Known Issues
VF Network Function Limitations in SR-IOV Legacy Mode & in Switchdev Mode
Dual Port Device | Single Port Device |
127 VF per PF (254 functions) | 127 |
VF+SF Network Function Limitations in Switchdev Mode
Dual Port Device | Single Port Device |
|
|
ConnectX-8 has the same feature set and limitations as ConnectX-7 adapter card. For the list of ConnectX-7 Known Issues, please go to https://docs.nvidia.com/networking/software/adapter-firmware/index.html#connectx-7.
The below are limitations related to ConnectX-8 only.
Internal Ref. | Issue |
4412310 | Description: Split operation (port splitting) on the second port is not supported on the ConnectX-8 SuperNIC model 900-9X81Q-00CN-ST0. |
Workaround: N/A | |
Keywords: Port splitting | |
Detected in version: 40.45.1020 | |
4394475 | Description: The existing congestion control configuration applies globally, rather than on a per-priority basis. |
Workaround: Ensure that the configuration values for all priorities are aligned in either | |
Keywords: Congestion control, ROCE_CC_PRIO | |
Detected in version: 40.45.1020 | |
4366117 | Description: Configuring a small MTU leads to fragmentation of packets critical for the PXE boot process. As a result, the PXE boot filters mistakenly discard these packets, causing the PXE boot to fail. |
Workaround: If this capability is not disabled by default on your adapter cards (
| |
Keywords: PXE boot filters | |
Detected in version: 40.45.1020 | |
4240828 | Description: Simultaneous access to the same PDDR module info page is not supported. |
Workaround: N/A | |
Keywords: PDDR module | |
Detected in version: 40.45.1020 | |
4318063 | Description: When running the PTP4L application, the path delay displays inconsistent values after each fwreset and rerun, resulting in a non-constant PPS offset that fails to meet Class B/C requirements. |
Workaround: Manually perform a port link reset after fwreset. | |
Keywords: PTP | |
Detected in version: 40.45.1020 | |
4163634 | Description: When connecting a Quantum-3 switch system (with a port split into 8 ports) to a ConnectX-8 single port SuperNIC, the link will not be established. |
Workaround: Configure the Quantum-3 switch system port to be split into 2 or 4 ports, or set the ConnectX-8 to operate in multiplane mode. | |
Keywords: Port split, Quantum-3 | |
Detected in version: 40.44.0212 | |
4230775 | Description: Due to a known issue, telemetry rate must be set to lower than 3 minutes. |
Workaround: N/A | |
Keywords: Telemetry rate | |
Detected in version: 40.44.0212 | |
4230775 | Description: |
Workaround: N/A | |
Keywords: | |
Detected in version: 40.44.0212 | |
4208960 | Description: A packet may be parsed incorrectly, if a driver uses the |
Workaround: Insert the | |
Keywords: PARSE GRAPH NODE, Flex Parser | |
Detected in version: 40.44.0208 | |
4201405 | Description: Upgrading to firmware 40.44.0xxx from any previous Engineering Sample version requires power cycling the driver and not just resetting it (using mlxfwreset). |
Workaround: N/A | |
Keywords: Upgrade, power cycle, reset | |
Detected in version: 40.44.0208 |