Bug Fixes History
Internal Ref. |
Issue |
2249227 |
Description: The SN and PN fields values in Switch-IB 2 with 550W PSU show as zero in some devices. |
Keywords: 550W PSU |
|
Discovered in Release: 15.2008.1300 |
|
Fixed in Release: 15.2008.1600 |
|
1786686 |
Description: Wrong behavior of ARGroupTableCopy MAD. |
Keywords: Adaptive Routing |
|
Discovered in Release: 15.2000.1142 |
|
Fixed in Release: 15.2000.1600 |
|
1730194 |
Description: In rare cases, when connecting between Switch-IB/Switch-IB 2 and Quantum switch systems, traffic loss might occur. |
Keywords: Traffic, Switch-IB/Switch-IB 2, Quantum |
|
Discovered in Release: 15.2000.1000 |
|
Fixed in Release: 15.2000.1142 |
|
1337469 |
Description: In rare cases, when a receiver’s electrical eye is narrow, link might raise with BER higher (worse) than 10-12. |
Keywords: Link |
|
Discovered in Release: 15.1500.0034 |
|
Fixed in Release: 15.1630.0206 |
|
1092005 |
Description: Enable SDR speed regardless of cable supported speeds |
Keywords: Link |
|
Discovered in Release: 15.1400.0102 |
|
Fixed in Release: 15.1500.0106 |
|
1089528 |
Description: SHARP not functional in case of groups larger than 14 members |
Keywords: SHARP |
|
Discovered in Release: 15.1430.0160 |
|
Fixed in Release: 15.1500.0106 |
|
964972 |
Description: In info block 29 (Thermal algorithm values): DELTA TEMP REPORTING > '4' will be considered '1'. DELTA TEMP REPORTING = 1,2,3 returns no issues. |
Keywords: Thermal Management |
|
Discovered in Release: 15.1310.0138 |
|
Fixed in Release: 15.1310.0150 |
|
- |
Description: VL arbitration does not distribute traffic as expected in case of multiple VLs |
Keywords: General |
|
Discovered in Release: 15.1200.0102 |
|
Fixed in Release: 15.1300.0100 |