MLNX-GW—Statistics and Alarms
stats alarm clear
stats alarm <alarm ID> clear Clears alarm state. | ||
Syntax Description | alarm ID | Alarms supported by the system, for example:
|
Default | N/A | |
Configuration Mode | config | |
History | 8.0.0100 | |
Example | gateway (config) # stats alarm cpu_util_indiv clear | |
Related Commands | show stats alarm | |
Notes |
stats alarm enable
stats alarm <alarm-id> enable Enables the alarm. | ||
Syntax Description | alarm ID | Alarms supported by the system, for example:
|
Default | The default is different per alarm-id | |
Configuration Mode | config | |
History | 8.0.0100 | |
Example | gateway (config) # stats alarm cpu_util_indiv enable | |
Related Commands | show stats alarm | |
Notes |
stats alarm event-repeat
stats alarm <alarm ID> event-repeat {single | while-not-cleared} Configures repetition of events from this alarm. | ||
Syntax Description | alarm ID | Alarms supported by the system, for example:
|
single | Does not repeat events: only sends one event whenever the alarm changes state. | |
while-not-cleared | Repeats error events until the alarm clears. | |
Default | single | |
Configuration Mode | config | |
History | 8.0.0100 | |
Example | gateway (config) # stats alarm cpu_util_indiv event-repeat single | |
Related Commands | show stats alarm | |
Notes |
stats alarm {rising | falling}
stats alarm <alarm ID> {rising | falling} {clear-threshold | error-threshold} <threshold-value> Configure alarms thresholds. | ||
Syntax Description | alarm ID | Alarms supported by the system, for example:
|
falling | Configures alarm for when the statistic falls too low. | |
rising | Configures alarm for when the statistic rises too high. | |
error-threshold | Sets threshold to trigger falling or rising alarm. | |
clear-threshold | Sets threshold to clear falling or rising alarm. | |
threshold-value | The desired threshold value, different per alarm. | |
Default | Default is different per alarm-id | |
Configuration Mode | config | |
History | 8.0.0100 | |
Example | gateway (config) # stats alarm cpu_util_indiv falling clear-threshold 10 | |
Related Commands | show stats alarm | |
Notes | Not all alarms support all four thresholds. |
stats alarm rate-limit
stats alarm <alarm ID> rate-limit {count <count-type> <count> | reset | window <window-type> <duration>} Configures alarms rate limit. | ||
Syntax Description | alarm ID | Alarms supported by the system, for example:
|
count-type | Long medium, or short count (number of alarms). | |
reset | Set the count and window durations to default values for this alarm. | |
window-type | Long medium, or short count, in seconds. | |
Default | Short window: 5 alarms in 1 hour | |
Configuration Mode | config | |
History | 8.0.0100 | |
Example | gateway (config) # stats alarm paging rate-limit window long 2000 | |
Related Commands | show stats alarm | |
Notes |
stats chd clear
stats chd <CHD ID> clear Clears CHD counters. | ||
Syntax Description | CHD ID | CHD supported by the system, for example:
|
Default | N/A | |
Configuration Mode | config | |
History | 8.0.0100 | |
Example | gateway (config) # stats chd memory_day clear | |
Related Commands | show stats chd | |
Notes |
stats chd enable
stats chd <chd-id> enable Enables the CHD. | ||
Syntax Description | chd-id | CHD supported by the system, for example:
|
Default | Enabled | |
Configuration Mode | config | |
History | 8.0.0100 | |
Example | gateway (config) # stats chd memory_day enable | |
Related Commands | show stats chd | |
Notes |
stats chd compute time
stats chd <CHD ID> compute time {interval | range} <number of seconds> Sets parameters for when this CHD is computed. | ||
Syntax Description | CHD ID | Possible IDs:
|
interval | Specifies calculation interval (how often to do a new calculation) in number of seconds | |
range | Specifies calculation range, in number of seconds | |
number of seconds | Number of seconds | |
Default | Different per CHD | |
Configuration Mode | config | |
History | 8.0.0100 | |
Example | gateway (config) # stats chd memory_day compute time interval 120 | |
Related Commands | show stats chd | |
Notes |
stats export
stats export <format> <sample-id> Exports collected information to a file. Can export extended "interface-ethernet", "interface-port-channel", "interface-mlag-port-channel"& "power" samples. | ||
Syntax Description | sample-id | Sample name for which report file should be generated.
|
format | Format of report file | |
Default | N/A | |
Configuration Mode | config | |
History | 8.0.0100 | |
Example | gateway (config) # stats export csv memory | |
Related Commands | show stats sample | |
Notes |
stats sample clear
stats sample <sample ID> clear Clears sample history. | ||
Syntax Description | sample ID | Possible sample IDs are:
|
Default | N/A | |
Configuration Mode | config | |
History | 8.0.0100 | |
Example | gateway (config) # stats sample temperature clear | |
Related Commands | show stats sample | |
Notes |
stats sample enable
stats sample <sample-id> enable Enables the sample. | ||
Syntax Description | sample-id | Possible sample IDs are:
|
Default | Enabled | |
Configuration Mode | config | |
History | 8.0.0100 | |
Example | gateway (config) # stats sample temperature enable | |
Related Commands | show stats sample | |
Notes |
stats sample interval
stats sample <sample-id> interval [<interval>] Sets the sampling interval between taking of sample records. | ||
Syntax Description | sample-id | Sample name for which report file should be generated.
|
interval | Measured in seconds. Range: 1 - 86400 (24 hours) | |
Default | Default for “interface” samples is 60 seconds | |
Configuration Mode | config | |
History | 8.0.0100 | |
Example | gateway (config) # stats sample interface-ethernet interval 1 | |
Related Commands | show stats sample | |
Notes |
stats sample max-entries
stats sample <sample-id> max-entries [<max-entries>] Sets number of records to be kept in memory for the counter. | ||
Syntax Description | sample-id | Sample name for which report file should be generated.
|
max-entries | Number of records | |
Default | Default “interface” samples is 100 records | |
Configuration Mode | config | |
History | 8.0.0100 | |
Example | gateway (config) # stats sample interface-ethernet max-entries 1000 | |
Related Commands | show stats sample | |
Notes |
|
stats clear-all
stats clear-all Clears data for all samples, CHDs, and status for all alarms. | ||
Syntax Description | N/A | |
Default | N/A | |
Configuration Mode | config | |
History | 8.0.0100 | |
Example | gateway (config) # stats clear-all | |
Related Commands | show stats sample | |
Notes |
show stats alarm
show stats alarm [<alarm-id> [rate-limit]] Displays status of all alarms or the specified alarm. | ||
Syntax Description | alarm-id | Available values:
|
rate-limit | Displays rate limit parameters | |
Default | N/A | |
Configuration Mode | Any command mode | |
History | 8.0.0100 | |
Example | gateway (config) # show stats alarm | |
Related Commands | stats alarm | |
Notes |
show stats chd
show stats chd [<chd-id>] Displays configuration of all statistics CHDs. | ||
Syntax Description | chd-id | Available values:
|
Default | N/A | |
Configuration Mode | Any command mode | |
History | 8.0.0100 | |
Example |
| |
Related Commands | stats chd | |
Notes |
show stats cpu
show stats cpu Displays some basic stats about CPU utilization:
| ||
Syntax Description | N/A | |
Default | N/A | |
Configuration Mode | Any command mode | |
History | 8.0.0100 | |
Example |
| |
Related Commands | ||
Notes |
show stats sample
show stats sample [<sample-id>] Displays sampling interval for all samples, or the specified one. | ||
Syntax Description | sample-id | Sample name for which report file should be generated.
|
Default | N/A | |
Configuration Mode | Any command mode | |
History | 8.0.0100 | |
Example | gateway (config) # show stats sample fan | |
Related Commands | ||
Notes |
show stats sample data
show stats sample <sample-id> data [interface {ethernet | port-channel | mlag-port-channel} <device/port> [counter <counter-name>] ] [group name <group-name> [counter <counter-name>] ] [max-samples {<max-samples> | all}] Displays history of counter values (i.e. collected information for a sample). | ||
Syntax Description | sample-id | Sample name for which report file should be generated.
|
interface | Allows limiting output to a particular interface’s counters | |
group | Allows limiting output to a particular group of counters | |
counter | Allows limiting output to a particular counter. This option is available only if the option interface or group is chosen. | |
max-samples | Allows choosing a number of counter records to display. Range: 1-1000 records. The “all” option is meant for all available records. By default, 20 counter records are displayed. | |
Default | N/A | |
Configuration Mode | Any command mode | |
History | 8.0.0100 | |
Example | ||
gateway (config) # show stats sample interface-ethernet data interface ethernet 1/1 max-samples 1 Sampling data for Interface ethernet counters: | ||
Related Commands | ||
Notes |
|