue that caused the commands sent by the MLNX_OFED driver to the NIC to fail when loading the VirtIO driver. |
Keywords: vDPA, virtio-net full emulation | |
Discovered in Version: 28.34.1002 | |
Fixed in Release: 28.35.1012 | |
3184625 | Description: Fixed an issue that caused PLDM AEN event receiver media to be changed unexpectedly and destination BDF to be overridden with garbage when some PLDM packet were received from the SMBus layer. |
Keywords: PLDM AEN event receiver media | |
Discovered in Version: 28.34.1002 | |
Fixed in Release: 28.35.1012 | |
3194359 | Description: Fixed PCIe SKP OS generation interval for Gen1 and Gen2. |
Keywords: PCIe SKP | |
Discovered in Version: 28.34.1002 | |
Fixed in Release: 28.35.1012 | |
2824427 | Description: Running with a debug firmware reduces security as if token was applied. |
Keywords: Debug Firmware | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.35.1012 | |
3110205 | Description: Fixed inconsistent TCP performance when sending multiple streams. |
Keywords: Performance | |
Discovered in Version: 28.34.1002 | |
Fixed in Release: 28.35.1012 |
Internal Ref. | Issue |
3110205 | Description: Fixed inconsistent TCP performance when sending multiple streams. |
Keywords: Performance | |
Discovered in Version: 28.34.1002 | |
Fixed in Release: 28.34.4000 | |
3138401 | Description: Fixed an issue that caused host's PCI device to disappear after running 12V cycles in a loop while there was traffic between the hosts in a Multi-Host platform. |
Keywords: PCI device, Multi-Host platform, 12V cycles | |
Discovered in Version: 28.34.1002 | |
Fixed in Release: 28.34.4000 | |
3148833 | Description: Fixed an issue that resulted in lack of communication with the BMC from the host (IPv4/IPv6) when using BMC version v2022.22.1. |
Keywords: BMC | |
Discovered in Version: 28.34.1002 | |
Fixed in Release: 28.34.4000 | |
3143956 | Description: When connecting a ConnectX-7 adapter card to ConnectX-7 adapter card, once in few fwresets the link may raise in 1G speed instead of the highest speed enabled. |
Keywords: Speed rate | |
Discovered in Version: 28.34.1002 | |
Fixed in Release: 28.34.4000 |
Internal Ref. | Issue |
2931516 | Description: Added support for SPDM Get_measurements command. Note: Executing the command with a signature request without measurements, can cause an invalid L1 hash calculation. |
Keywords: SPDM | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3091233 | Description: Added support for SPDM Challenge command. |
Keywords: SPDM | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
2907008 | Description: Fixed PCIe link down failures during PCIe speed change tests. |
Keywords: PCIe, link down | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3134894 | Description: Fixed an issue where set_flow_table_entry failed when aso_flow_meter action was used. |
Keywords: ASO Flow Meter, FW Steering | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.34.1002 | |
3039007 | Description: Enabled Multi-Host RX Rate-limiter configuration via the QEEC mlxreg and the max_shaper_rate field. |
Keywords: RX Rate-Limiter, Multi-host | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3059379 | Description: Added "Command Unsupported" response code in cases when running the MCTP control command "Get Vendor Defined Messages Supported", and there were no supported VDMs. |
Keywords: MCTP control command | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3133476 | Description: Added the following new checks to commands' interface:
|
Keywords: Command checks | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3047521 | Description: Implemented a firmware flow to power up/down the PLL from downstream links upon PERST assertion/de-assertion. |
Keywords: PLL, PERST | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3132594 | Description: MAC allocation in adapter cards that support Port-Per-Host feature ("host isolation") is reordered to fit the required range. |
Keywords: MAC allocation, PortPerHost | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3085879 | Description: On rare occasions, when connecting a ConnectX-7 adapter card to an NVIDIA Spectrum-3 switch system using the optical cable OPN MFA1A00-C003, the link up time is ~7sec. |
Keywords: Optical cables, link up time | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
2994292 | Description: Fixed a race condition occured between the duplicate read and QP commands (2RST, 2ERR and Destroy) in the signature that caused the command to hang. |
Keywords: Race condition | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.34.1002 | |
3023847 | Description: Enabled sending and receiving traffic with a different LID than the host LID in MetroX applications. |
Keywords: MetroX, LID based | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3023847 | Description: Enabled sending and receiving traffic with a different LID than the host LID in MetroX applications. |
Keywords: MetroX, LID based | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
2920813 | Description: The an_disable flow is not supported in ConnectX-7 adapter cards for 25GbE and 50G_2x link speeds when using one of the following cables:
The flow is supported only when configuring FEC using the PPLM register. |
Keywords: AN, cables, 25GbE, FEC | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3039348 | Description: Host Chaining is currently not supported in ConnectX-7 adapter cards. |
Keywords: Host Chaining | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3023751 | Description: Link flapping may occur when using ConnectX-7 adapter cards with HDR optic cables. |
Keywords: Link flapping, HDR optic cables | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3046168 | Description: Congestion Control is not enabled when one link type of different ports is different. |
Keywords: Congestion Control, Link Type, PCC | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3009525 | Description: A Bit Error Rate (BER) of 1e-9 might occur when using optical cables. |
Keywords: BER | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3036791 | Description: Configuring 400G_8x in force mode is currently not supported. |
Keywords: 400G_8x in force mode | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3004352 | Description: LRO is currently not supported. |
Keywords: LRO | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 |
Internal Ref. | Issue |
2969829 | Description: On rare occasions, the HDR speed link up time when using the optical module MFA7U10-H010 might take up to 70sec. |
Keywords: HDR, link up time, optical cable | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3024199 | Description: When connecting a ConnectX-7 adapter card to an NVIDIA Quantum switch using the copper cable (MCP1600-E01AE30), the link is Down when in EDR speed. |
Keywords: EDR, copper cable, NVIDIA Quantum | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
2947588 | Description: Trying to query/burn the firmware using the flint utility when the image is pending (after firmware burn and before firmware reset), results in the action's failure. |
Keywords: flint, query/burn firmware | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3047723 | Description: When changing the protocols from ETH to IB on two ConnectX-7 adapter cards connected to each other, the ports on both sides must be toggled to get the link up. |
Keywords: Linkup, port toggling, protocol change | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3033874 | Description: Connecting a ConnectX-7 adapter card to either a ConnectX-5 adapter card or to an NVIDIA Spectrum switch system is supported only when using a 100GbE optic cables and when configuring ConnectX-5 or the NVIDIA Spectrum switch system to Force Mode. |
Keywords: Linkup connectivity | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 |