Flow Control

Priority Flow Control (PFC) IEEE 802.1Qbb applies pause functionality to specific classes of traffic on the Ethernet link. For example, PFC can provide lossless service for the RoCE traffic and best-effort service for the standard Ethernet traffic. PFC can provide different levels of service to specific classes of Ethernet traffic (using IEEE 802.1p traffic classes).

Configuring PFC on ConnectX-4 and above

  1. Enable PFC on the desired priority:

    Copy
    Copied!
                

    mlnx_qos -i <ethX> --pfc <0/1>,<0/1>,<0/1>,<0/1>,<0/1>,<0/1>,<0/1>,<0/1>

    Example (Priority=4):

    Copy
    Copied!
                

    mlnx_qos -i eth1 --pfc 0,0,0,0,1,0,0,0

  2. Create a VLAN interface:

    Copy
    Copied!
                

    vconfig add <ethX> <VLAN_ID>

    Example (VLAN_ID=5):

    Copy
    Copied!
                

    vconfig add eth1 5

  3. Set egress mapping:

    1. For Ethernet traffic:

      Copy
      Copied!
                  

      vconfig set_egress_map <vlan_einterface> <skprio> <up>

      Example (skprio=3, up=5):

      Copy
      Copied!
                  

      vconfig set_egress_map eth1.5 3 5

  4. Create 8 Traffic Classes (TCs):

    Copy
    Copied!
                

    tc_wrap.py -i <interface>

  5. Enable PFC on the switch.
    For information on how to enable PFC on your respective switch, please refer to Switch FC/PFC Configuration sections in the RDMA/RoCE Solutions Community page .

PFC Configuration Using LLDP DCBX

PFC Configuration on Hosts

PFC Auto-Configuration Using LLDP Tool in the OS

  1. Start lldpad daemon on host.

    Copy
    Copied!
                

    lldpad -d Or service lldpad start

  2. Send lldpad packets to the switch.

    Copy
    Copied!
                

    lldptool set-lldp -i <ethX> adminStatus=rxtx ; lldptool -T -i <ethX> -V sysName enableTx=yes; lldptool -T -i <ethX> -V portDesc enableTx=yes ; lldptool -T -i <ethX> -V sysDesc enableTx=yes lldptool -T -i <ethX> -V sysCap enableTx=yess lldptool -T -i <ethX> -V mngAddr enableTx=yess lldptool -T -i <ethX> -V PFC enableTx=yes; lldptool -T -I <ethX> -V CEE-DCBX enableTx=yes;

  3. Set the PFC parameters.

  • For the CEE protocol, use dcbtool:

    Copy
    Copied!
                

    dcbtool sc <ethX> pfc pfcup:<xxxxxxxx>

    Example:

    Copy
    Copied!
                

    dcbtool sc eth6 pfc pfcup:01110001

    where:

    [pfcup:xxxxxxxx]

    Enables/disables priority flow control. From left to right (priorities 0-7) - x can be equal to either 0 or 1. 1 indicates that the priority is configured to transmit priority pause.

  • For IEEE protocol, use lldptool:

    Copy
    Copied!
                

    lldptool -T -i <ethX> -V PFC enabled=x,x,x,x,x,x,x,x 

    Example:

    Copy
    Copied!
                

    lldptool -T -i eth2 -V PFC enabled=1,2,4 

    where:

    enabled

    Displays or sets the priorities with PFC enabled. The set attribute takes a comma-separated list of priorities to enable, or the string none to disable all priorities.

PFC Auto-Configuration Using LLDP in the Firmware (for mlx5 driver)

There are two ways to configure PFC and ETS on the server:

  1. Local Configuration - Configuring each server manually.

  2. Remote Configuration - Configuring PFC and ETS on the switch, after which the switch will pass the configuration to the server using LLDP DCBX TLVs.

    There are two ways to implement the remote configuration using mlx5 driver:

    1. Configuring the adapter firmware to enable DCBX.

    2. Configuring the host to enable DCBX.

For further information on how to auto-configure PFC using LLDP in the firmware, refer to the HowTo Auto-Config PFC and ETS on ConnectX-4 via LLDP DCBX Community post.

PFC Configuration on Switches

  1. In order to enable DCBX, LLDP should first be enabled:

    Copy
    Copied!
                

    switch (config) # lldp show lldp interfaces ethernet remote

  2. Add DCBX to the list of supported TLVs per required interface.

    For IEEE DCBX:

    Copy
    Copied!
                

    switch (config) # interface 1/1 switch (config interface ethernet 1/1) # lldp tlv-select dcbx

    For CEE DCBX:

    Copy
    Copied!
                

    switch (config) # interface 1/1 switch (config interface ethernet 1/1) # lldp tlv-select dcbx-cee

  3. [Optional] Application Priority can be configured on the switch, with the required ethertype and priority. For example, IP packet, priority 1:

    Copy
    Copied!
                

    switch (config) # dcb application-priority 0x8100 1

  4. Make sure PFC is enabled on the host (for enabling PFC on the host, refer to PFC Configuration on Hosts section above). Once it is enabled, it will be passed in the LLDP TLVs.

  5. Enable PFC with the desired priority on the Ethernet port.

    Copy
    Copied!
                

    dcb priority-flow-control enable force dcb priority-flow-control priority <priority> enable interface ethernet <port> dcb priority-flow-control mode on force

    Example - Enabling PFC with priority 3 on port 1/1:

    Copy
    Copied!
                

    dcb priority-flow-control enable force dcb priority-flow-control priority 3 enable interface ethernet 1/1 dcb priority-flow-control mode on force

Priority Counters

Several ingress and egress counters per priority are supported. Run ethtool -S to get the full list of port counters.

ConnectX-4 Counters

  • Rx and Tx Counters:

    • Packets

    • Bytes

    • Octets

    • Frames

    • Pause

    • Pause frames

    • Pause Duration

    • Pause Transition

ConnectX-4 Example

Copy
Copied!
            

# ethtool -S eth35 | grep prio4 prio4_rx_octets: 62147780800 prio4_rx_frames: 14885696 prio4_tx_octets: 0 prio4_tx_frames: 0 prio4_rx_pause: 0 prio4_rx_pause_duration: 0 prio4_tx_pause: 26832 prio4_tx_pause_duration: 14508 prio4_rx_pause_transition: 0

Note: The Pause counters in ConnectX-4 are visible via ethtool only for priorities on which PFC is enabled.

PFC Storm Prevention

PFC storm prevention enables toggling between default and auto modes.
The stall prevention timeout is configured to 8 seconds by default. Auto mode sets the stall prevention timeout to be 100 msec.
The feature can be controlled using sysfs in the following directory: /sys/class/net/eth*/settings/ pfc_stall_prevention

  • To query the PFC stall prevention mode:

    Copy
    Copied!
                

    cat /sys/class/net/eth*/settings/pfc_stall_prevention

    Example

    Copy
    Copied!
                

    $ cat /sys/class/net/ens6/settings/pfc_stall_prevention default

  • To configure the PFC stall prevention mode:

    Copy
    Copied!
                

    Echo "auto"/"default" > /sys/class/net/eth*/settings/pfc_stall_prevention

The following two counters were added to the ethtool -S:

  • tx_Pause_storm_warning_events - when the device is stalled for a period longer than a pre-configured watermark, the counter increases, allowing the debug utility an insight into current device status.

  • tx_pause_storm_error_events - when the device is stalled for a period longer than a pre-configured timeout, the pause transmission is disabled, and the counter increase.

Dropless RQ feature enables the driver to notify the FW when SW receive queues are overloaded. This scenario takes place when the handling of SW receive queue is slower than the handling of the HW receive queues.
When this feature is enabled, a packet that is received while the receive queue is full will not be immediately dropped. The FW will accumulate these packets assuming posting of new WQEs will resume shortly. If received WQEs are not posted after a certain period of time, out_of_buffer counter will increase, indicating that the packet has been dropped.
This feature is disabled by default. In order to activate it, ensure that Flow Control feature is also enabled.

Copy
Copied!
            

ethtool --set-priv-flags ens6 dropless_rq on

To get the feature state, run:

Copy
Copied!
            

ethtool --show-priv-flags DEVNAME

Output example:

Copy
Copied!
            

Private flags for DEVNAME: rx_cqe_moder : on rx_cqe_compress: off sniffer : off dropless_rq : off hw_lro : off

To disable the feature, run:

Copy
Copied!
            

ethtool --set-priv-flags ens6 dropless_rq off