Bug Fixes in this Firmware Version
For a list of bug fixed from previous versions, see Bug Fixes History.
Internal Ref. |
Issues |
4129741 |
Description: In rare cases, when a SHARP job is stopped while ANDR operations were in use, the next job may fail and require switch reboot. |
Keywords: SHARP |
|
Discovered in Version: 31.2014.1000 |
|
Fixed in Version: 31.2014.2084 |
|
4146212 |
Description: Inaccurate credits configurations in switch data path which, in rare cases, can lead to unexpected behavior or performance degradation. |
Keywords: Credits, Data Path, Fatal Cause |
|
Discovered in Version: 31.2012.2014 |
|
Fixed in Version: 31.2014.2084 |
|
4037679 |
Description: In some cases where incorrect MAD handling causes the switch to become unresponsive to the SM, a switch reset is required. |
Keywords: MADs |
|
Discovered in Version: 31.2014.1000 |
|
Fixed in Version: 31.2014.2084 |
|
3782281 3778631 |
Description: When performing a partial split (where only one port in a cage is split) on an optical module, port may not link up. |
Keywords: Optical Module, Split |
|
Discovered in Version: 31.2012.4006 |
|
Fixed in Version: 31.2014.2084 |
|
3605188 |
Description: Occasionally, when using an FR4-coherent optical module while running a split-unsplit flow, the port may not raise a link. |
Keywords: FR4-Coherent Optical Module |
|
Discovered in Version: 31.2012.1024 |
|
Fixed in Version: 31.2014.2084 |
|
3967793 |
Description: When cable is unplugged in unmanaged switches, port width remains 2X, even when using a 4X cable. |
Keywords: Cables Width |
|
Discovered in Version: 31.2012.1024 |
|
Fixed in Version: 31.2014.2084 |
|
4035403 |
Description: In cases of repeating flapping links, the pFRN recovery mechanism might not be triggered. |
Keywords: SHIELDv2, pFRN |
|
Discovered in Version: 31.2012.2234 |
|
Fixed in Version: 31.2014.2084 |