Internal Ref. |
Issues |
2063786 |
Description: Running 2 flows in parallel is currently not functional in SHARP (SAT). |
Keywords: SHARP (SAT), 2 flows |
|
Discovered in Version: 27.2000.3276 |
|
Fixed in Release: 27.2007.0618 |
|
1972573 |
Description: Reading the Serial Number by the MSPS register is not functional on the new Delta PSU model. |
Keywords: Delta PSU model, MSPS register |
|
Discovered in Version: 27.2000.2708 |
|
Fixed in Release: 27.2007.0618 |
|
1970878 |
Description: When using Mellanox AOC cables longer than 50m use one VL to achieve full wire speed. |
Keywords: Cables |
|
Fixed in Release: 27.2007.0618 |
|
2022524 |
Description: As the switch does not send auto-negotiation indication, after resetting/power cycling a ConnectX-6 HCA, some HCAs get stuck in "polling" state. |
Keywords: Auto-negotiation, HCA, switch |
|
Discovered in Version: 27.2000.2708 |
|
Fixed in Release: 27.2007.0300 |
|
1996051 |
Description: After performing a software reset on the switch while using an Active Copper Cable or Optics Cable, the link gets high BER and is not available for traffic forwarding. |
Keywords: Cables, BER |
|
Discovered in Version: 27.2000.2708 |
|
Fixed in Release: 27.2007.0300 |
|
2036930 |
Description: Degradation in throughput might be experienced when using HDR100 cables with a length of 30m and above. |
Keywords: Cables, Bandwidth |
|
Discovered in Version: 27.2000.2708 |
|
Fixed in Release: 27.2000.3276 |
|
1946287 |
Description: Fixed an issue that resulted in SHARP jobs getting stuck after stopping a job during SAT operation. |
Keywords: SHARP |
|
Discovered in Version: 27.2000.2306 |
|
Fixed in Release: 27.2000.2626 |
|
1778566 |
Description: Fixed an issue that caused the Rx buffers allocation after running OpenSM to be based on the default VLCap configuration instead of the Operational Vl configuration. |
Keywords: Rx buffers allocation, OpenSM |
|
Discovered in Version: 27.2000.2306 |
|
Fixed in Release: 27.2000.2626 |
|
1930686 |
Description: Fixed an issue that caused a multicast packet to be forwarded to a wrong port when the switch was configured to use the Split mode. |
Keywords: Switch multicast forwarding |
|
Discovered in Version: 27.2000.2182 |
|
Fixed in Release: 27.2000.2626 |
|
1761271 |
Description: CWDM4 AOM cable is currently not supported on Quantum switch systems. |
Keywords: Modules/Cables |
|
Discovered in Version: 27.2000.1400 |
|
Fixed in Release: 27.2000.2626 |
|
1713747 |
Description: When using splitter HDR optical cables, toggling the upper port causes the lower port to be toggled as well. |
Keywords: Cables, port toggling |
|
Discovered in Version: 27.2000.2046 |
|
Fixed in Release: 27.2000.2626 |
|
1834740 |
Description: Fixed an issue that resulted in high BER when using optical module with module firmware older than 37.50.316. |
Keywords: Optical cables, BER, cables firmware |
|
Discovered in Version: 27.2000.2182 |
|
Fixed in Release: 27.2000.2306 |
|
1899441 |
Description: Fixed an issue that caused the packets to be transmitted from a wrong output port due to a wrong configuration of the packet classification decision in the switch forwarding database cache key, that caused both AR eligible packets and AR ineligible packets to hit the same cache entry. |
Keywords: Switch forwarding, Adaptive Routing |
|
Discovered in Version: 27.2000.2046 |
|
Fixed in Release: 27.2000.2182 |
|
1885460 |
Description: On rare occasions, and under high SHARP load, switch SHARP operation might get stuck. |
Keywords: SHARP |
|
Discovered in Version: 27.2000.2046 |
|
Fixed in Release: 27.2000.2182 |
|
1859715 |
Description: The bandwidth on MFS1S00-H050E cables is 99G/s and on MFS1S00-H100E cables is 67Gb/s when connecting at HDR speed to an HDR switch. |
Keywords: Cables |
|
Discovered in Version: 27.2000.1886 |
|
Fixed in Release: 27.2000.2046 |
|
1797452 |
Description: A port may hang while Link-Maintenance runs on it and the second port’s link is toggled. |
Keywords: Link-Maintenance, port toggling |
|
Discovered in Version: 27.2000.1600 |
|
Fixed in Release: 27.2000.1886 |
|
1698990 |
Description: HDR link up time when using optical cables may take 6 minutes or more (up to 20 minutes). |
Keywords: HDR, optical cables, link up times |
|
Discovered in Version: 27.2000.1100 |
|
Fixed in Release: 27.2000.1886 |
|
1718734/ 1723236/ 1718645/ 1710631 |
Description: On rare occasions, HDR link may not raise properly when using optical cables. |
Keywords: HDR link |
|
Discovered in Version: 27.2000.1012 |
|
Fixed in Release: 27.2000.1600 |
|
1774870 |
Description: Link flapping and packet loss during High/Low temperature changes. |
Keywords: Link |
|
Discovered in Version: 27.2000.1400 |
|
Fixed in Release: 27.2000.1600 |
|
1778837 |
Description: When using a copper splitter cable up to 2m length in HDR100 mode, traffic may drop. |
Keywords: Cable, HDR100 |
|
Discovered in Version: 27.2000.1400 |
|
Fixed in Release: 27.2000.1600 |
|
1534459 |
Description: When working with 8 VLs, TP does not function due to buffers’ configuration. |
Keywords: VLs, latency, performance |
|
Discovered in Version: 27.2000.1100 |
|
Fixed in Release: 27.2000.1400 |
|
1605587 |
Description: Fixed an issue that cause the green port LED to blink in the same frequency regardless of the link speed rate set. |
Keywords: Port LED |
|
Discovered in Version: 27.1910.0618 |
|
Fixed in Release: 27.2000.1142 |
|
1598550 |
Description: Fixed an issue that prevented the port from being split when the request (command) was sent from the NV config tool. |
Keywords: Split Port |
|
Discovered in Version: 27.1910.0618 |
|
Fixed in Release: 27.1910.0620 |