Bug Fixes in this Firmware Version
Internal Ref. |
Issue |
4149727 |
Description: Fixed a rare certificate signature verification error. |
Keywords: Certificate signature verification |
|
Discovered in Version: 28.35.4030 |
|
Fixed in Release: 28.35.4506 |
|
4149778 |
Description: PLDM includes port temperature sensor PDR only if an active cable is connected. |
Keywords: Temperature sensor PDR |
|
Discovered in Version: 28.35.4030 |
|
Fixed in Release: 28.35.4506 |
|
4149836 |
Description: PLDM connector PDR is not reported if a cable is not connected to prevent incomplete data display. |
Keywords: PLDM connector PDR |
|
Discovered in Version: 28.35.4030 |
|
Fixed in Release: 28.35.4506 |
|
4149693 |
Description: Changed PCIe Geen4/5 new static configuration for VGA gain and CTLE. |
Keywords: PCIe, VGA, CTLE |
|
Discovered in Version: 28.35.4030 |
|
Fixed in Release: 28.35.4506 |
|
4149486 |
Description: Fixed lossless packet drops at 400GB 4 lanes when using an optic fiber cable. |
Keywords: 400GB, 4 lanes, optic fiber cable |
|
Discovered in Version: 28.35.4030 |
|
Fixed in Release: 28.35.4506 |
|
4149511 |
Description: Fixed an issue that resulted in setup crash when create_sq used invalid mbox. Now the invalid mbox is replaced with a valid DB. |
Keywords: mbox |
|
Discovered in Version: 28.35.4030 |
|
Fixed in Release: 28.35.4506 |
|
4149392 |
Description: Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4-bytes aligned. |
Keywords: Address validation, 0x0032 |
|
Discovered in Version: 28.35.4030 |
|
Fixed in Release: 28.35.4506 |