NVIDIA MLNX_EN Documentation v24.04-0.7.0.0
NVIDIA MLNX_EN Documentation v24.04-0.7.0.0

OVS Offload Using ASAP² Direct

Note

Supported on ConnectX-5 and above adapter cards.

Open vSwitch (OVS) allows Virtual Machines (VMs) to communicate with each other and with the outside world. OVS traditionally resides in the hypervisor and switching is based on twelve tuple matching on flows. The OVS software based solution is CPU intensive, affecting system performance and preventing full utilization of the available bandwidth.
NVIDIA Accelerated Switching And Packet Processing (ASAP2) technology allows OVS offloading by handling OVS data-plane in ConnectX-5 onwards NIC hardware (Embedded Switch or eSwitch) while maintaining OVS control-plane unmodified. As a result, we observe significantly higher OVS performance without the associated CPU load.

As of v5.0, OVS-DPDK became part ofMLNX_EN package. OVS-DPDK supports ASAP2 just as the OVS-Kernel (Traffic Control (TC) kernel-based solution) does, yet with a different set of features.

The traditional ASAP2 hardware data plane is built over SR-IOV virtual functions (VFs), so that the VF is passed through directly to the VM, with the NVIDIA driver running within the VM. An alternate approach that is also supported is vDPA (vhost Data Path Acceleration). vDPA allows the connection to the VM to be established using VirtIO, so that the data-plane is built between the SR-IOV VF and the standard VirtIO driver within the VM, while the control-plane is managed on the host by the vDPA application. Two flavors of vDPA are supported, Software vDPA; and Hardware vDPA. Software vDPA management functionality is embedded into OVS-DPDK, while Hardware vDPA uses a standalone application for management, and can be run with both OVS-Kernel and OVS-DPDK. For further information, please see sections VirtIO Acceleration through VF Relay (Software vDPA) and VirtIO Acceleration through Hardware vDPA.

Install the required packages. For the complete solution, you need to install supporting MLNX_EN(v4.4 and above), iproute2, and openvswitch packages.

Run:

Copy
Copied!
            

./install --ovs-dpdk –upstream-libs

Note

Note that this section applies to both OVS-DPDK and OVS-Kernel similarly.

To set up SR-IOV:

  1. Choose the desired card.

    The example below shows a dual-ported ConnectX-5 card (device ID 0x1017) and a single SR-IOV VF (Virtual Function, device ID 0x1018).

    In SR-IOV terms, the card itself is referred to as the PF (Physical Function).

    Copy
    Copied!
                

    # lspci -nn | grep Mellanox   0a:00.0 Ethernet controller [0200]: Mellanox Technologies MT27800 Family [ConnectX-5] [15b3:1017] 0a:00.1 Ethernet controller [0200]: Mellanox Technologies MT27800 Family [ConnectX-5] [15b3:1017]   0a:00.2 Ethernet controller [0200]: Mellanox Technologies MT27800 Family [ConnectX-5 Virtual Function] [15b3:1018]

    Note

    Enabling SR-IOV and creating VFs is done by the firmware upon admin directive as explained in Step 5 below.

  2. Identify the NVIDIA NICs and locate net-devices which are on the NIC PCI BDF.

    Copy
    Copied!
                

    # ls -l /sys/class/net/ | grep 04:00   lrwxrwxrwx 1 root root 0 Mar 27 16:58 enp4s0f0 -> ../../devices/pci0000:00/0000:00:03.0/0000:04:00.0/net/enp4s0f0 lrwxrwxrwx 1 root root 0 Mar 27 16:58 enp4s0f1 -> ../../devices/pci0000:00/0000:00:03.0/0000:04:00.1/net/enp4s0f1 lrwxrwxrwx 1 root root 0 Mar 27 16:58 eth0 -> ../../devices/pci0000:00/0000:00:03.0/0000:04:00.2/net/eth0 lrwxrwxrwx 1 root root 0 Mar 27 16:58 eth1 -> ../../devices/pci0000:00/0000:00:03.0/0000:04:00.3/net/eth1

    The PF NIC for port #1 is enp4s0f0, and the rest of the commands will be issued on it.

  3. Check the firmware version.
    Make sure the firmware versions installed are as state in the Release Notes document.

    Copy
    Copied!
                

    # ethtool -i enp4s0f0 | head -5 driver: mlx5_core version: 5.0-5  firmware-version: 16.21.0338 expansion-rom-version: bus-info: 0000:04:00.0

  4. Make sure SR-IOV is enabled on the system (server, card).
    Make sure SR-IOV is enabled by the server BIOS, and by the firmware with up to N VFs, where N is the number of VFs required for your environment. Refer to "NVIDIA Firmware Tools" below for more details.

    Copy
    Copied!
                

    # cat /sys/class/net/enp4s0f0/device/sriov_totalvfs 4

  5. Turn ON SR-IOV on the PF device.

    Copy
    Copied!
                

    # echo 2 > /sys/class/net/enp4s0f0/device/sriov_numvfs

  6. Provision the VF MAC addresses using the IP tool.

    Copy
    Copied!
                

    # ip link set enp4s0f0 vf 0 mac e4:11:22:33:44:50 # ip link set enp4s0f0 vf 1 mac e4:11:22:33:44:51

  7. Verify the VF MAC addresses were provisioned correctly and SR-IOV was turned ON.

    Copy
    Copied!
                

    # cat /sys/class/net/enp4s0f0/device/sriov_numvfs 2   # ip link show dev enp4s0f0 256: enp4s0f0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq master ovs-system state UP mode DEFAULT group default qlen 1000 link/ether e4:1d:2d:60:95:a0 brd ff:ff:ff:ff:ff:ff vf 0 MAC e4:11:22:33:44:50, spoof checking off, link-state auto vf 1 MAC e4:11:22:33:44:51, spoof checking off, link-state auto

    In the example above, the maximum number of possible VFs supported by the firmware is 4 and only 2 are enabled.

  8. Provision the PCI VF devices to VMs using PCI Pass-Through or any other preferred virt tool of choice, e.g virt-manager.

For further information on SR-IOV, refer to HowTo Configure SR-IOV for ConnectX-4/ConnectX-5/ConnectX-6 with KVM (Ethernet).

OVS-Kernel Hardware Offloads

SwitchDev Configuration

  1. Unbind the VFs.

    Copy
    Copied!
                

    echo 0000:04:00.2 > /sys/bus/pci/drivers/mlx5_core/unbind echo 0000:04:00.3 > /sys/bus/pci/drivers/mlx5_core/unbind

    Note

    VMs with attached VFs must be powered off to be able to unbind the VFs.

  2. Change the eSwitch mode from Legacy to SwitchDev on the PF device.
    This will also create the VF representor netdevices in the host OS.

    Copy
    Copied!
                

    # devlink dev eswitch set pci/0000:3b:00.0 mode switchdev

    Note

    Before changing the mode, make sure that all VFs are unbound.

    Note

    To go back to SR-IOV legacy mode, run:
    # devlink dev eswitch set pci/0000:3b:00.0 mode legacy
    This will also remove the VF representor netdevices.

    On old OSs or kernels that do not support Devlink, moving to SwitchDev mode can be done using sysfs.

    Copy
    Copied!
                

    # echo switchdev > /sys/class/net/enp4s0f0/compat/devlink/mode

  3. At this stage, VF representors have been created. To map representor to its VF, make sure to obtain the representor's switchid and portname from:

    Copy
    Copied!
                

    # ip -d link show eth4 41: enp0s8f0_1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP mode DEFAULT group default qlen 1000 link/ether ba:e6:21:37:bc:d4 brd ff:ff:ff:ff:ff:ff promiscuity 0 addrgenmode eui64 numtxqueues 10 numrxqueues 10 gso_max_size 65536 gso_max_segs 65535 portname pf0vf1 switchid f4ab580003a1420c

    switchid - used to map representor to device, both device PFs have the same switchid.
    portname - used to map representor to PF and VF, value returned is pfXvfY, where X is the PF number and Y is the number of VF.
    On old kernels, switchid and portname can be acquired through sysfs:

  4. Bind the VFs.

    Copy
    Copied!
                

    echo 0000:04:00.2 > /sys/bus/pci/drivers/mlx5_core/bind echo 0000:04:00.3 > /sys/bus/pci/drivers/mlx5_core/bind

SwitchDev Performance Tuning

SwitchDev performance can be further improved by tuning it.

Steering Mode

OVS-kernel supports two steering modes for rules insertion into hardware.

  1. SMFS – Software Managed Flow Steering (as of MLNX_OFED v5.1, this is the default mode)

    Rules are inserted directly to the hardware by the software (driver). This mode is optimized for rules insertion.

  2. DMFS – Device Managed Flow Steering

    Rules insertion is done using firmware commands. This mode is optimized for throughput with a small amount of rules in the system.

    The mode can be controlled via sysfs or devlink API in kernels that support it:

    Copy
    Copied!
                

    Sysfs: # echo smfs > /sys/class/net/<PF netdev>/compat/devlink/steering_mode   Devlink: # devlink dev param set pci/0000:00:08.0 name flow_steering_mode value "smfs" cmode runtime   Replace smfs param with dmfs for device managed flow steering

Notes:

  • The mode should be set prior to moving to SwitchDev, by echoing to the sysfs or invoking the devlink command.

  • Only when moving to SwitchDev will the driver use the mode set by the previous step.

  • Mode cannot be changed after moving to SwitchDev.

  • The steering mode is applicable for SwitchDev mode only, meaning it does not affect legacy SR-IOV or other configurations.

Troubleshooting SMFS

mlx5 debugfs was extended to support presenting Software Steering resources:
dr_domain including it's tables, matchers and rules.
The interface is read-only.

While dump is being created, new steering rules cannot be inserted/deleted.
The steering information is dumped in the CSV form with the following format: <object_type>,<object_ID>, <object_info>,...,<object_info>

This data can be read at the following path: /sys/kernel/debug/mlx5/<BDF>/steering/fdb/<domain_handle>

Example:

Copy
Copied!
            

    # cat /sys/kernel/debug/mlx5/0000:82:00.0/steering/fdb/dmn_000018644     3100,0x55caa4621c50,0xee802,4,65533     3101,0x55caa4621c50,0xe0100008


You can then use the steering dump parser to make the output more human readable.
The parser can be found in the following public GitHub repository: https://github.com/Mellanox/mlx_steering_dump

vPort Match Mode

OVS-kernel support two modes that define how the rules on match on vport.

  1. Metadata – rules match on metadata instead of vport number (default mode).

    This mode is needed in order to support SR-IOV Live migration and Dual port RoCE features.

    Matching on Metadata can have a performance impact.

  2. Legacy – rules match on vport number.

    In this mode, performance can be higher in comparison to Metadata. It can still be used only if none of the above features (SR-IOV Live migration and Dual port RoCE) is enabled/used.

    The mode can be controlled via sysfs:

    Copy
    Copied!
                

    Set Legacy: # echo legacy > /sys/class/net/<PF netdev>/compat/devlink/vport_match_mode   Set metadata: Devlink: # echo metadata > /sys/class/net/<PF netdev>/compat/devlink/vport_match_mode

    Note: This mode should be set prior to moving to SwitchDev, by echoing to the sysfs.

Flow Table Large Group Number

Offloaded flows, including Connection Tracking, are added to Virtual Switch Forwarding Data Base (FDB) flow tables. FDB tables have a set of flow groups, where each flow group saves the same traffic pattern flows. E.g, for connection tracking offloaded flow, TCP and UDP are different traffic patterns which will end up in two different flow groups.

A flow group has a limited size to save flow entries. As default, the driver has 15 big FDB flow groups. Each of these big flow groups can save 4M / ( 15 + 1) = 256k different 5-tuple flow entries at most. For scenarios with more than 15 traffic patterns, the driver provides a module parameter (num_of_groups) to allow customization and performance tuning.

The mode can be controlled via module param or devlink API for kernels that support it:

Copy
Copied!
            

Module param: # echo <num_of_groups> > /sys/module/mlx5_core/parameters/num_of_groups   Devlink: # devlink dev param set pci/0000:82:00.0 name fdb_large_groups \ cmode driverinit value 20

Notes:

  • In MLNX_OFED v5.1, the default value was changed from 4 to 15.

  • The change takes effect immediately if there is no flow inside the FDB table (no traffic running and all offloaded flows are aged out). And it can be dynamically changed without reloading the driver.
    If there are still offloaded flows residual when changing this parameter, it will only take effect after all flows have aged out.

Open vSwitch Configuration

Open vSwitch configuration is a simple OVS bridge configuration with SwitchDev.

  1. Run the openvswitch service.

    Copy
    Copied!
                

    # systemctl start openvswitch

  2. Create an OVS bridge (here it's named ovs-sriov).

    Copy
    Copied!
                

    # ovs-vsctl add-br ovs-sriov

  3. Enable hardware offload (disabled by default).

    Copy
    Copied!
                

    # ovs-vsctl set Open_vSwitch . other_config:hw-offload=true

  4. Restart the openvswitch service. This step is required for HW offload changes to take effect.

    Copy
    Copied!
                

    # systemctl restart openvswitch

    Note

    HW offload policy can also be changed by setting the tc-policy using one on the following values:

    * none - adds a TC rule to both the software and the hardware (default)

    * skip_sw - adds a TC rule only to the hardware

    * skip_hw - adds a TC rule only to the software

    The above change is used for debug purposes.

  5. Add the PF and the VF representor netdevices as OVS ports.

    Copy
    Copied!
                

    # ovs-vsctl add-port ovs-sriov enp4s0f0 # ovs-vsctl add-port ovs-sriov enp4s0f0_0 # ovs-vsctl add-port ovs-sriov enp4s0f0_1

    Make sure to bring up the PF and representor netdevices.

    Copy
    Copied!
                

    # ip link set dev enp4s0f0 up # ip link set dev enp4s0f0_0 up # ip link set dev enp4s0f0_1 up

    The PF represents the uplink (wire).

    Copy
    Copied!
                

    # ovs-dpctl show system@ovs-system: lookups: hit:0 missed:192 lost:1 flows: 2 masks: hit:384 total:2 hit/pkt:2.00 port 0: ovs-system (internal) port 1: ovs-sriov (internal) port 2: enp4s0f0 port 3: enp4s0f0_0 port 4: enp4s0f0_1

  6. Run traffic from the VFs and observe the rules added to the OVS data-path.

    Copy
    Copied!
                

    # ovs-dpctl dump-flows   recirc_id(0),in_port(3),eth(src=e4:11:22:33:44:50,dst=e4:1d:2d:a5:f3:9d), eth_type(0x0800),ipv4(frag=no), packets:33, bytes:3234, used:1.196s, actions:2   recirc_id(0),in_port(2),eth(src=e4:1d:2d:a5:f3:9d,dst=e4:11:22:33:44:50), eth_type(0x0800),ipv4(frag=no), packets:34, bytes:3332, used:1.196s, actions:3

    In the example above, the ping was initiated from VF0 (OVS port 3) to the outer node (OVS port 2), where the VF MAC is e4:11:22:33:44:50 and the outer node MAC is e4:1d:2d:a5:f3:9d
    As shown above, two OVS rules were added, one in each direction.
    Note that you can also verify offloaded packets by adding type=offloaded to the command. For example:

    Copy
    Copied!
                

    # ovs-appctl dpctl/dump-flows type=offloaded

Open vSwitch Performance Tuning

Flow Aging

The aging timeout of OVS is given in ms and can be controlled using the following command.

Copy
Copied!
            

# ovs-vsctl set Open_vSwitch . other_config:max-idle=30000


TC Policy

Specifies the policy used with HW offloading.

  • none - adds a TC rule to both the software and the hardware (default)

  • skip_sw - adds a TC rule only to the hardware

  • skip_hw - adds a TC rule only to the software

Example:

Copy
Copied!
            

# ovs-vsctl set Open_vSwitch . other_config:tc-policy=skip_sw

Note: TC policy should only be used for debugging purposes.

Max-Revalidator

Specifies the maximum time (in ms) that revalidator threads will wait for kernel statistics before executing flow revalidation.

Copy
Copied!
            

# ovs-vsctl set Open_vSwitch . other_config:max-revalidator=10000


n-handler-threads

Specifies the number of threads for software datapaths to use for handling new flows.
The default value is the number of online CPU cores minus the number of revalidators.

Copy
Copied!
            

# ovs-vsctl set Open_vSwitch . other_config:n-handler-threads=4


n-revalidator-threads

Specifies the number of threads for software datapaths to use for revalidating flows in the datapath.

Copy
Copied!
            

# ovs-vsctl set Open_vSwitch . other_config:n-revalidator-threads=4


vlan-limit

Limits the number of VLAN headers that can be matched to the specified number.

Copy
Copied!
            

# ovs-vsctl set Open_vSwitch . other_config:vlan-limit=2

Basic TC Rules Configuration

Offloading rules can also be added directly, and not only through OVS, using the tc utility.

To create an offloading rule using TC:

  1. Create an ingress qdisc (queueing discipline) for each interface that you wish to add rules into.

    Copy
    Copied!
                

    # tc qdisc add dev enp4s0f0 ingress # tc qdisc add dev enp4s0f0_0 ingress # tc qdisc add dev enp4s0f0_1 ingress

  2. Add TC rules using flower classifier in the following format.

    Copy
    Copied!
                

    # tc filter add dev NETDEVICE ingress protocol PROTOCOL prio PRIORITY \ [chain CHAIN] flower [ MATCH_LIST ] [ action ACTION_SPEC ]

    Note: List of supported matches (specifications) and actions can be found in Classification Fields (Matches) section.

  3. Dump the existing tc rules using flower classifier in the following format.

    Copy
    Copied!
                

    # tc [ -s ] filter show dev NETDEVICE ingress

SR-IOV VF LAG

SR-IOV VF LAG allows the NIC’s physical functions (PFs) to get the rules that the OVS will try to offload to the bond net-device, and to offload them to the hardware e-switch. Bond modes supported are:

  • Active-Backup

  • XOR

  • LACP

SR-IOV VF LAG enables complete offload of the LAG functionality to the hardware. The bonding creates a single bonded PF port. Packets from up-link can arrive from any of the physical ports, and will be forwarded to the bond device.

When hardware offload is used, packets from both ports can be forwarded to any of the VFs. Traffic from the VF can be forwarded to both ports according to the bonding state. Meaning, when in active-backup mode, only one PF is up, and traffic from any VF will go through this PF. When in XOR or LACP mode, if both PFs are up, traffic from any VF will split between these two PFs.

SR-IOV VF LAG Configuration on ASAP2

To enable SR-IOV VF LAG, both physical functions of the NIC should first be configured to SR-IOV SwitchDev mode, and only afterwards bond the up-link representors.

The example below shows the creation of bond interface on two PFs:

  1. Load bonding device and enslave the up-link representor (currently PF) net-device devices.

    Copy
    Copied!
                

    modprobe bonding mode=802.3ad Ifup bond0 (make sure ifcfg file is present with desired bond configuration) ip link set enp4s0f0 master bond0 ip link set enp4s0f1 master bond0

  2. Add the VF representor net-devices as OVS ports. If tunneling is not used, add the bond device as well.

    Copy
    Copied!
                

    ovs-vsctl add-port ovs-sriov bond0 ovs-vsctl add-port ovs-sriov enp4s0f0_0 ovs-vsctl add-port ovs-sriov enp4s0f1_0

  3. Make sure to bring up the PF and the representor netdevices.

    Copy
    Copied!
                

    ip link set dev bond0 up ip link set dev enp4s0f0_0 up ip link set dev enp4s0f1_0 up

Note

Once SR-IOV VF LAG is configured, all VFs of the two PFs will become part of the bond, and will behave as described above.


Limitations

  • In VF LAG mode, outgoing traffic in load balanced mode is according to the origin ring, thus, half of the rings will be coupled with port 1 and half with port 2. All the traffic on the same ring will be sent from the same port.

  • VF LAG configuration is not supported when the NUM_OF_VFS configured in mlxconfig is higher than 64.

Using TC with VF LAG

Both rules can be added using either of the following.

  1. Shared block (supported from kernel 4.16 and RHEL/CentOS 7.7 and above).

    Copy
    Copied!
                

    # tc qdisc add dev bond0 ingress_block 22 ingress # tc qdisc add dev ens4p0 ingress_block 22 ingress # tc qdisc add dev ens4p1 ingress_block 22 ingress

    1. Add drop rule.

      Copy
      Copied!
                  

      # tc filter add block 22 protocol arp parent ffff: prio 3 \ flower \ dst_mac e4:11:22:11:4a:51 \ action drop

    2. Add redirect rule from bond to representor.

      Copy
      Copied!
                  

      # tc filter add block 22 protocol arp parent ffff: prio 3 \ flower \ dst_mac e4:11:22:11:4a:50 \ action mirred egress redirect dev ens4f0_0

    3. Add redirect rule from representor to bond.

      Copy
      Copied!
                  

      # tc filter add dev ens4f0_0 protocol arp parent ffff: prio 3 \ flower \ dst_mac ec:0d:9a:8a:28:42 \ action mirred egress redirect dev bond0

  2. Without shared block (supported from kernel 4.15 and below).

    1. Add redirect rule from bond to representor.

      Copy
      Copied!
                  

      # tc filter add dev bond0 protocol arp parent ffff: prio 1 \ flower \ dst_mac e4:11:22:11:4a:50 \ action mirred egress redirect dev ens4f0_0

    2. Add redirect rule from representor to bond.

      Copy
      Copied!
                  

      # tc filter add dev ens4f0_0 protocol arp parent ffff: prio 3 \ flower \ dst_mac ec:0d:9a:8a:28:42 \ action mirred egress redirect dev bond0

Classification Fields (Matches)

OVS-Kernel supports multiple classification fields which packets can fully or partially match.

Ethernet Layer 2

  • Destination MAC

  • Source MAC

  • Ethertype

Supported on all kernels.

In OVS dump flows:

Copy
Copied!
            

skb_priority(0/0),skb_mark(0/0),in_port(eth6),eth(src=00:02:10:40:10:0d ,dst=68:54:ed:00:af:de),eth_type(0x8100), packets:1981, bytes:206024, used:0.440s, dp:tc, actions:eth7

Using TC rules:

Copy
Copied!
            

tc filter add dev $rep parent ffff: protocol arp pref 1 \ flower \ dst_mac e4:1d:2d:5d:25:35 \ src_mac e4:1d:2d:5d:25:34 \ action mirred egress redirect dev $NIC


IPv4/IPv6

  • Source address

  • Destination address

  • Protocol

    • TCP/UDP/ICMP/ICMPv6

  • TOS

  • TTL (HLIMIT)

Supported on all kernels.

In OVS dump flows:

Copy
Copied!
            

Ipv4: ipv4(src=0.0.0.0/0.0.0.0,dst=0.0.0.0/0.0.0.0,proto=17,tos=0/0,ttl=0/0,frag=no) Ipv6: ipv6(src=::/::,dst=1:1:1::3:1040:1008,label=0/0,proto=58,tclass=0/0x3,hlimit=64),

Using TC rules:

Copy
Copied!
            

IPv4: tc filter add dev $rep parent ffff: protocol ip pref 1 \ flower \ dst_ip 1.1.1.1 \ src_ip 1.1.1.2 \ ip_proto TCP \ ip_tos 0x3 \ ip_ttl 63 \ action mirred egress redirect dev $NIC     IPv6: tc filter add dev $rep parent ffff: protocol ipv6 pref 1 \ flower \ dst_ip 1:1:1::3:1040:1009 \ src_ip 1:1:1::3:1040:1008 \ ip_proto TCP \ ip_tos 0x3 \ ip_ttl 63\ action mirred egress redirect dev $NIC


TCP/UDP Source and Destination ports & TCP Flags

  • TCP/UDP source and destinations ports

  • TCP flags

Supported kernels are kernel > 4.13 and RHEL > 7.5

In OVS dump flows:

Copy
Copied!
            

TCP: tcp(src=0/0,dst=32768/0x8000), UDP: udp(src=0/0,dst=32768/0x8000), TCP flags: tcp_flags(0/0)

Using TC rules:

Copy
Copied!
            

tc filter add dev $rep parent ffff: protocol ip pref 1 \ flower \ ip_proto TCP \ dst_port 100 \ src_port 500 \ tcp_flags 0x4/0x7 \ action mirred egress redirect dev $NIC


VLAN

  • ID

  • Priority

  • Inner vlan ID and Priority

Supported kernels: All (QinQ: kernel 4.19 and higher, and RHEL 7.7 and higher)

In OVS dump flows:

Copy
Copied!
            

eth_type(0x8100),vlan(vid=2347,pcp=0),

Using TC rules:

Copy
Copied!
            

tc filter add dev $rep parent ffff: protocol 802.1Q pref 1 \ flower \ vlan_ethtype 0x800 \ vlan_id 100 \ vlan_prio 0 \ action mirred egress redirect dev $NIC QinQ: tc filter add dev $rep parent ffff: protocol 802.1Q pref 1 \ flower \ vlan_ethtype 0x8100 \ vlan_id 100 \ vlan_prio 0 \ cvlan_id 20 \ cvlan_prio 0 \ cvlan_ethtype 0x800 \ action mirred egress redirect dev $NIC


Tunnel

  • ID (Key)

  • Source IP address

  • Destination IP address

  • Destination port

  • TOS (supported from kernel 4.19 and above & RHEL 7.7 and above)

  • TTL (support from kernel 4.19 and above & RHEL 7.7 and above)

  • Tunnel options (Geneve)

Supported kernels:

  • VXLAN: All

  • GRE: Kernel > 5.0, RHEL 7.7 and above

  • Geneve: Kernel > 5.0, RHEL 7.7 and above

In OVS dump flows:

Copy
Copied!
            

tunnel(tun_id=0x5,src=121.9.1.1,dst=131.10.1.1,ttl=0/0,tp_dst=4789,flags(+key))

Using TC rules:

Copy
Copied!
            

# tc filter add dev $rep protocol 802.1Q parent ffff: pref 1  flower \ vlan_ethtype 0x800 \ vlan_id 100 \ vlan_prio 0 \ action mirred egress redirect dev $NIC QinQ: # tc filter add dev vxlan100 protocol ip parent ffff: \ flower \ skip_sw \ dst_mac e4:11:22:11:4a:51 \ src_mac e4+:11:22:11:4a:50 \ enc_src_ip 20.1.11.1 \ enc_dst_ip 20.1.12.1 \ enc_key_id 100 \ enc_dst_port 4789 \ action tunnel_key unset \ action mirred egress redirect dev ens4f0_0

Supported Actions

Forward

Forward action allows for packet redirection:

  • From VF to wire

  • Wire to VF

  • VF to VF

Supported on all kernels.

In OVS dump flows:

Copy
Copied!
            

skb_priority(0/0),skb_mark(0/0),in_port(eth6),eth(src=00:02:10:40:10:0d ,dst=68:54:ed:00:af:de),eth_type(0x8100), packets:1981, bytes:206024, used:0.440s, dp:tc, actions:eth7

Using TC rules:

Copy
Copied!
            

tc filter add dev $rep parent ffff: protocol arp pref 1 \ flower \ dst_mac e4:1d:2d:5d:25:35 \ src_mac e4:1d:2d:5d:25:34 \ action mirred egress redirect dev $NIC


Drop

Drop action allows to drop incoming packets.

Supported on all kernels.

In OVS dump flows:

Copy
Copied!
            

skb_priority(0/0),skb_mark(0/0),in_port(eth6),eth(src=00:02:10:40:10:0d ,dst=68:54:ed:00:af:de),eth_type(0x8100), packets:1981, bytes:206024, used:0.440s, dp:tc, actions:drop

Using TC rules:

Copy
Copied!
            

tc filter add dev $rep parent ffff: protocol arp pref 1 \ flower \ dst_mac e4:1d:2d:5d:25:35 \ src_mac e4:1d:2d:5d:25:34 \ action drop


Statistics

By default, each flow collects the following statistics:

  • Packets – number of packets which hit the flow

  • Bytes – total number of bytes which hit the flow

  • Last used – the amount of time passed since last packet hit the flow

Supported on all kernels.

In OVS dump flows:

Copy
Copied!
            

skb_priority(0/0),skb_mark(0/0),in_port(eth6),eth(src=00:02:10:40:10:0d ,dst=68:54:ed:00:af:de),eth_type(0x8100), packets:1981, bytes:206024, used:0.440s, dp:tc, actions:drop

Using TC rules:

Copy
Copied!
            

#tc -s filter show dev $rep ingress   filter protocol ip pref 2 flower chain 0 filter protocol ip pref 2 flower chain 0 handle 0x2 eth_type ipv4 ip_proto tcp src_ip 192.168.140.100 src_port 80 skip_sw in_hw action order 1: mirred (Egress Redirect to device p0v11_r) stolen index 34 ref 1 bind 1 installed 144 sec used 0 sec Action statistics: Sent 388344 bytes 2942 pkt (dropped 0, overlimits 0 requeues 0) backlog 0b 0p requeues 0 

Tunnels (Encapsulation/Decapsulation)

OVS-kernel supports offload of tunnels using encapsulation and decapsulation actions.

  • Encapsulation – pushing of tunnel header is supported on Tx

  • Decapsulation – popping of tunnel header is supported on Rx

Supported Tunnels:

  • VXLAN (IPv4/IPv6) – supported on all Kernels

  • GRE (IPv4/IPv6) – supported on kernel 5.0 and above & RHEL 7.6 and above

  • Geneve (IPv4/IPv6) - supported on kernel 5.0 and above & RHEL 7.6 and above

OVS configuration:
In case of offloading tunnel, the PF/bond should not be added as a port in the OVS datapath. It should rather be assigned with the IP address to be used for encapsulation.
The example below shows two hosts (PFs) with IPs 1.1.1.177 and 1.1.1.75, where the PF device on both hosts is enp4s0f0, and the VXLAN tunnel is set with VNID 98:

  • On the first host:

    Copy
    Copied!
                

    # ip addr add 1.1.1.177/24 dev enp4s0f1   # ovs-vsctl add-port ovs-sriov vxlan0 -- set interface vxlan0 type=vxlan options:local_ip=1.1.1.177 options:remote_ip=1.1.1.75 options:key=98

  • On the second host:

    Copy
    Copied!
                

    # ip addr add 1.1.1.75/24 dev enp4s0f1   # ovs-vsctl add-port ovs-sriov vxlan0 -- set interface vxlan0 type=vxlan options:local_ip=1.1.1.75 options:remote_ip=1.1.1.177 options:key=98     • for GRE IPv4 tunnel need use type=gre • for GRE IPv6 tunnel need use type=ip6gre • for GENEVE tunnel need use type=geneve

Note

When encapsulating guest traffic, the VF’s device MTU must be reduced to allow the host/HW to add the encap headers without fragmenting the resulted packet. As such, the VF’s MTU must be lowered by 50 bytes from the uplink MTU for IPv4 and 70 bytes for IPv6.

Tunnel offload using TC rules:

Copy
Copied!
            

Encapsulation: # tc filter add dev ens4f0_0 protocol 0x806 parent ffff: \ flower \ skip_sw \ dst_mac e4:11:22:11:4a:51 \ src_mac e4:11:22:11:4a:50 \ action tunnel_key set \ src_ip 20.1.12.1 \ dst_ip 20.1.11.1 \ id 100 \ action mirred egress redirect dev vxlan100   Decapsulation: # tc filter add dev vxlan100 protocol 0x806 parent ffff: \ flower \ skip_sw \ dst_mac e4:11:22:11:4a:51 \ src_mac e4:11:22:11:4a:50 \ enc_src_ip 20.1.11.1 \ enc_dst_ip 20.1.12.1 \ enc_key_id 100 \ enc_dst_port 4789 \ action tunnel_key unset \ action mirred egress redirect dev ens4f0_0


VLAN Push/Pop

OVS-kernel supports offload of vlan header push/pop actions.

  • Push—pushing of VLAN header is supported on Tx

  • Pop—popping of tunnel header is supported on Rx

Note

Starting with ConnectX-6 Dx hardware models and above, pushing of VLAN header is also supported on Rx, and popping of VLAN header is also supported on Tx.

OVS Configuration

Add a tag=$TAG section for the OVS command line that adds the representor ports. For example, VLAN ID 52 is being used here.

Copy
Copied!
            

# ovs-vsctl add-port ovs-sriov enp4s0f0 # ovs-vsctl add-port ovs-sriov enp4s0f0_0 tag=52 # ovs-vsctl add-port ovs-sriov enp4s0f0_1 tag=52

The PF port should not have a VLAN attached. This will cause OVS to add VLAN push/pop actions when managing traffic for these VFs.

Dump Flow Example

Copy
Copied!
            

recirc_id(0),in_port(3),eth(src=e4:11:22:33:44:50,dst=00:02:c9:e9:bb:b2),eth_type(0x0800),ipv4(frag=no), \ packets:0, bytes:0, used:never, actions:push_vlan(vid=52,pcp=0),2   recirc_id(0),in_port(2),eth(src=00:02:c9:e9:bb:b2,dst=e4:11:22:33:44:50),eth_type(0x8100), \ vlan(vid=52,pcp=0),encap(eth_type(0x0800),ipv4(frag=no)), packets:0, bytes:0, used:never, actions:pop_vlan,3

VLAN Offload using TC Rules Example

Copy
Copied!
            

# tc filter add dev ens4f0_0 protocol ip parent ffff: \ flower \ skip_sw \ dst_mac e4:11:22:11:4a:51 \ src_mac e4:11:22:11:4a:50 \ action vlan push id 100 \ action mirred egress redirect dev ens4f0   # tc filter add dev ens4f0 protocol 802.1Q parent ffff: \ flower \ skip_sw \ dst_mac e4:11:22:11:4a:51 \ src_mac e4:11:22:11:4a:50 \ vlan_ethtype 0x800 \ vlan_id 100 \ vlan_prio 0 \ action vlan pop \ action mirred egress redirect dev ens4f0_0


TC Configuration for ConnectX-6 Dx and Above

Example of VLAN Offloading with popping header on Tx and pushing on Rx using TC Rules:

Copy
Copied!
            

# tc filter add dev ens4f0_0 ingress protocol 802.1Q parent ffff: \        flower \                vlan_id 100 \        action vlan pop \        action tunnel_key set \                src_ip 4.4.4.1 \                dst_ip 4.4.4.2 \                dst_port 4789 \                id 42 \        action mirred egress redirect dev vxlan0   # tc filter add dev vxlan0 ingress protocol all parent ffff: \        flower \                enc_dst_ip 4.4.4.1 \                enc_src_ip 4.4.4.2 \                enc_dst_port 4789 \                enc_key_id 42 \        action tunnel_key unset \        action vlan push id 100 \         action mirred egress redirect dev ens4f0_0

Header Rewrite

This action allows for modifying packet fields.

Ethernet Layer 2

  • Destination MAC

  • Source MAC

Supported kernels: Kernel 4.14 and above & RHEL 7.5 and above

In OVS dump flows:

Copy
Copied!
            

skb_priority(0/0),skb_mark(0/0),in_port(eth6),eth(src=00:02:10:40:10:0d ,dst=68:54:ed:00:af:de),eth_type(0x8100), packets:1981, bytes:206024, used:0.440s, dp:tc, actions: set(eth(src=68:54:ed:00:f4:ab,dst=fa:16:3e:dd:69:c4)),eth7

Using TC rules:

Copy
Copied!
            

tc filter add dev $rep parent ffff: protocol arp pref 1 \ flower \ dst_mac e4:1d:2d:5d:25:35 \ src_mac e4:1d:2d:5d:25:34 \ action pedit ex \ munge eth dst set 20:22:33:44:55:66 \ munge eth src set aa:ba:cc:dd:ee:fe \ action mirred egress redirect dev $NIC


IPv4/IPv6

  • Source address

  • Destination address

  • Protocol

  • TOS

  • TTL (HLIMIT)

Supported kernels: Kernel 4.14 and above & RHEL 7.5 and above

In OVS dump flows:

Copy
Copied!
            

Ipv4: set(eth(src=de:e8:ef:27:5e:45,dst=00:00:01:01:01:01)), set(ipv4(src=10.10.0.111,dst=10.20.0.122,ttl=63)) Ipv6: set(ipv6(dst=2001:1:6::92eb:fcbe:f1c8,hlimit=63)),

Using TC rules:

Copy
Copied!
            

IPv4: tc filter add dev $rep parent ffff: protocol ip pref 1 \ flower \ dst_ip 1.1.1.1 \ src_ip 1.1.1.2 \ ip_proto TCP \ ip_tos 0x3 \ ip_ttl 63 \ pedit ex \ munge ip src set 2.2.2.1 \ munge ip dst set 2.2.2.2 \ munge ip tos set 0 \ munge ip ttl dec \ action mirred egress redirect dev $NIC     IPv6: tc filter add dev $rep parent ffff: protocol ipv6 pref 1 \ flower \ dst_ip 1:1:1::3:1040:1009 \ src_ip 1:1:1::3:1040:1008 \ ip_proto tcp \ ip_tos 0x3 \ ip_ttl 63\ pedit ex \ munge ipv6 src set 2:2:2::3:1040:1009 \ munge ipv6 dst set 2:2:2::3:1040:1008 \ munge ipv6 hlimit dec \ action mirred egress redirect dev $NIC

Note

IPv4 and IPv6 header rewrite is only supported with match on UDP/TCP/ICMP protocols.

TCP/UDP Source and Destination Ports

  • TCP/UDP source and destinations ports

Supported kernels: kernel > 4.16 & RHEL > 7.6

In OVS dump flows:

Copy
Copied!
            

TCP: set(tcp(src= 32768/0xffff,dst=32768/0xffff)), UDP:   set(udp(src= 32768/0xffff,dst=32768/0xffff)),

Using TC rules:

Copy
Copied!
            

TCP:   tc filter add dev $rep parent ffff: protocol ip pref 1 \ flower \ dst_ip 1.1.1.1 \ src_ip 1.1.1.2 \ ip_proto tcp \ ip_tos 0x3 \ ip_ttl 63 \ pedit ex \ pedit ex munge ip tcp sport set 200 pedit ex munge ip tcp dport set 200 action mirred egress redirect dev $NIC   UDP: tc filter add dev $rep parent ffff: protocol ip pref 1 \ flower \ dst_ip 1.1.1.1 \ src_ip 1.1.1.2 \ ip_proto udp \ ip_tos 0x3 \ ip_ttl 63 \ pedit ex \ pedit ex munge ip udp sport set 200 pedit ex munge ip udp dport set 200 action mirred egress redirect dev $NIC


VLAN

  • ID

Supported on all kernels.

In OVS dump flows:

Copy
Copied!
            

Set(vlan(vid=2347,pcp=0/0)),

Using TC rules:

Copy
Copied!
            

tc filter add dev $rep parent ffff: protocol 802.1Q pref 1 \ flower \ vlan_ethtype 0x800 \ vlan_id 100 \ vlan_prio 0 \ action vlan modify id 11 pipe action mirred egress redirect dev $NIC

Connection Tracking

The TC connection tracking action performs connection tracking lookup by sending the packet to netfilter conntrack module. Newly added connections may be associated, via the ct commit action, with a 32 bit mark, 128 bit label and source/destination NAT values.

The following example allows ingress tcp traffic from the uplink representor to vf1_rep, while assuring that egress traffic from vf1_rep is only allowed on established connections. In addition, mark and source IP NAT is applied.

In OVS dump flows:

Copy
Copied!
            

ct(zone=2,nat) ct_state(+est+trk) actions:ct(commit,zone=2,mark=0x4/0xffffffff,nat(src=5.5.5.5))

Using TC rules:

Copy
Copied!
            

# tc filter add dev $uplink_rep ingress chain 0 prio 1 proto ip \ flower \ ip_proto tcp \ ct_state -trk \ action ct zone 2 nat pipe action goto chain 2 # tc filter add dev $uplink_rep ingress chain 2 prio 1 proto ip \ flower \ ct_state +trk+new \ action ct zone 2 commit mark 0xbb nat src addr 5.5.5.7 pipe \ action mirred egress redirect dev $vf1_rep # tc filter add dev $uplink_rep ingress chain 2 prio 1 proto ip \ flower \ ct_zone 2 \ ct_mark 0xbb \ ct_state +trk+est \ action mirred egress redirect dev $vf1_rep   #Setup filters on $vf1_rep, allowing only established connections of zone 2 through, and reverse nat (dst nat in this case) # tc filter add dev $vf1_rep ingress chain 0 prio 1 proto ip \ flower \ ip_proto tcp \ ct_state -trk \ action ct zone 2 nat pipe \ action goto chain 1 # tc filter add dev $vf1_rep ingress chain 1 prio 1 proto ip \ flower \ ct_zone 2 \ ct_mark 0xbb \ ct_state +trk+est \ action mirred egress redirect dev eth0

Connection Tracking Performance Tuning

  • Max offloaded connections—specifies the limit on the number of offloaded connections.
    Example:

    Copy
    Copied!
                

    # devlink dev param set pci/${pci_dev} name ct_max_offloaded_conns value $max cmode runtime

  • Allow mixed NAT/non-NAT CT—allows offloading of the following scenario:

    Copy
    Copied!
                

    • cookie=0x0, duration=21.843s, table=0, n_packets=4838718, n_bytes=241958846, ct_state=-trk,ip,in_port=enp8s0f0 actions=ct(table=1,zone=2) • cookie=0x0, duration=21.823s, table=1, n_packets=15363, n_bytes=773526, ct_state=+new+trk,ip,in_port=enp8s0f0 actions=ct(commit,zone=2,nat(dst=11.11.11.11)),output:"enp8s0f0_1" • cookie=0x0, duration=21.806s, table=1, n_packets=4767594, n_bytes=238401190, ct_state=+est+trk,ip,in_port=enp8s0f0 actions=ct(zone=2,nat),output:"enp8s0f0_1"

    Example:

    Copy
    Copied!
                

    # echo enable > /sys/class/net/<device>/compat/devlink/ct_action_on_nat_conns

Forward to Chain (TC Only)

TC interface supports adding flows on different chains. Only chain 0 is accessed by default. Access to the other chains requires usafe of the goto action.

In this example, a flow is created on chain 1 without any match and redirect to wire.

The second flow is created on chain 0 and match on source MAC and action goto chain 1.

This example simulates simple MAC spoofing.

Copy
Copied!
            

#tc filter add dev $rep parent ffff: protocol all chain 1 pref 1 \ flower \ action mirred egress redirect dev $NIC   #tc filter add dev $rep parent ffff: protocol all chain 1 pref 1 \ flower \ src_mac aa:bb:cc:aa:bb:cc action goto chain 1

Port Mirroring (Flow Based VF Traffic Mirroring for ASAP²)

Unlike para-virtual configurations, when the VM traffic is offloaded to the hardware via SR-IOV VF, the host side Admin cannot snoop the traffic (e.g. for monitoring).

ASAP² uses the existing mirroring support in OVS and TC along with the enhancement to the offloading logic in the driver to allow mirroring the VF traffic to another VF.

The mirrored VF can be used to run traffic analyzer (tcpdump, wireshark, etc) and observe the traffic of the VF being mirrored.

The example below shows the creation of port mirror on the following configuration:

Copy
Copied!
            

# ovs-vsctl show 09d8a574-9c39-465c-9f16-47d81c12f88a Bridge br-vxlan Port "enp4s0f0_1" Interface "enp4s0f0_1" Port "vxlan0" Interface "vxlan0" type: vxlan options: {key="100", remote_ip="192.168.1.14"} Port "enp4s0f0_0" Interface "enp4s0f0_0" Port "enp4s0f0_2" Interface "enp4s0f0_2" Port br-vxlan Interface br-vxlan type: internal ovs_version: "2.14.1"

  • To set enp4s0f0_0 as the mirror port, and mirror all of the traffic:

    Copy
    Copied!
                

    # ovs-vsctl -- --id=@p get port enp4s0f0_0 \ -- --id=@m create mirror name=m0 select-all=true output-port=@p \ -- set bridge br-vxlan mirrors=@m

  • To set enp4s0f0_0 as the mirror port, and only mirror the traffic, the destination is enp4s0f0_1:

    Copy
    Copied!
                

    # ovs-vsctl -- --id=@p1 get port enp4s0f0_0 \ -- --id=@p2 get port enp4s0f0_1 \ -- --id=@m create mirror name=m0 select-dst-port=@p2 output-port=@p1 \ -- set bridge br-vxlan mirrors=@m

  • To set enp4s0f0_0 as the mirror port, and only mirror the traffic the source is enp4s0f0_1:

    Copy
    Copied!
                

    # ovs-vsctl -- --id=@p1 get port enp4s0f0_0 \ -- --id=@p2 get port enp4s0f0_1 \ -- --id=@m create mirror name=m0 select-src-port=@p2 output-port=@p1 \ -- set bridge br-vxlan mirrors=@m

  • To set enp4s0f0_0 as the mirror port and mirror, all the traffic on enp4s0f0_1:

    Copy
    Copied!
                

    # ovs-vsctl -- --id=@p1 get port enp4s0f0_0 \ -- --id=@p2 get port enp4s0f0_1 \ -- --id=@m create mirror name=m0 select-dst-port=@p2 select-src-port=@p2 output-port=@p1 \ -- set bridge br-vxlan mirrors=@m

To clear the mirror port:

Copy
Copied!
            

# ovs-vsctl clear bridge br-vxlan mirrors

Mirroring using TC:

Copy
Copied!
            

Mirror to VF tc filter add dev $rep parent ffff: protocol arp pref 1 \ flower \ dst_mac e4:1d:2d:5d:25:35 \ src_mac e4:1d:2d:5d:25:34 \ action mirred egress mirror dev $mirror_rep pipe \ action mirred egress redirect dev $NIC   Mirror to tunnel: tc filter add dev $rep parent ffff: protocol arp pref 1 \ flower \ dst_mac e4:1d:2d:5d:25:35 \ src_mac e4:1d:2d:5d:25:34 \ action tunnel_key set \ src_ip 1.1.1.1 \ dst_ip 1.1.1.2 \ dst_port 4789 \ id 768 \ pipe \ action mirred egress mirror dev vxlan100 pipe \ action mirred egress redirect dev $NIC

Forward to Multiple Destinations

Forward to up 32 destinations (representors and tunnels) is supported using TC.

Example 1: forward to 32 VFs.

Copy
Copied!
            

tc filter add dev $NIC parent ffff: protocol arp pref 1 \                        flower \                        dst_mac e4:1d:2d:5d:25:35 \                        src_mac e4:1d:2d:5d:25:34 \                        action mirred egress mirror dev $rep0 pipe \                        action mirred egress mirror dev $rep1 pipe \ ...                        action mirred egress mirror dev $rep30 pipe \                         action mirred egress redirect dev $rep31

Example 2: forward to 16 tunnels.

Copy
Copied!
            

tc filter add dev $rep parent ffff: protocol arp pref 1 \                        flower \                        dst_mac e4:1d:2d:5d:25:35 \                        src_mac e4:1d:2d:5d:25:34 \                        action tunnel_key set src_ip $ip_src dst_ip $ip_dst \ dst_port 4789 id 0 nocsum \ pipe action mirred egress mirror dev vxlan0 pipe \                        action tunnel_key set src_ip $ip_src dst_ip $ip_dst \ dst_port 4789 id 1 nocsum \ pipe action mirred egress mirror dev vxlan0 pipe \ ...                        action tunnel_key set src_ip $ip_src dst_ip $ip_dst \ dst_port 4789 id 15 nocsum \ pipe action mirred egress redirect dev vxlan0

Note
  • TC supports up to 32 actions

  • If header rewrite is used, then all destinations should have the same header rewrite

  • If VLAN push/pop is used, then all destinations should have the same VLAN ID and actions


sFLOW

This feature allows for monitoring traffic sent between two VMs on the same host using an sFlow collector.

The example below assumes the environment is configured as described below.

Copy
Copied!
            

# ovs-vsctl show 09d8a574-9c39-465c-9f16-47d81c12f88a Bridge br-vxlan Port "enp4s0f0_1"  Interface "enp4s0f0_1" Port "vxlan0" Interface "vxlan0" type: vxlan options: {key="100", remote_ip="192.168.1.14"} Port "enp4s0f0_0" Interface "enp4s0f0_0"  Port "enp4s0f0_2" Interface "enp4s0f0_2"  Port br-vxlan Interface br-vxlan type: internal ovs_version: "2.14.1"

To sample all traffic over the OVS bridge:

Copy
Copied!
            

# ovs-vsctl -- --id=@sflow create sflow agent=\"$SFLOW_AGENT\" \ target=\"$SFLOW_TARGET:$SFLOW_PORT\" header=$SFLOW_HEADER \ sampling=$SFLOW_SAMPLING polling=10 \ -- set bridge br-vxlan sflow=@sflow

Parameter

Description

SFLOW_AGENT

Indicates that the sFlow agent should send traffic from SFLOW_AGENT’s IP address

SFLOW_TARGET

Remote IP address of the sFLOW collector

SFLOW_HEADER

Size of packet header to sample (in bytes)

SFLOW_SAMPLING

Sample rate

To clear the sFLOW configuration:

Copy
Copied!
            

# ovs-vsctl clear bridge br-vxlan sflow

To list the sFLOW configuration:

Copy
Copied!
            

# ovs-vsctl list sflow

sFLOW using TC:

Copy
Copied!
            

Sample to VF tc filter add dev $rep parent ffff: protocol arp pref 1 \ flower \ dst_mac e4:1d:2d:5d:25:35 \ src_mac e4:1d:2d:5d:25:34 \ action sample rate 10 group 5 trunc 96 \ action mirred egress redirect dev $NIC

Note

Userspace application is needed in order to process to sampled packet from the kernel. Example: https://github.com/Mellanox/libpsample

Rate Limit

OVS-kernel supports offload of VF rate limit using OVS configuration and TC.

The example below sets a rate limit to the VF related to representor eth0 to 10Mbps.

Copy
Copied!
            

OVS: # ovs-vsctl set interface eth0 ingress_policing_rate=10000   tc: # tc_filter add dev eth0 root prio 1 protocol ip matchall skip_sw action police rate 10mbit burst 20k


Kernel Requirements

This kernel config should be enabled in order to support switchdev offload.

  • CONFIG_NET_ACT_CSUM – needed for action csum

  • CONFIG_NET_ACT_PEDIT – needed for header rewrite

  • CONFIG_NET_ACT_MIRRED – needed for basic forward

  • CONFIG_NET_ACT_CT – needed for connection tracking (supported from kernel 5.6)

  • CONFIG_NET_ACT_VLAN - needed for action vlan push/pop

  • CONFIG_NET_ACT_GACT

  • CONFIG_NET_CLS_FLOWER

  • CONFIG_NET_CLS_ACT

  • CONFIG_NET_SWITCHDEV

  • CONFIG_NET_TC_SKB_EXT - needed for connection tracking (supported from kernel 5.6)

  • CONFIG_NET_ACT_CT - needed for connection tracking (supported from kernel 5.6)

  • CONFIG_NFT_FLOW_OFFLOAD

  • CONFIG_NET_ACT_TUNNEL_KEY

  • CONFIG_NF_FLOW_TABLE - needed for connection tracking (supported from kernel 5.6)

  • CONFIG_SKB_EXTENSIONS - needed for connection tracking (supported from kernel 5.6)

  • CONFIG_NET_CLS_MATCHALL

  • CONFIG_NET_ACT_POLICE

  • CONFIG_MLX5_ESWITCH

VF Metering

OVS-kernel supports offloading of VF metering (TX and RX) using sysfs. Metering of number of packets per second (PPS) and bytes per second (BPS) is supported.

The example bellow sets Rx meter on VF 0 with value 10Mbps BPS.

Copy
Copied!
            

echo 10000000 > /sys/class/net/enp4s0f0/device/sriov/0/meters/rx/bps/rate echo 65536 > /sys/class/net/enp4s0f0/device/sriov/0/meters/rx/bps/burst

The example bellow sets Tx meter on VF 0 with value 1000 PPS.

Copy
Copied!
            

echo 1000 > /sys/class/net/enp4s0f0/device/sriov/0/meters/tx/pps/rate echo 100 > /sys/class/net/enp4s0f0/device/sriov/0/meters/tx/pps/burst

Note

Both rate and burst must not be zero and burst may need to be adjusted according to the requirements.

The following counters can be used to query the number dropped packet/bytes:

Copy
Copied!
            

#cat /sys/class/net/enp8s0f0/device/sriov/0/meters/rx/pps/packets_dropped #cat /sys/class/net/enp8s0f0/device/sriov/0/meters/rx/pps/bytes_dropped #cat /sys/class/net/enp8s0f0/device/sriov/0/meters/rx/bps/packets_dropped #cat /sys/class/net/enp8s0f0/device/sriov/0/meters/rx/bps/bytes_dropped #cat /sys/class/net/enp8s0f0/device/sriov/0/meters/tx/pps/packets_dropped #cat /sys/class/net/enp8s0f0/device/sriov/0/meters/tx/pps/bytes_dropped #cat /sys/class/net/enp8s0f0/device/sriov/0/meters/tx/bps/packets_dropped #cat /sys/class/net/enp8s0f0/device/sriov/0/meters/tx/bps/bytes_dropped

Representor Metering

Metering for uplink and VF representors traffic support has been added.

Traffic going to a representor device can be a result of a miss in the embedded switch (eSwitch) FDB tables. This means that a packet which arrived from that representor into the eSwitch was not matched against the existing rules in the hardware FDB tables and needs to be forwarded to software to be handled there and is, therefore, forwarded to the originating representor device driver.

The meter allows to configure the max rate [packets/sec] and max burst [packets] for traffic going to the representor driver. Any traffic exceeding values provided by the user will be dropped in hardware. There are statistics that show number of dropped packets.

The configuration of a representors metering is done via a new sysfs called miss_rl_cfg.

  • Full path of the miss_rl_cfg parameter: /sys/class/net//rep_config/miss_rl_cfg

  • Usage: echo ”<rate> <burst>” > /sys/class/net//rep_config/miss_rl_cfg. Rate is the max rate of packets allowed for this representor (in packets/sec units) and burst is the max burst size allowed for this representor (in packets units). Both values must be specified. The default is 0 for both, meaning unlimited rate and burst.

To view the amount of packets and bytes that were dropped due to traffic exceeding the user-provided rate and burst, two read-only sysfs for statistics are exposed.

  • /sys/class/net//rep_config/miss_rl_dropped_bytes counts how many FDB-miss bytes were dropped due to reaching the miss limits

  • /sys/class/net//rep_config/miss_rl_dropped_packets counts how many FDB-miss packets were dropped due to reaching the miss limits

Open vSwitch Metering

There are two types of meters, kpps (kilobits per second) and pktps(packets per second), which are described in Meter Syntax of OpenFlow 1.3+ Switch Meter Table Commands. OVS-Kernel supports offloading them both.

The example below is to offload a kpps meter. Please follow the steps after doing basic configurations as described in section 5.1.3.

  1. Create OVS meter with a target rate.

    Copy
    Copied!
                

    ovs-ofctl -O OpenFlow13 add-meter ovs-sriov meter=1,kbps,band=type=drop,rate=204800

  2. Delete the default rule.

    Copy
    Copied!
                

    ovs-ofctl del-flows ovs-sriov

  3. Configure OpenFlow rules. Here VF bandwidth on the receiving side will be limited by the rate configured in step 1.

    Copy
    Copied!
                

    ovs-ofctl -O OpenFlow13 add-flow ovs-sriov 'ip,dl_dst=e4:11:22:33:44:50,actions= meter:1,output:enp4s0f0_0' ovs-ofctl -O OpenFlow13 add-flow ovs-sriov 'ip,dl_src=e4:11:22:33:44:50,actions= output:enp4s0f0' ovs-ofctl -O OpenFlow13 add-flow ovs-sriov 'arp,actions=normal' 

  4. Run iperf server and be ready to receive UDP traffic. On the outer node, run iperf client to send UDP traffic to this VF. After traffic starts, check the offloaded meter rule.

    Copy
    Copied!
                

    ovs-appctl dpctl/dump-flows --names type=offloaded   recirc_id(0),in_port(enp4s0f0),eth(dst=e4:11:22:33:44:50),eth_type(0x0800),ipv4(frag=no), packets:11626587, bytes:17625889188, used:0.470s, actions:meter(0),enp4s0f0_0

In order to verify metering, iperf client should set the target bandwidth with a number which is larger than the meter rate configured. Then it will be visible that packets are received with the limited rate on the server side and the extra packets are dropped by hardware.

Multiport eSwitch Mode

The multiport eSwitch mode allows to add rules on a VF representor with an action forwarding the packet to the physical port of the physical function. This can be used to implement failover or forward packets based on external information such the cost of the route.

  1. To configure this more, the nvconig parameter LAG_RESOURCE_ALLOCATION must be set.

  2. After the driver loads, configure multiport eSwitch for each PF where enp8s0f0 and enp8s0f1 represent the netdevices for the PFs.

    Copy
    Copied!
                

    echo multiport_esw > /sys/class/net/enp8s0f0/compat/devlink/lag_port_select_mode echo multiport_esw > /sys/class/net/enp8s0f1/compat/devlink/lag_port_select_mode

    The mode becomes operational after entering switchdev mode on both PFs.

Rule example:

Copy
Copied!
            

tc filter add dev enp8s0f0_0 prot ip root flower dst_ip 7.7.7.7 action mirred egress redirect dev enp8s0f1

OVS-DPDK Hardware Offloads

OVS-DPDK Hardware Offloads Configuration

To configure OVS-DPDK HW offloads:

  1. Unbind the VFs.

    Copy
    Copied!
                

    echo 0000:04:00.2 > /sys/bus/pci/drivers/mlx5_core/unbind echo 0000:04:00.3 > /sys/bus/pci/drivers/mlx5_core/unbind

    Note: VMs with attached VFs must be powered off to be able to unbind the VFs.

  2. Change the e-switch mode from Legacy to SwitchDev on the PF device (make sure all VFs are unbound). This will also create the VF representor netdevices in the host OS.

    Copy
    Copied!
                

    echo switchdev > /sys/class/net/enp4s0f0/compat/devlink/mode

    To revert to SR-IOV Legacy mode:

    Copy
    Copied!
                

    echo legacy > /sys/class/net/enp4s0f0/compat/devlink/mode

    Note that running this command will also result in the removal of the VF representor netdevices.

  3. Bind the VFs.

    Copy
    Copied!
                

    echo 0000:04:00.2 > /sys/bus/pci/drivers/mlx5_core/bind echo 0000:04:00.3 > /sys/bus/pci/drivers/mlx5_core/bind

  4. Run the Open vSwitch service.

    Copy
    Copied!
                

    systemctl start openvswitch

  5. Enable hardware offload (disabled by default).

    Copy
    Copied!
                

    ovs-vsctl --no-wait set Open_vSwitch . other_config:dpdk-init=true ovs-vsctl set Open_vSwitch . other_config:hw-offload=true

  6. Configure the DPDK white list.

    Copy
    Copied!
                

    ovs-vsctl --no-wait set Open_vSwitch . other_config:dpdk-extra="-a 0000:01:00.0,representor=[0],dv_flow_en=1,dv_esw_en=1,dv_xmeta_en=1"

    Note

    Representor=[0-N]

  7. Restart the Open vSwitch service. This step is required for HW offload changes to take effect.

    Copy
    Copied!
                

    systemctl restart openvswitch

  8. Create OVS-DPDK bridge.

    Copy
    Copied!
                

    ovs-vsctl --no-wait add-br br0-ovs -- set bridge br0-ovs datapath_type=netdev

  9. Add PF to OVS.

    Copy
    Copied!
                

    ovs-vsctl add-port br0-ovs pf -- set Interface pf type=dpdk options:dpdk-devargs=0000:88:00.0

  10. Add representor to OVS.

    Copy
    Copied!
                

    ovs-vsctl add-port br0-ovs representor -- set Interface representor type=dpdk options:dpdk-devargs=0000:88:00.0,representor=[0]

    Note

    Representor=[0-N]

Offloading VXLAN Encapsulation/Decapsulation Actions

vSwitch in userspace rather than kernel-based Open vSwitch requires an additional bridge. The purpose of this bridge is to allow use of the kernel network stack for routing and ARP resolution.

The datapath needs to look-up the routing table and ARP table to prepare the tunnel header and transmit data to the output port.

Configuring VXLAN Encap/Decap Offloads

Note

The configuration is done with:

  • PF on 0000:03:00.0 PCI and MAC 98:03:9b:cc:21:e8

  • Local IP 56.56.67.1 - br-phy interface will be configured to this IP

  • Remote IP 56.56.68.1

To configure OVS-DPDK VXLAN:

  1. Create a br-phy bridge.

    Copy
    Copied!
                

    ovs-vsctl add-br br-phy -- set Bridge br-phy datapath_type=netdev -- br-set-external-id br-phy bridge-id br-phy -- set bridge br-phy fail-mode=standalone other_config:hwaddr=98:03:9b:cc:21:e8

  2. Attach PF interface to br-phy bridge.

    Copy
    Copied!
                

    ovs-vsctl add-port br-phy p0 -- set Interface p0 type=dpdk options:dpdk-devargs=0000:03:00.0

  3. Configure IP to the bridge.

    Copy
    Copied!
                

    ip addr add 56.56.67.1/24 dev br-phy

  4. Create a br-ovs bridge.

    Copy
    Copied!
                

    ovs-vsctl add-br br-ovs -- set Bridge br-ovs datapath_type=netdev -- br-set-external-id br-ovs bridge-id br-ovs -- set bridge br-ovs fail-mode=standalone

  5. Attach representor to br-ovs.

    Copy
    Copied!
                

    ovs-vsctl add-port br-ovs pf0vf0 -- set Interface pf0vf0 type=dpdk options:dpdk-devargs=0000:03:00.0,representor=[0]

  6. Add a port for the VXLAN tunnel.

    Copy
    Copied!
                

    ovs-vsctl add-port ovs-sriov vxlan0 -- set interface vxlan0 type=vxlan options:local_ip=56.56.67.1 options:remote_ip=56.56.68.1 options:key=45 options:dst_port=4789

Connection Tracking Offload

Connection tracking enables stateful packet processing by keeping a record of currently open connections.
OVS flows using connection tracking can be accelerated using advanced Network Interface Cards (NICs) by offloading established connections.

To view offloaded connections, run:

Copy
Copied!
            

ovs-appctl dpctl/offload-stats-show


SR-IOV VF LAG

To configure OVS-DPDK SR-IOV VF LAG:

  1. Enable SR-IOV on the NICs.

    Copy
    Copied!
                

    mlxconfig -d <PCI> set SRIOV_EN=1

  2. Allocate the desired number of VFs per port.

    Copy
    Copied!
                

    echo $n > /sys/class/net/<net name>/device/sriov_numvfs

  3. Unbind all VFs.

    Copy
    Copied!
                

    echo <VF PCI> >/sys/bus/pci/drivers/mlx5_core/unbind

  4. Change both NICs' mode to SwitchDev.

    Copy
    Copied!
                

    devlink dev eswitch set pci/<PCI> mode switchdev

  5. Create Linux bonding using kernel modules.

    Copy
    Copied!
                

    modprobe bonding mode=<desired mode>

    Note: Other bonding parameters can be added here. The supported Bond modes are: Active-Backup, XOR and LACP.

  6. Bring all PFs and VFs down.

    Copy
    Copied!
                

    ip link set <PF/VF> down

  7. Attach both PFs to the bond.

    Copy
    Copied!
                

    ip link set <PF> master bond0

  8. To work with VF-LAG with OVS-DPDK, add the bond master (PF) to the bridge.

    Copy
    Copied!
                

    ovs-vsctl add-port br-phy p0 -- set Interface p0 type=dpdk options:dpdk-devargs=0000:03:00.0 options:dpdk-lsc-interrupt=true

  9. Add representor $N of PF0 or PF1 to a bridge.

    Copy
    Copied!
                

    ovs-vsctl add-port br-phy rep$N -- set Interface rep$N type=dpdk options:dpdk-devargs=<PF0 PCI>,representor=pf0vf$N   OR   ovs-vsctl add-port br-phy rep$N -- set Interface rep$N type=dpdk options:dpdk-devargs=<PF0 PCI>,representor=pf1vf$N

VirtIO Acceleration through VF Relay (Software & Hardware vDPA)

Note

Hardware vDPA is supported on ConnectX-6 Dx, ConnectX-6 Lx & BlueField-2 cards and above only.

Note

Hardware vDPA is enabled by default. In case your hardware does not support vDPA, the driver will fall back to Software vDPA.

To check which vDPA mode is activated on your driver, run: ovs-ofctl -O OpenFlow14 dump-ports br0-ovs and look for hw-mode flag.

Note

This feature has not been accepted to the OVS-DPDK Upstream yet, making its API subject to change.

In user space, there are two main approaches for communicating with a guest (VM), either through SR-IOV, or through virtIO.

Phy ports (SR-IOV) allow working with port representor, which is attached to the OVS and a matching VF is given with pass-through to the guest. HW rules can process packets from up-link and direct them to the VF without going through SW (OVS). Therefore, using SR-IOV achieves the best performance.

However, SR-IOV architecture requires the guest to use a driver specific to the underlying HW. Specific HW driver has two main drawbacks:

  1. Breaks virtualization in some sense (guest is aware of the HW). It can also limit the type of images supported.

  2. Gives less natural support for live migration.

Using virtIO port solves both problems. However, it reduces performance and causes loss of some functionalities, such as, for some HW offloads, working directly with virtIO. To solve this conflict, a new netdev type- dpdkvdpa has been created. The new netdev is similar to the regular DPDK netdev, yet introduces several additional functionalities.

dpdkvdpa translates between phy port to virtIO port. It takes packets from the Rx queue and sends them to the suitable Tx queue, and allows transfer of packets from virtIO guest (VM) to a VF, and vice-versa, benefitting from both SR-IOV and virtIO.

To add vDPA port:

Copy
Copied!
            

ovs-vsctl add-port br0 vdpa0 -- set Interface vdpa0 type=dpdkvdpa \ options:vdpa-socket-path=<sock path> \ options:vdpa-accelerator-devargs=<vf pci id> \ options:dpdk-devargs=<pf pci id>,representor=[id] \ options: vdpa-max-queues =<num queues> \ options: vdpa-sw=<true/false>

Note: vdpa-max-queues is an optional field. When the user wants to configure 32 vDPA ports, the maximum queues number is limited to 8.

vDPA Configuration in OVS-DPDK Mode

Prior to configuring vDPA in OVS-DPDK mode, follow the steps below.

  1. Generate the VF.

    Copy
    Copied!
                

    echo 0 > /sys/class/net/enp175s0f0/device/sriov_numvfs echo 4 > /sys/class/net/enp175s0f0/device/sriov_numvfs

  2. Unbind each VF.

    Copy
    Copied!
                

    echo <pci> > /sys/bus/pci/drivers/mlx5_core/unbind

  3. Switch to SwitchDev mode.

    Copy
    Copied!
                

    echo switchdev >> /sys/class/net/enp175s0f0/compat/devlink/mode

  4. Bind each VF.

    Copy
    Copied!
                

    echo <pci> > /sys/bus/pci/drivers/mlx5_core/bind

  5. Initialize OVS with:

    Copy
    Copied!
                

    ovs-vsctl --no-wait set Open_vSwitch . other_config:dpdk-init=true ovs-vsctl --no-wait set Open_vSwitch . other_config:hw-offload=true

To configure vDPA in OVS-DPDK mode on ConnectX-5 cards and above:

  1. Open vSwitch configuration.

    Copy
    Copied!
                

    ovs-vsctl --no-wait set Open_vSwitch . other_config:dpdk-extra="-a 0000:01:00.0,representor=[0],dv_flow_en=1,dv_esw_en=1,dv_xmeta_en=1" /usr/share/openvswitch/scripts/ovs-ctl restart

  2. Create OVS-DPDK bridge.

    Copy
    Copied!
                

    ovs-vsctl add-br br0-ovs -- set bridge br0-ovs datapath_type=netdev ovs-vsctl add-port br0-ovs pf -- set Interface pf type=dpdk options:dpdk-devargs=0000:01:00.0

  3. Create vDPA port as part of the OVS-DPDK bridge.

    Copy
    Copied!
                

    ovs-vsctl add-port br0-ovs vdpa0 -- set Interface vdpa0 type=dpdkvdpa options:vdpa-socket-path=/var/run/virtio-forwarder/sock0 options:vdpa-accelerator-devargs=0000:01:00.2 options:dpdk-devargs=0000:01:00.0,representor=[0] options: vdpa-max-queues=8

To configure vDPA in OVS-DPDK mode on BlueField cards:

Set the bridge with the software or hardware vDPA port:

  • On the ARM side:

    Create the OVS-DPDK bridge.

    Copy
    Copied!
                

    ovs-vsctl add-br br0-ovs -- set bridge br0-ovs datapath_type=netdev ovs-vsctl add-port br0-ovs pf -- set Interface pf type=dpdk options:dpdk-devargs=0000:af:00.0 ovs-vsctl add-port br0-ovs rep-- set Interface rep type=dpdk options:dpdk-devargs=0000:af:00.0,representor=[0]

  • On the host side:

    Create the OVS-DPDK bridge.

    Copy
    Copied!
                

    ovs-vsctl add-br br1-ovs -- set bridge br1-ovs datapath_type=netdev protocols=OpenFlow14 ovs-vsctl add-port br0-ovs vdpa0 -- set Interface vdpa0 type=dpdkvdpa options:vdpa-socket-path=/var/run/virtio-forwarder/sock0 options:vdpa-accelerator-devargs=0000:af:00.2

    Note: To configure SW vDPA, add "options:vdpa-sw=true" to the end of the command.

Software vDPA Configuration in OVS-Kernel Mode

SW vDPA can also be used in configurations where the HW offload is done through TC and not DPDK.

  1. Open vSwitch configuration.

    Copy
    Copied!
                

    ovs-vsctl set Open_vSwitch . other_config:dpdk-extra="-a 0000:01:00.0,representor=[0],dv_flow_en=1,dv_esw_en=0,idv_xmeta_en=0,isolated_mode=1" /usr/share/openvswitch/scripts/ovs-ctl restart

  2. Create OVS-DPDK bridge.

    Copy
    Copied!
                

    ovs-vsctl add-br br0-ovs -- set bridge br0-ovs datapath_type=netdev

  3. Create vDPA port as part of the OVS-DPDK bridge.

    Copy
    Copied!
                

    ovs-vsctl add-port br0-ovs vdpa0 -- set Interface vdpa0 type=dpdkvdpa options:vdpa-socket-path=/var/run/virtio-forwarder/sock0 options:vdpa-accelerator-devargs=0000:01:00.2 options:dpdk-devargs=0000:01:00.0,representor=[0] options: vdpa-max-queues=8

  4. Create Kernel bridge.

    Copy
    Copied!
                

    ovs-vsctl add-br br-kernel

  5. Add representors to Kernel bridge.

    Copy
    Copied!
                

    ovs-vsctl add-port br-kernel enp1s0f0_0 ovs-vsctl add-port br-kernel enp1s0f0

Large MTU/Jumbo Frame Configuration

To configure MTU/jumbo frames:

  1. Verify that the Kernel version on the VM is 4.14 or above.

    Copy
    Copied!
                

    cat /etc/redhat-release

  2. Set the MTU on both physical interfaces in the host.

    Copy
    Copied!
                

    ifconfig ens4f0 mtu 9216

  3. Send a large size packet and verify that it is sent and received correctly.

    Copy
    Copied!
                

    tcpdump -i ens4f0 -nev icmp & ping 11.100.126.1 -s 9188 -M do -c 1

  4. Enable host_mtu in xml, and add the following values to xml.

    Copy
    Copied!
                

    host_mtu=9216,csum=on,guest_csum=on,host_tso4=on,host_tso6=on

    Example:

    Copy
    Copied!
                

    <qemu:commandline> <qemu:arg value='-chardev'/> <qemu:arg value='socket,id=charnet1,path=/tmp/sock0,server'/> <qemu:arg value='-netdev'/> <qemu:arg value='vhost-user,chardev=charnet1,queues=16,id=hostnet1'/> <qemu:arg value='-device'/> <qemu:arg value='virtio-net-pci,mq=on,vectors=34,netdev=hostnet1,id=net1,mac=00:21:21:24:02:01,bus=pci.0,addr=0xC,page-per-vq=on,rx_queue_size=1024,tx_queue_size=1024,host_mtu=9216,csum=on,guest_csum=on,host_tso4=on,host_tso6=on'/> </qemu:commandline>

  5. Add mtu_request=9216 option to the OvS ports inside the container and restart the OVS:

    Copy
    Copied!
                

    ovs-vsctl add-port br0-ovs pf -- set Interface pf type=dpdk options:dpdk-devargs=0000:c4:00.0 mtu_request=9216

    OR:

    Copy
    Copied!
                

    ovs-vsctl add-port br0-ovs vdpa0 -- set Interface vdpa0 type=dpdkvdpa options:vdpa-socket-path=/tmp/sock0 options:vdpa-accelerator-devargs=0000:c4:00.2 options:dpdk-devargs=0000:c4:00.0,representor=[0] mtu_request=9216 /usr/share/openvswitch/scripts/ovs-ctl restart

  6. Start the VM and configure the MTU on the VM.

    Copy
    Copied!
                

    ifconfig eth0 11.100.124.2/16 up ifconfig eth0 mtu 9216 ping 11.100.126.1 -s 9188 -M do -c1

E2E Cache

Note

This feature is at beta level.

OVS offload rules are based on a multi-table architecture. E2E cache feature enables merging the multi-table flow matches and actions into one joint flow.

This improves connection tracking performance by using a single-table when exact match is detected.

  • To set the E2E cache size (default = 4k):

    Copy
    Copied!
                

    ovs-vsctl set open_vswitch . other_config:e2e-size=<size> systemctl restart openvswitch

    Note: Make sure to restart the openvswitch service in order for the configuration to take effect.

  • To enable/disable E2E cache (default = disabled) :

    Copy
    Copied!
                

    ovs-vsctl set open_vswitch . other_config:e2e-enable=<true/false> systemctl restart openvswitch

    Note: Make sure to restart the openvswitch service in order for the configuration to take effect.

  • To run E2E cache statistics:

    Copy
    Copied!
                

    ovs-appctl dpctl/dump-e2e-stats

  • To run E2E cache flows:

    Copy
    Copied!
                

    ovs-appctl dpctl/dump-e2e-flows

Geneve Encapsulation/Decapsulation

Geneve tunneling offload feature support includes matching on extension header.

To configure OVS-DPDK Geneve encap/decap:

  1. Create a br-phy bridge.

    Copy
    Copied!
                

    ovs-vsctl --may-exist add-br br-phy -- set Bridge br-phy datapath_type=netdev -- br-set-external-id br-phy bridge-id br-phy -- set bridge br-phy fail-mode=standalone

  2. Attach PF interface to br-phy bridge.

    Copy
    Copied!
                

    ovs-vsctl add-port br-phy pf -- set Interface pf type=dpdk options:dpdk-devargs=<PF PCI>

  3. Configure IP to the bridge.

    Copy
    Copied!
                

    ifconfig br-phy <$local_ip_1> up

  4. Create a br-int bridge.

    Copy
    Copied!
                

    ovs-vsctl --may-exist add-br br-int -- set Bridge br-int datapath_type=netdev -- br-set-external-id br-int bridge-id br-int -- set bridge br-int fail-mode=standalone

  5. Attach representor to br-int.

    Copy
    Copied!
                

    ovs-vsctl add-port br-int rep$x -- set Interface rep$x type=dpdk options:dpdk-devargs=<PF PCI>,representor=[$x]

  6. Add a port for the GENEVE tunnel.

    Copy
    Copied!
                

    ovs-vsctl add-port br-int geneve0 -- set interface geneve0 type=geneve options:key=<VNI> options:remote_ip=<$remote_ip_1> options:local_ip=<$local_ip_1>

Parallel Offloads

OVS-DPDK supports parallel insertion and deletion of offloads (flow & CT). While multiple threads are supported, by default only one is used.

To configure multiple threads:

Copy
Copied!
            

ovs-vsctl set Open_vSwitch . other_config:n-offload-threads=3

Make sure to restart the openvswitch service in order for the configuration to take effect.

Copy
Copied!
            

systemctl restart openvswitch

Note

For more information, see the OvS user manual.

sFlow

This feature allows for monitoring traffic sent between two VMs on the same host using an sFlow collector.

To sample all traffic over the OVS bridge, run the following:

Copy
Copied!
            

# ovs-vsctl -- --id=@sflow create sflow agent=\"$SFLOW_AGENT\" \ target=\"$SFLOW_TARGET:$SFLOW_HEADER\" header=$SFLOW_HEADER \ sampling=$SFLOW_SAMPLING polling=10 \ -- set bridge sflow=@sflow

Parameter

Description

SFLOW_AGENT

Indicates that the sFlow agent should send traffic from SFLOW_AGENT’s IP address

SFLOW_TARGET

Remote IP address of the sFLOW collector

SFLOW_PORT

Remote IP destination port of the sFlow collector

SFLOW_HEADER

Size of packet header to sample (in bytes)

SFLOW_SAMPLING

Sample rate

To clear the sFLOW configuration, runt he following:

Copy
Copied!
            

# ovs-vsctl clear bridge br-vxlan mirrors

Note

Currently sFlow for OVS-DPDK is supported without CT.


CT CT NAT

To enable ct-ct-nat offloads in OvS-DPDK, execute the following command (deafult value is false):

Copy
Copied!
            

ovs-vsctl set open_vswitch . other_config:ct-action-on-nat-conns=true

If disabled, ct-ct-nat configurations will not be fully offloaded, improving connection offloading rate for
other cases (ct and ct-nat).

If enabled, ct-ct-nat configurations will be fully offloaded but ct and ct-nat offloading
will be slower to be created.

OpenFlow Meters (OpenFlow13+):

OpenFlow meters in OVS are implemented according to RFC 2697 (Single Rate Three Color Marker—srTCM).

  • The srTCM meters an IP packet stream and marks its packets either green, yellow, or red. The color is decided on a Committed Information Rate (CIR) and two associated burst sizes, Committed Burst Size (CBS), and Excess Burst Size (EBS).

  • A packet is marked green if it does not exceed the CBS, yellow if it exceeds the CBS but not the EBS, and red otherwise.

  • The volume of green packets should never be smaller than the CIR.

To configure a meter in OVS:

  1. Create a meter over a certain bridge:

    1. Copy
      Copied!
                  

      ovs-ofctl -O openflow13 add-meter $bridge meter=$id,$pktps/$kbps,band=type=drop,rate=$rate,[burst,burst_size=$burst_size]

    2. Parameters:

      Parameter

      Description

      bridge

      Name of the bridge on which the meter will be applied.

      id

      Unique meter ID (32 bits) which will be used as an identifier for the meter.

      pktps/kbps

      Indication if the meter should work according to packets-per-second or kilobits-per-second.

      rate

      Rate of pktps/kbps of allowed data transmission.

      burst

      If set, enables burst support for meter bands through the “burst_size” parameter.

      burst_size

      If burst is specified for the meter entry, configures the maximum burst allowed for the band in kilobits/packets, depending on whether kbps or pktps was specified. If unspecified, the switch is free to select some reasonable value depending on its configuration. Currently, if burst was not specified, the burst_size parameter is set as the “rate”.

  2. Add the meter to a certain OpenFlow rule. For example:

    Copy
    Copied!
                

    ovs-ofctl -O openflow13 add-flow $bridge "table=0,actions=meter:$id,normal“

  3. View the meter statistics:

    Copy
    Copied!
                

    ovs-ofctl -O openflow13 meter-stats $bridge meter=$id

  4. For more information, refer to openvswitch documentation http://www.openvswitch.org/support/dist-docs/ovs-ofctl.8.txt

Hardware vDPA Installation

Hardware vDPA requires QEMU v2.12 (or with upstream 6.1.0) and DPDK v20.11 as minimal versions.

To install QEMU:

  1. Clone the sources:

    Copy
    Copied!
                

    git clone https://git.qemu.org/git/qemu.git cd qemu git checkout v2.12

  2. Build QEMU:

    Copy
    Copied!
                

    mkdir bin cd bin ../configure --target-list=x86_64-softmmu --enable-kvm make -j24

To install DPDK:

  1. Clone the sources:

    Copy
    Copied!
                

    git clone git://dpdk.org/dpdk cd dpdk git checkout v20.11

  2. Install dependencies (if needed):

    Copy
    Copied!
                

    yum install cmake gcc libnl3-devel libudev-devel make pkgconfig valgrind-devel pandoc libibverbs libmlx5 libmnl-devel -y

  3. Configure DPDK:

    Copy
    Copied!
                

    export RTE_SDK=$PWD make config T=x86_64-native-linuxapp-gcc cd build sed -i 's/\(CONFIG_RTE_LIBRTE_MLX5_PMD=\)n/\1y/g' .config sed -i 's/\(CONFIG_RTE_LIBRTE_MLX5_VDPA_PMD=\)n/\1y/g' .config

  4. Build DPDK:

    Copy
    Copied!
                

    make -j

  5. Build the vDPA application:

    Copy
    Copied!
                

    cd $RTE_SDK/examples/vdpa/ make -j

Hardware vDPA Configuration

To configure huge pages:

Copy
Copied!
            

mkdir -p /hugepages mount -t hugetlbfs hugetlbfs /hugepages echo <more> > /sys/devices/system/node/node0/hugepages/hugepages-1048576kB/nr_hugepages echo <more> > /sys/devices/system/node/node1/hugepages/hugepages-1048576kB/nr_hugepages

To configure a vDPA VirtIO interface in an existing VM's xml file (using libvirt):

  1. Open the VM's configuration xml for editing:

    Copy
    Copied!
                

    virsh edit <domain name>

  2. Modify/add the following:

    1. Change the top line to:

      Copy
      Copied!
                  

      <domain type='kvm' xmlns:qemu='http://libvirt.org/schemas/domain/qemu/1.0'>

    2. Assign a memory amount and use 1GB page size for hugepages (size must be the same as used for the vDPA application), so that the memory configuration looks like the following.

      Copy
      Copied!
                  

      <memory unit='KiB'>4194304</memory> <currentMemory unit='KiB'>4194304</currentMemory> <memoryBacking> <hugepages> <page size='1048576' unit='KiB'/> </hugepages> </memoryBacking>

    3. Assign an amount of CPUs for the VM CPU configuration, so that the vcpu and cputune configuration looks like the following.

      Copy
      Copied!
                  

      <vcpu placement='static'>5</vcpu> <cputune> <vcpupin vcpu='0' cpuset='14'/> <vcpupin vcpu='1' cpuset='16'/> <vcpupin vcpu='2' cpuset='18'/> <vcpupin vcpu='3' cpuset='20'/> <vcpupin vcpu='4' cpuset='22'/> </cputune>

    4. Set the memory access for the CPUs to be shared, so that the cpu configuration looks like the following.

      Copy
      Copied!
                  

      <cpu mode='custom' match='exact' check='partial'> <model fallback='allow'>Skylake-Server-IBRS</model> <numa> <cell id='0' cpus='0-4' memory='8388608' unit='KiB' memAccess='shared'/> </numa> </cpu>

    5. Set the emulator in use to be the one built in step "2. Build QEMU" above, so that the emulator configuration looks as follows.

      Copy
      Copied!
                  

      <emulator><path to qemu executable></emulator>

    6. Add a virtio interface using qemu command line argument entries, so that the new interface snippet looks as follows.

      Copy
      Copied!
                  

      <qemu:commandline> <qemu:arg value='-chardev'/> <qemu:arg value='socket,id=charnet1,path=/tmp/sock-virtio0'/> <qemu:arg value='-netdev'/> <qemu:arg value='vhost-user,chardev=charnet1,queues=16,id=hostnet1'/> <qemu:arg value='-device'/> <qemu:arg value='virtio-net-pci,mq=on,vectors=6,netdev=hostnet1,id=net1,mac=e4:11:c6:d3:45:f2,bus=pci.0,addr=0x6, page-per-vq=on,rx_queue_size=1024,tx_queue_size=1024'/> </qemu:commandline>

      Note: In this snippet, the vhostuser socket file path, the amount of queues, the MAC and the PCI slot of the VirtIO device can be configured.

Running Hardware vDPA

Note

Hardware vDPA supports SwitchDev mode only.

Create the ASAP2 environment:

  1. Create the VFs.

  2. Enter switchdev mode.

  3. Set up OVS.

Run the vDPA application.

Copy
Copied!
            

cd $RTE_SDK/examples/vdpa/build ./vdpa -w <VF PCI BDF>,class=vdpa --log-level=pmd,info -- -i

Create a vDPA port via the vDPA application CLI.

Copy
Copied!
            

create /tmp/sock-virtio0 <PCI DEVICE BDF>

Note: The vhostuser socket file path must be the one used when configuring the VM.

Start the VM.

Copy
Copied!
            

virsh start <domain name>

For further information on the vDPA application, please visit: https://doc.dpdk.org/guides/sample_app_ug/vdpa.html.

Note
  • Bridge offload is supported on ConnectX-6 Dx NIC

  • Bridge offload is supported SwitchDev mode only

  • Bridge offload is supported from kernel version 5.15

A Linux bridge is in-kernel software network switch (based on and implements subset of IEEE 802.1D standard) that is used to connect Ethernet segments together in a protocol-independent way. Packets are forwarded based on L2 Ethernet header addresses.

mlx5 provides capabilities to offload bridge data-plane unicast packet forwarding and VLAN management to hardware.

Basic Configuration

  1. Initialize the ASAP2 environment:

    1. Create the VFs.

    2. Enter switchdev mode.

  2. Create a bridge and add mlx5 representors to bridge:

    Copy
    Copied!
                

    ip link add name bridge0 type bridge ip link set enp8s0f0_0 master bridge0

Configuring VLAN

  1. Enable VLAN filtering on the bridge.

    Copy
    Copied!
                

    ip link set bridge0 type bridge vlan_filtering 1

  2. Configure port VLAN matching (trunk mode). In this configuration, only packets with specified VID are allowed.

    Copy
    Copied!
                

    bridge vlan add dev enp8s0f0_0 vid 2

  3. Configure port VLAN tagging (access mode). In this configuration VLAN header in pushed/popped on reception/transmission on port.

    Copy
    Copied!
                

    bridge vlan add dev enp8s0f0_0 vid 2 pvid untagged

VF LAG Support

Bridge supports offloading on bond net device that is fully initialized with mlx5 uplink representors and is in single (shared) FDB LAG mode. Details about initialization of LAG are provided in SR-IOV VF LAG section, above.

Add bonding net device to bridge.

Copy
Copied!
            

ip link set bond0 master bridge0

For further information on interacting with Linux bridge via iproute2 bridge tool, please consult man page (man 8 bridge).

Download and install the MFT package corresponding to your computer’s operating system. You would need the kernel-devel or kernel-headers RPM before the tools are built and installed.
The package is available at nvidia.com/en-us/networking/ → Products → Software → Firmware Tools.

  1. Start the mst driver.

    Copy
    Copied!
                

    # mst start Starting MST (Mellanox Software Tools) driver set Loading MST PCI module - Success Loading MST PCI configuration module - Success Create devices

  2. Show the devices status.

    Copy
    Copied!
                

    ST modules: ------------ MST PCI module loaded MST PCI configuration module loaded   PCI devices: ------------ DEVICE_TYPE MST PCI RDMA NET NUMA ConnectX4lx(rev:0) /dev/mst/mt4117_pciconf0.1 04:00.1 net-enp4s0f1 NA ConnectX4lx(rev:0) /dev/mst/mt4117_pciconf0 04:00.0 net-enp4s0f0 NA     # mlxconfig -d /dev/mst/mt4117_pciconf0 q | head -16   Device #1: ----------   Device type: ConnectX4lx PCI device: /dev/mst/mt4117_pciconf0   Configurations: Current SRIOV_EN True(1) NUM_OF_VFS 8 PF_LOG_BAR_SIZE 5 VF_LOG_BAR_SIZE 5 NUM_PF_MSIX 63 NUM_VF_MSIX 11 LINK_TYPE_P1 ETH(2) LINK_TYPE_P2 ETH(2)

  3. Make sure your configuration is as follows:

    * SR-IOV is enabled (SRIOV_EN=1)
    * The number of enabled VFs is enough for your environment (NUM_OF_VFS=N)
    * The port’s link type is Ethernet (LINK_TYPE_P1/2=2) when applicable
    If this is not the case, use mlxconfig to enable that, as follows:

    1. Enable SR-IOV.

      Copy
      Copied!
                  

      # mlxconfig -d /dev/mst/mt4115_pciconf0 s SRIOV_EN=1

    2. Set the number of required VFs.

      Copy
      Copied!
                  

      # mlxconfig -d /dev/mst/mt4115_pciconf0 s NUM_OF_VFS=8 

    3. Set the link type to Ethernet.

      Copy
      Copied!
                  

      # mlxconfig -d /dev/mst/mt4115_pciconf0 s LINK_TYPE_P1=2 # mlxconfig -d /dev/mst/mt4115_pciconf0 s LINK_TYPE_P2=2

  4. Conduct a cold reboot (or a firmware reset).

    Copy
    Copied!
                

    # mlxfwreset -d /dev/mst/mt4115_pciconf0 reset

  5. Query the firmware to make sure everything is set correctly.

    Copy
    Copied!
                

    # mlxconfig -d /dev/mst/mt4115_pciconf0 q

© Copyright 2024, NVIDIA. Last updated on Jun 30, 2024.