NVIDIA ConnectX-7 Adapter Cards Firmware Release Notes v28.39.3560 LTS
NVIDIA ConnectX-7 Adapter Cards Firmware Release Notes v28.39.3560 LTS

Known Issues

VF Network Function Limitations in SR-IOV Legacy Mode

Dual Port Device

Single Port Device

127 VF per PF (254 functions)

127

VF Network Function Limitations in Switchdev Mode

Dual Port Device

Single Port Device

127 VF per PF (254 functions)

127

VF+SF Network Function Limitations in Switchdev Mode

Dual Port Device

Single Port Device

  • 127 VF per PF (254 functions)

  • 512 PF+VF+SF per PF (1024 functions)

  • 127 VF (127 functions)

  • 512 PF+VF+SF per PF (512 functions)

Internal Ref.

Issue

3795140

Description: Firmware cannot reach the line rate with a single QP while running traffic.

Workaround: N/A

Keywords: Line rate, MCX750500B-0D0K / MCX750500B-0D00

Discovered in Version: 28.39.3004

3649572

Description: Downgrading from firmware version 28.39.2048 to a lower one requires performing a Power Cycle after firmware burning and not fwreset.

Workaround: N/A

Keywords: Firmware downgrade, power cycle

Discovered in Version: 28.39.1002

3614362

Description: When connected to a Spectrum-1 switch system using NRZ 25G optic module supporting DME in NO FEC, an EFF BER of -13 may be seen once in 200 toggles.

Workaround: To raise the link, re-toggle the port.

Keywords: Spectrum-1, NRZ, BER, port toggling

Discovered in Version: 28.39.1002

3629216

Description: mlxfwreset level 3 command is not supported for MCX750500B-0D00 / MCX750500B-0D0K / MCX755206AS-NEAT-N P/N.

Workaround:

  1. Enable mlxfwreset level 4.

    mlxfwreset -d <dev> r -l 4 -y

  2. Reboot the server.

Keywords: mlxfwreset level 3

Discovered in Version: 28.39.1002

-

Description: The I2C clock fall time is lower than the 12ns minimum defined in the I2C-bus specification.

For further information, refer to the I²C-bus Specification, Version 7.0, October 2021, https://www.i2c-bus.org/.

Workaround: N/A

Keywords: I2C clock

Discovered in Version: 28.39.1002

3179534

Description: 25G/lane speeds are not supported on 200GbE optic cables.

Workaround: N/A

Keywords: Cables, 200GbE

Discovered in Version: 28.39.1002

3606136

Description: In rare cases, linkup time of NDR and NDR200 with MMA4Z00-NS400 may take longer than 60 seconds.

Workaround: N/A

Keywords: Cables, NDR, NDR200, linkup time

Discovered in Version: 28.39.1002

3435259

Description: The host enables the device to populate only 1 bus. When opening extra 2 Physical ports, moving from dual-port to quad-port, the user can open 2 less Virtual Functions.

Workaround: N/A

Keywords: VF, dual-port, quad-port

Discovered in Version: 28.39.1002

3525865

Description: Unexpected system behavior might be observed if the driver is loaded while reset is in progress.

Workaround: N/A

Keywords: Sync 1 reset, firmware reset

Discovered in Version: 28.39.1002

3363753

Description: The link is down when connected to the MMS1V00-WM (DR4) optical module.

Workaround: N/A

Keywords: 400G, link down

Discovered in Version: 28.38.1002

3439438

Description: When connecting to a High Speed Traffic Generator in 400G speed, the linkup time may takes up to 3 minutes.

Workaround: N/A

Keywords: 400G, linkup time

Discovered in Version: 28.38.1002

3457472

Description: Disabling the Relaxed Ordered (RO) capability (relaxed_ordering_read_pci_enabled=0) using the vhca_resource_manager is currently not functional.

Workaround: N/A

Keywords: Relaxed Ordered

Discovered in Version: 28.37.1014

3275394

Description: When performing PCIe link secondary-bus-reset, disable/enable or mlxfwreset on AMD based Genoa systems, the device takes longer then expected to link up, due to a PCIe receiver termination misconfiguration.

Workaround: N/A

Keywords: PCIe

Discovered in Version: 28.37.1014

-

Description: When upgrading from firmware v28.35.2000 to a newer one, the default port speeds of adapter cards MCX755106AS-HEAT/ MCX755106AC-HEAT will change from InfiniBand to Ethernet.

Workaround: To change it back to InfiniBand, please follow the instructions in the ConnectX-7 hardware User Manual.

Keywords: Firmware upgrade, port type, MCX755106AS-HEAT/ MCX755106AC-HEAT

Discovered in Version: 28.37.1014

3376224

Description: FEC override is not supported when working with NRZ speeds on PAM4 Optical modules.

Workaround: N/A

Keywords: FEC override, NRZ, PAM4

Discovered in Version: 28.37.1014

3262845

Description: In the ConnectX-7 adapter card with P/N MCX750500B-0D0K, t he "Fatal Error Reporting Enable" bit controls both the fatal and the non-fatal ERR MSG forwarding. The "Non-Fatal Error Reporting Enable" bit does not affect the ERR MSG forwarding.

Workaround: N/A

Keywords: Fatal Error Reporting Enable" bit, PCIe, MCX750500B-0D0K

Discovered in Version: 28.36.1010

3312483

Description: WoL packets may not working properly if sent to Unicast destination MAC.

Workaround: N/A

Keywords: WoL packets, Unicast destination MAC

Discovered in Version: 28.36.1010

3339919

Description:

  • When raising a link using 200G optical cables while connecting a ConnectX-7 to a ConnectX-7, raising a link with width less than the maximum provided by the cable with speed 25G lane is not supported.

  • When raising a link using 400G optical cables while connecting a ConnectX-7 to a ConnectX-7, raising a link with width less than the maximum provided by the cable with speed 50G or 25G lane is not supported.

Workaround: To raise in Force flow, configure the speed, FEC and precoding.

Keywords: Link up speed

Discovered in Version: 28.36.1010

3339818

Description: When performing a stress toggling on a ConnectX-7 adapter card that is connected to the MMA1Z00-NS400 cable and the speed is set to 100G_1x with interleaved FEC, a long linkup time of up to 5 min may occur.

Workaround: N/A

Keywords: Toggling, MMA1Z00-NS400

Discovered in Version: 28.36.1010

3329109

Description: MFS1S50-H003E cable supports only HDR rate when used as a split cable.

Workaround: N/A

Keywords: HDR, split cable, MFS1S50-H003E

Discovered in Version: 28.36.1010

2844036

Description: When using the "Dual Write" feature with QP buffer bigger than the maximum outstanding WQEs (128), the data being sent on the standby QP can be corrupted.

Workaround: Limit the QP buffer size when using "Dual Write" up to 128 WQEs.

Keywords: Dual-write, QP

Discovered in Version: 28.36.1010

3178339

Description: PCIe PML1 is disabled.

Workaround: N/A

Keywords: PCIe PML1

Discovered in Version: 28.35.1012

3110297

Description: When ConnectX-7 adapter card is configured to use the Auto-Negotiation mode, 400G_8x linkup cannot be raised.

Workaround: Configure the adapter card to use Force mode.

Keywords: 400G_8x, linkup

Discovered in Version: 28.34.4000

3033910

Description: BAR misses caused by a memory write/read actions are not reported in the AER and the device status.

Workaround: N/A

Keywords: BAR miss, AER

Discovered in Version: 28.34.4000

3140645

Description: 3rd party servers may hang after warm reboot due to the PCIe switch.

Workaround: N/A

Keywords: PCIe, 3rd party servers

Discovered in Version: 28.34.4000

-

Description: Changing dynamic PCIe link width is not supported.

Workaround: N/A

Keywords: PCIe

Discovered in Version: 28.34.1002

3174038

Description: SPDM requests received while CPLD burn flow is in progress may be answered with incorrect responses.

Workaround: Avoid activation of the two flows in tandem.

Keywords: SPDM

Discovered in Version: 28.34.1002

3141072

Description: The "max_shaper_rate" configuration query via QEEC mlxreg returns a value translated to hardware granularity.

Workaround: N/A

Keywords: RX Rate-Limiter, Multi-host

Discovered in Version: 28.34.1002

2870970

Description: GTP encapsulation (flex parser profile 3) is limited to the NIC domain.

Encapsulating in the FDB domain will render a 0-size length in GTP header.

Workaround: N/A

Keywords: GTP encapsulation

Discovered in Version: 28.34.1002

3081264

Description: 10G/40G speeds are not supported on MFS1S00-XXXX modules (200G optics) in ConnectX-7 adapter cards.

Workaround: N/A

Keywords: Optical cables

Discovered in Version: 28.33.4030

3070590

Description: PLL modules are not supported in ConnectX-7 ethernet adapter cards.

Workaround: N/A

Keywords: PLL

Discovered in Version: 28.33.4030

3070409

Description: When connecting a ConnectX-7 adapter card to a ConnectX-6 Dx or an NVIDIA Spectrum-3 switch, NRZ speeds are not raised when using 200GbE optical cable.

Workaround: Configure PHY_FEC_OVERRIDE on the ConnectX-7 side for the requested speed.

Keywords: Optical cables, NRZ, ConnectX-6 Dx, NVIDIA Spectrum-3, 200GbE optical cable

Discovered in Version: 28.33.4030

2993531

Description: PML1 is disabled by default. Enabling it might result in server hanging.

Workaround: N/A

Keywords: PML1

Discovered in Version: 28.33.2028

-

Description: Upgrading to firmware 28.33.2028 from any previous Engineering Sample (earlier than version 28.98.2406) must be done before installing WinOF-2 v2.90 driver and requires going through the following steps:

  1. Upgrade to 28.98.2406 version while the driver is disabled.

  2. Upgrade to firmware version 28.33.2028 (the driver can be enable at this stage).

Workaround: N/A

Keywords: Firmware upgrade

Discovered in Version: 28.33.2028

-

Description: Downgrading from firmware 28.33.2028 to any previous Engineering Sample firmware is not supported.

Workaround: N/A

Keywords: Firmware downgrade

Discovered in Version: 28.33.2028

© Copyright 2024, NVIDIA. Last updated on Jul 2, 2024.