What can I help you with?
NVIDIA Firmware Tools (MFT) Documentation v4.31.0-6021

MFT Known Issues

The following table provides a list of known issues and limitations.

Internal Ref. No.

Issue

4397484

Description: mlxlink command displays XDR link speed when it is configured to NDR. This is a presentation issue, not functional.

Workaround: N/A

Keywords: mlxlink, XDR

Discovered in Version: 4.31.0-6012

4038620

Description: Second source cable burn for Windows arm will be enabled as part of GB200 1.1 release.

Workaround: N/A

Keywords: Windows

Discovered in Version: 4.31.0-6006

4294588

Description: In some cases, BlueField-3 users might experience a misleading error message following mlxfwreset command with sync 1 and method 1 (hot reset), even though the reset was completed successfully.

The error message is: "-E- The PCI link is still up even after the expected time (360.0) seconds has passed. Exiting the process."

Workaround: Ignore the misleading error message.

Keywords: mlxfwreset, hot reset

Discovered in Version: 4.31.0-149

4276720

Description: Running mlxreset with flag --skip_fsm_sync shows --E- Sync 2 is not supported.

Workaround: run mlxfwreset -d /dev/mst/mt41692_pciconf0 --sync 1 --skip_fsm_sync -y r.

Keywords: mlxfwreset

Discovered in Version: 4.31.0-149

4258362

Description: When testing the tools using RDMA as the device, they do not work when mst is stopped/started.

Workaround: RDMA rename feature is supported only after running the mst start command.

Keywords: tools, mst, RDMA

Discovered in Version: 4.31.0-149

© Copyright 2025, NVIDIA. Last updated on May 20, 2025.