Threshold-Crossing Events Reference
This reference lists the threshold-based events that UFM supports, each including a set of attributes listed below. You can view these messages through TBD. For details about configuring notifications for these events, refer to TBD.
Event ID: Unique event identifier
Event Name: Short description of the event
To log: A flag which defines whether the event will be sent to UFM events log or not (1 or 0, respectively).
Alarm: A flag which defines whether UFM alarm is generated when the specified event is triggered by UFM (1 means an alarm is generated). Alarms are used to allow a notification with significant indication.
Default Severity: Indicates the alarm severity (Info, Warning, Minor, Critical)
Default Threshold: Event dependent threshold (for example, event occurrence, counter threshold or temperature threshold).
Default TTL: TTL (Alarm Time to Live) sets the time during which the alarm on the event is visible on UFM Web UI. TTL is defined in seconds. CAUTION: Setting the TTL to 0 makes the alarm permanent, meaning that the alarm does not disappear from the Web UI until cleared manually.
Related Object: The object (context) to which the UFM event is related to (port, switch, gateway, grid, etc).
Category: Indicates the category to which the event is related to.
Source: Indicates the origin source of the specified event (SM, Telemetry, Licensing, UFM)
For information about defining event policy, see Configuring Event Management.
Event ID |
Event Name |
To Log |
Alarm |
Default Severity |
Default Threshold |
Default TTL |
Related Object |
Category |
Source |
64 |
GID Address In Service |
1 |
0 |
Info |
1 |
300 |
Port |
Fabric Notification |
SM |
65 |
GID Address Out of Service |
1 |
0 |
Warning |
1 |
300 |
Port |
Fabric Notification |
SM |
66 |
New MCast Group Created |
1 |
0 |
Info |
1 |
300 |
Port |
Fabric Notification |
SM |
67 |
MCast Group Deleted |
1 |
0 |
Info |
1 |
300 |
Port |
Fabric Notification |
SM |
110 |
Symbol Error |
1 |
1 |
Warning |
200 |
300 |
Port |
Hardware |
Telemetry |
111 |
Link Error Recovery |
1 |
1 |
Minor |
1 |
300 |
Port |
Hardware |
Telemetry |
112 |
Link Downed |
1 |
1 |
Critical |
1 |
300 |
Port |
Hardware |
Telemetry |
113 |
Port Receive Errors |
1 |
1 |
Minor |
5 |
300 |
Port |
Hardware |
Telemetry |
114 |
Port Receive Remote Physical Errors |
0 |
0 |
Minor |
5 |
300 |
Port |
Hardware |
Telemetry |
115 |
Port Receive Switch Relay Errors |
1 |
1 |
Minor |
999 |
300 |
Port |
Fabric Configuration |
Telemetry |
116 |
Port Xmit Discards |
1 |
1 |
Minor |
200 |
300 |
Port |
Communication Error |
Telemetry |
117 |
Port Xmit Constraint Errors |
1 |
1 |
Minor |
200 |
300 |
Port |
Communication Error |
Telemetry |
118 |
Port Receive Constraint Errors |
1 |
1 |
Minor |
200 |
300 |
Port |
Communication Error |
Telemetry |
119 |
Local Link Integrity Errors |
1 |
1 |
Minor |
5 |
300 |
Port |
Hardware |
Telemetry |
120 |
Excessive Buffer Overrun Errors |
1 |
1 |
Minor |
100 |
300 |
Port |
Communication Error |
Telemetry |
121 |
VL15 Dropped |
1 |
1 |
Minor |
50 |
300 |
Port |
Communication Error |
Telemetry |
122 |
Congested Bandwidth (%) Threshold Reached |
1 |
1 |
Minor |
10 |
300 |
Port |
Hardware |
Telemetry |
123 |
Port Bandwidth (%) Threshold Reached |
1 |
1 |
Minor |
95 |
300 |
Port |
Communication Error |
Telemetry |
130 |
Non-optimal link width |
1 |
1 |
Minor |
1 |
0 |
Port |
Hardware |
SM |
134 |
T4 Port Congested Bandwidth |
1 |
1 |
Warning |
10 |
300 |
Port |
Communication Error |
Telemetry |
141 |
Flow Control Update Watchdog Timer Expired |
1 |
0 |
Warning |
1 |
300 |
Port |
Hardware |
SM |
144 |
Capability Mask Modified |
1 |
0 |
Info |
1 |
300 |
Port |
Fabric Notification |
SM |
145 |
System Image GUID changed |
1 |
0 |
Info |
1 |
300 |
Port |
Communication Error |
SM |
156 |
Link Speed Enforcement Disabled |
1 |
0 |
Critical |
0 |
300 |
Site |
Fabric Notification |
SM |
250 |
Running in Limited Mode |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
Licensing |
251 |
Switching to Limited Mode |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
Licensing |
252 |
License Expired |
1 |
1 |
Warning |
1 |
0 |
Grid |
Maintenance |
Licensing |
253 |
Duplicated licenses |
1 |
0 |
Critical |
1 |
0 |
Grid |
Maintenance |
Licensing |
254 |
License Limit Exceeded |
1 |
0 |
Critical |
1 |
0 |
Grid |
Maintenance |
Licensing |
255 |
License is About to Expire |
1 |
0 |
Warning |
1 |
0 |
Grid |
Maintenance |
Licensing |
256 |
Bad M_Key |
1 |
0 |
Minor |
1 |
300 |
Port |
Security |
SM |
257 |
Bad P_Key |
1 |
0 |
Minor |
1 |
300 |
Port |
Security |
SM |
258 |
Bad Q_Key |
1 |
0 |
Minor |
1 |
300 |
Port |
Security |
SM |
259 |
Bad P_Key Switch External Port |
1 |
0 |
Critical |
1 |
300 |
Port |
Security |
SM |
328 |
Link is Up |
1 |
0 |
Info |
1 |
0 |
Link |
Fabric Topology |
SM |
329 |
Link is Down |
1 |
0 |
Warning |
1 |
0 |
Site |
Fabric Topology |
SM |
331 |
Node is Down |
1 |
0 |
Warning |
1 |
0 |
Site |
Fabric Topology |
SM |
332 |
Node is Up |
1 |
0 |
Info |
1 |
300 |
Site |
Fabric Topology |
SM |
336 |
Port Action Succeeded |
1 |
0 |
Info |
1 |
0 |
Port |
Maintenance |
UFM |
337 |
Port Action Failed |
1 |
0 |
Minor |
1 |
0 |
Port |
Maintenance |
UFM |
338 |
Device Action Succeeded |
1 |
0 |
Info |
1 |
0 |
Port |
Maintenance |
UFM |
339 |
Device Action Failed |
1 |
0 |
Minor |
1 |
0 |
Port |
Maintenance |
UFM |
344 |
Partial Switch ASIC Failure |
1 |
1 |
Critical |
1 |
0 |
Switch |
Maintenance |
UFM |
370 |
Gateway Ethernet Link State Changed |
1 |
0 |
Warning |
1 |
0 |
Gateway |
Gateway |
SM |
371 |
Gateway Reregister Event Received |
1 |
0 |
Warning |
1 |
0 |
Gateway |
Gateway |
SM |
372 |
Number of Gateways Changed |
1 |
0 |
Warning |
1 |
0 |
Gateway |
Gateway |
SM |
373 |
Gateway will be Rebooted |
1 |
0 |
Warning |
1 |
0 |
Gateway |
Gateway |
SM |
374 |
Gateway Reloading Finished |
1 |
0 |
Info |
1 |
0 |
Gateway |
Gateway |
SM |
380 |
Switch Upgrade Error |
1 |
1 |
Critical |
1 |
0 |
Switch |
Maintenance |
UFM |
381 |
Switch Upgrade Failed |
1 |
0 |
Info |
1 |
0 |
Switch |
Maintenance |
UFM |
328 |
Module status NOT PRESENT |
1 |
1 |
Warning |
1 |
420 |
Switch |
Module Status |
UFM |
383 |
Host Upgrade Failed |
1 |
0 |
Info |
1 |
0 |
Computer |
Maintenance |
UFM |
384 |
Switch Module Powered Off |
1 |
1 |
Info |
1 |
420 |
Switch |
Module Status |
UFM |
385 |
Switch FW Upgrade Started |
1 |
0 |
Info |
1 |
0 |
Switch |
Maintenance |
UFM |
386 |
Switch SW Upgrade Started |
1 |
0 |
Info |
1 |
0 |
Switch |
Maintenance |
UFM |
387 |
Switch Upgrade Finished |
1 |
0 |
Info |
1 |
0 |
Switch |
Maintenance |
UFM |
388 |
Host FW Upgrade Started |
1 |
0 |
Info |
1 |
0 |
Computer |
Maintenance |
UFM |
389 |
Host SW Upgrade Started |
1 |
0 |
Info |
1 |
0 |
Computer |
Maintenance |
UFM |
391 |
Switch Module Removed |
1 |
0 |
Info |
1 |
0 |
Switch |
Fabric Notification |
Switch |
392 |
Module Temperature Threshold Reached |
1 |
0 |
Info |
40 |
0 |
Module |
Hardware |
Switch |
393 |
Switch Module Added |
1 |
0 |
Info |
1 |
0 |
Switch |
Fabric Notification |
Switch |
394 |
Module Status FAULT |
1 |
1 |
Critical |
1 |
420 |
Switch |
Module Status |
Switch |
395 |
Device Action Started |
1 |
0 |
Info |
1 |
0 |
Port |
Maintenance |
UFM |
396 |
Site Action Started |
1 |
0 |
Info |
1 |
0 |
Port |
Maintenance |
UFM |
397 |
Site Action Failed |
1 |
0 |
Minor |
1 |
0 |
Port |
Maintenance |
UFM |
398 |
Switch Chip Added |
1 |
0 |
Info |
1 |
0 |
Switch |
Fabric Notification |
Switch |
399 |
Switch Chip Removed |
1 |
0 |
Critical |
1 |
0 |
Switch |
Fabric Notification |
Switch |
403 |
Device Pending Reboot |
1 |
1 |
Warning |
0 |
300 |
Device |
Maintenance |
UFM |
404 |
System Information is missing |
1 |
1 |
Warning |
1 |
300 |
Switch |
Communication Error |
UFM |
405 |
Switch Identity Validation Failed |
1 |
1 |
Warning |
1 |
300 |
Switch |
Communication Error |
UFM |
406 |
Switch System Information is missing |
1 |
1 |
Waring |
1 |
300 |
Switch |
Communication Error |
UFM |
407 |
COMEX Ambient Temperature Threshold Reached |
1 |
1 |
Minor |
60 |
300 |
Switch |
Hardware |
Switch |
408 |
Switch is Unresponsive |
1 |
1 |
Critical |
1 |
300 |
Switch |
Communication Error |
UFM |
502 |
Device Upgrade Finished |
1 |
0 |
Info |
1 |
300 |
Device |
Maintenance |
UFM |
506 |
Device Upgrade Finished |
1 |
0 |
Info |
1 |
300 |
Device |
Maintenance |
UFM |
508 |
Core Dump Created |
1 |
1 |
Info |
1 |
300 |
Grid |
Maintenance |
UFM |
510 |
SM Failover |
0 |
1 |
Critical |
1 |
300 |
Grid |
Fabric Notification |
SM |
511 |
SM State Change |
0 |
1 |
Info |
1 |
300 |
Grid |
Fabric Notification |
SM |
512 |
SM UP |
0 |
1 |
Info |
1 |
300 |
Grid |
Fabric Notification |
SM |
513 |
SM System Log Message |
0 |
1 |
Minor |
1 |
300 |
Grid |
Fabric Notification |
SM |
514 |
SM LID Change |
0 |
1 |
Warning |
1 |
300 |
Grid |
Fabric Notification |
SM |
515 |
Fabric Health Report Info |
1 |
1 |
Info |
1 |
300 |
Grid |
Fabric Notification |
UFM |
516 |
Fabric Health Report Warning |
1 |
1 |
Warning |
1 |
300 |
Grid |
Fabric Notification |
UFM |
517 |
Fabric Health Report Error |
1 |
1 |
Critical |
1 |
300 |
Grid |
Fabric Notification |
UFM |
518 |
UFM-related process is down |
1 |
1 |
Critical |
1 |
300 |
Grid |
Maintenance |
UFM |
519 |
Logs purge failure |
1 |
1 |
Minor |
1 |
300 |
Grid |
Maintenance |
UFM |
520 |
Restart of UFM-related process succeeded |
1 |
1 |
Info |
1 |
300 |
Grid |
Maintenance |
UFM |
521 |
UFM is being stopped |
1 |
1 |
Critical |
1 |
300 |
Grid |
Maintenance |
UFM |
522 |
UFM is being restarted |
1 |
1 |
Critical |
1 |
300 |
Grid |
Maintenance |
UFM |
523 |
UFM failover is being attempted |
1 |
1 |
Info |
1 |
300 |
Grid |
Maintenance |
UFM |
524 |
UFM cannot connect to DB |
1 |
1 |
Critical |
1 |
300 |
Grid |
Maintenance |
UFM |
525 |
Disk utilization threshold reached |
1 |
1 |
Critical |
1 |
300 |
Grid |
Maintenance |
UFM |
526 |
Memory utilization threshold reached |
1 |
1 |
Critical |
1 |
300 |
Grid |
Maintenance |
UFM |
527 |
CPU utilization threshold reached |
1 |
1 |
Critical |
1 |
300 |
Grid |
Maintenance |
UFM |
528 |
Fabric interface is down |
1 |
1 |
Critical |
1 |
300 |
Grid |
Maintenance |
UFM |
529 |
UFM standby server problem |
1 |
1 |
Critical |
1 |
300 |
Grid |
Maintenance |
UFM |
530 |
SM is down |
1 |
1 |
Critical |
1 |
300 |
Grid |
Maintenance |
UFM |
531 |
DRBD Bad Condition |
1 |
1 |
Critical |
1 |
300 |
Grid |
Maintenance |
UFM |
532 |
Remote UFM-SM Sync |
1 |
1 |
Info |
1 |
0 |
Grid |
Maintenance |
UFM |
533 |
Remote UFM-SM problem |
1 |
1 |
Critical |
1 |
0 |
Site |
Maintenance |
UFM |
535 |
MH Purge Failed |
1 |
1 |
Warning |
1 |
300 |
Grid |
Maintenance |
UFM |
536 |
UFM Health Watchdog Info |
1 |
1 |
Info |
1 |
300 |
Grid |
Maintenance |
UFM |
537 |
UFM Health Watchdog Critical |
1 |
1 |
Critical |
1 |
300 |
Grid |
Maintenance |
UFM |
538 |
Time Diff Between HA Servers |
1 |
1 |
Warning |
1 |
300 |
Grid |
Maintenance |
UFM |
539 |
DRBD TCP Connection Performance |
1 |
1 |
Warning |
1 |
900 |
Grid |
Maintenance |
UFM |
540 |
Daily Report Completed successfully |
1 |
0 |
Info |
1 |
300 |
Grid |
Maintenance |
UFM |
541 |
Daily Report Completed with Error |
1 |
0 |
Minor |
1 |
300 |
Grid |
Maintenance |
UFM |
542 |
Daily Report Failed |
1 |
0 |
Critical |
1 |
300 |
Grid |
Maintenance |
UFM |
543 |
Daily Report Mail Sent successfully |
1 |
0 |
Info |
1 |
300 |
Grid |
Maintenance |
UFM |
544 |
Daily Report Mail Sent Failed |
1 |
0 |
Minor |
1 |
300 |
Grid |
Maintenance |
UFM |
545 |
SM is not responding |
1 |
1 |
Critical |
1 |
300 |
Grid |
Maintenance |
UFM |
560 |
User Connected |
Security |
UFM |
||||||
561 |
User Disconnected |
Security |
UFM |
||||||
602 |
UFM Server Failover |
1 |
1 |
Critical |
1 |
0 |
Site |
Fabric Notification |
UFM |
603 |
Events Suppression |
1 |
0 |
Critical |
0 |
300 |
Site |
Maintenance |
UFM |
604 |
Report Succeeded |
1 |
1 |
Info |
1 |
300 |
Grid |
Maintenance |
UFM |
605 |
Report Failed |
1 |
1 |
Critical |
1 |
300 |
Grid |
Maintenance |
UFM |
606 |
Correction Attempts Paused |
1 |
0 |
Warning |
1 |
0 |
Site |
Fabric Notification |
UFM |
701 |
Non-optimal Link Speed |
1 |
1 |
Minor |
1 |
0 |
Port |
Hardware |
UFM |
702 |
Unhealthy IB Port |
1 |
1 |
Warning |
1 |
0 |
Port |
Hardware |
SM |
703 |
Fabric Collector Connected |
1 |
0 |
Info |
1 |
0 |
Grid |
Maintenance |
UFM |
704 |
Fabric Collector Disconnected |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
750 |
High data retransmission count on port |
1 |
1 |
Warning |
500 |
1 |
Port |
Hardware |
SM |
901 |
Fabric Configuration Started |
0 |
1 |
Info |
1 |
0 |
Grid |
Fabric Notification |
UFM |
902 |
Fabric Configuration Completed |
0 |
1 |
Info |
1 |
0 |
Grid |
Fabric Notification |
UFM |
903 |
Fabric Configuration Failed |
0 |
1 |
Critical |
1 |
0 |
Grid |
Fabric Notification |
UFM |
904 |
Device Configuration Failure |
0 |
1 |
Critical |
1 |
0 |
Device |
Fabric Notification |
UFM |
905 |
Device Configuration Timeout |
0 |
1 |
Critical |
1 |
0 |
Device |
Fabric Notification |
UFM |
906 |
Provisioning Validation Failure |
0 |
1 |
Critical |
1 |
0 |
Grid |
Fabric Notification |
UFM |
907 |
Switch is Down |
1 |
1 |
Critical |
1 |
0 |
Site |
Fabric Topology |
UFM |
908 |
Switch is Up |
1 |
1 |
Info |
1 |
300 |
Site |
Fabric Topology |
UFM |
909 |
Director Switch is Down |
1 |
1 |
Critical |
1 |
300 |
Site |
Fabric Topology |
UFM |
910 |
Director Switch is Up |
1 |
1 |
Info |
1 |
0 |
Site |
Fabric Topology |
UFM |
911 |
Module Temperature Low Threshold Reached |
1 |
1 |
Warning |
60 |
300 |
Module |
Hardware |
Telemetry |
912 |
Module Temperature High Threshold Reached |
1 |
1 |
Critical |
60 |
300 |
Module |
Hardware |
Telemetry |
913 |
Module High Voltage |
1 |
1 |
Warning |
10 |
420 |
Switch |
Module Status |
Telemetry |
914 |
Module High Current |
1 |
1 |
Warning |
10 |
420 |
Switch |
Module Status |
Telemetry |
915 |
BER_ERROR |
1 |
1 |
Critical |
1e-8 |
420 |
Port |
Hardware |
Telemetry |
916 |
BER_WARNING |
1 |
1 |
Warning |
1e-13 |
420 |
Port |
Hardware |
Telemetry |
917 |
SYMBOL_BER_ERROR |
1 |
1 |
Critical |
10 |
420 |
Port |
Hardware |
Telemetry |
918 |
High Symbol BER reported |
1 |
1 |
Warning |
10 |
420 |
Port |
Hardware |
Telemetry |
919 |
Cable Temperature High |
1 |
1 |
Critical |
0 |
0 |
Port |
Hardware |
Telemetry |
920 |
Cable Temperature Low |
1 |
1 |
Critical |
0 |
0 |
Port |
Hardware |
Telemetry |
1300 |
SM_SAKEY_VIOLATION |
1 |
1 |
Warning |
5300 |
Port |
Security |
SM |
|
1301 |
SM_SGID_SPOOFED |
1 |
1 |
Warning |
5300 |
Port |
Security |
SM |
|
1302 |
SM_RATE_LIMIT_EXCEEDED |
1 |
1 |
Warning |
5300 |
Port |
Security |
SM |
|
1303 |
SM_MULTICAST_GROUPS_LIMIT_EXCEEDED |
1 |
1 |
Warning |
5300 |
Port |
Security |
SM |
|
1304 |
SM_SERVICES_LIMIT_EXCEEDED |
1 |
1 |
Warning |
5300 |
Port |
Security |
SM |
|
1305 |
SM_EVENT_SUBSCRIPTION_LIMIT_EXCEEDED |
1 |
1 |
Warning |
5300 |
Port |
Security |
SM |
|
1306 |
Unallowed SM was detected in the fabric |
1 |
1 |
Warning |
0 |
300 |
Port |
Fabric Notification |
SM |
1307 |
SMInfo SET request was received from unallowed SM |
1 |
1 |
Warning |
0 |
300 |
Port |
Fabric Notification |
SM |
1309 |
SM was detected with non-matching SMKey |
1 |
1 |
Warning |
0 |
300 |
Port |
Fabric Notification |
SM |
1310 |
Duplicated node GUID was detected |
1 |
1 |
Critical |
1 |
0 |
Device |
Fabric Notification |
SM |
1311 |
Duplicated port GUID was detected |
1 |
1 |
Critical |
1 |
0 |
Port |
Fabric Notification |
SM |
1312 |
Switch was Rebooted |
1 |
1 |
Info |
1 |
0 |
Device |
Fabric Notification |
UFM |
1315 |
Topo Config File Error |
1 |
1 |
Critical |
1 |
0 |
Grid |
Fabric Notification |
UFM |
1316 |
Topo Config Subnet Mismatch |
1 |
1 |
Critical |
1 |
0 |
Grid |
Fabric Notification |
Topodiff |
1400 |
High Ambient Temperature |
1 |
1 |
Warning |
0 |
86400 |
Switch |
Hardware |
Switch |
1401 |
High Fluid Temperature |
1 |
1 |
Warning |
0 |
86400 |
Switch |
Hardware |
Switch |
1402 |
Low Fluid Level |
1 |
1 |
Warning |
0 |
86400 |
Switch |
Hardware |
Switch |
1403 |
Low Supply Pressure |
1 |
1 |
Warning |
0 |
86400 |
Switch |
Hardware |
Switch |
1404 |
High Supply Pressure |
1 |
1 |
Warning |
0 |
86400 |
Switch |
Hardware |
Switch |
1405 |
Low Return Pressure |
1 |
1 |
Warning |
0 |
86400 |
Switch |
Hardware |
Switch |
1406 |
High Return Pressure |
1 |
1 |
Warning |
0 |
86400 |
Switch |
Hardware |
Switch |
1407 |
High Differential Pressure |
1 |
1 |
Warning |
0 |
86400 |
Switch |
Hardware |
Switch |
1408 |
Low Differential Pressure |
1 |
1 |
Warning |
0 |
86400 |
Switch |
Hardware |
Switch |
1409 |
System Fail Safe |
1 |
1 |
Warning |
0 |
86400 |
Switch |
Hardware |
Switch |
1410 |
Fault Critical |
1 |
1 |
Critical |
0 |
86400 |
Switch |
Hardware |
Switch |
1411 |
Fault Pump1 |
1 |
1 |
Critical |
0 |
86400 |
Switch |
Hardware |
Switch |
1412 |
Fault Pump2 |
1 |
1 |
Critical |
0 |
86400 |
Switch |
Hardware |
Switch |
1413 |
Fault Fluid Level Critical |
1 |
1 |
Critical |
0 |
86400 |
Switch |
Hardware |
Switch |
1414 |
Fault Fluid Over Temperature |
1 |
1 |
Critical |
0 |
86400 |
Switch |
Hardware |
Switch |
1415 |
Fault Primary DC |
1 |
1 |
Critical |
0 |
86400 |
Switch |
Hardware |
Switch |
1416 |
Fault Redundant DC |
1 |
1 |
Critical |
0 |
86400 |
Switch |
Hardware |
Switch |
1417 |
Fault Fluid Leak |
1 |
1 |
Critical |
0 |
86400 |
Switch |
Hardware |
Switch |
1418 |
Fault Sensor Failure |
1 |
1 |
Critical |
0 |
86400 |
Switch |
Hardware |
Switch |
1419 |
Cooling Device Monitoring Error |
1 |
0 |
Critical |
0 |
1 |
Grid |
Hardware |
Switch |
1420 |
Cooling Device Communication Error |
1 |
1 |
Critical |
0 |
86400 |
Switch |
Hardware |
Switch |
1500 |
New cable detected |
1 |
0 |
Info |
1 |
0 |
Link |
Security |
UFM |
1502 |
Cable detected in a new location |
1 |
0 |
Warning |
1 |
0 |
Link |
Security |
UFM |
1503 |
Duplicate Cable Detected |
1 |
0 |
Critical |
1 |
0 |
Link |
Security |
UFM |
1315 |
Topo Config File Error |
1 |
1 |
Critical |
1 |
0 |
Grid |
Fabric Notification |
UFM |
1504 |
SHARP Allocation Succeeded |
1 |
1 |
Info |
1 |
0 |
Grid |
SHARP |
SHARP |
1505 |
SHARP Allocation Failed |
1 |
0 |
Warning |
1 |
0 |
Grid |
SHARP |
SHARP |
1506 |
SHARP Deallocation Succeeded |
1 |
0 |
Info |
1 |
0 |
Grid |
SHARP |
SHARP |
1507 |
SHARP Deallocation Failed |
1 |
0 |
Warning |
1 |
0 |
Grid |
SHARP |
SHARP |
1508 |
Device Collect System Dump Started |
1 |
0 |
Info |
1 |
300 |
Device |
Maintenance |
UFM |
1509 |
Device Collect System Dump Finished |
1 |
0 |
Info |
1 |
300 |
Device |
Maintenance |
UFM |
1510 |
Device Collect System Dump Error |
1 |
0 |
Critical |
1 |
300 |
Device |
Maintenance |
UFM |
1511 |
Virtual Port Added |
1 |
0 |
Info |
1 |
0 |
Port |
Fabric Notification |
SM |
1512 |
Virtual Port Removed |
1 |
0 |
Warning |
1 |
0 |
Port |
Fabric Notification |
SM |
1513 |
Burn Cables Transceivers Started |
1 |
0 |
Info |
1 |
0 |
Device |
Maintenance |
UFM |
1514 |
Burn Cables Transceivers Finished |
1 |
0 |
Info |
1 |
0 |
Device |
Maintenance |
UFM |
1515 |
Burn Cables Transceivers Failed |
1 |
0 |
Warning |
1 |
0 |
Device |
Maintenance |
UFM |
1516 |
Activate Cables Transceivers FW Finished |
1 |
0 |
Info |
1 |
0 |
Device |
Maintenance |
UFM |
1517 |
Activate Cables Transceivers FW Failed |
1 |
0 |
Warning |
1 |
0 |
Device |
Maintenance |
UFM |
1520 |
Aggregation Node Discovery Failed |
1 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1521 |
Job Started |
1 |
0 |
Info |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1522 |
Job Ended |
1 |
0 |
Info |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1523 |
Job Start Failed |
1 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1524 |
Job Error |
1 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1525 |
Trap QP Error |
1 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1526 |
Trap Invalid Request |
1 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1527 |
Trap Sharp Error |
1 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1528 |
Trap QP Alloc timeout |
1 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1529 |
Trap AMKey Violation |
1 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1530 |
Unsupported Trap |
1 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1531 |
Reservation Updated |
1 |
0 |
Info |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1532 |
Sharp is not Responding |
1 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1533 |
Agg Node Active |
1 |
0 |
Info |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1534 |
Agg Node Inactive |
1 |
0 |
Warning |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1535 |
Trap AMKey Violation Triggered by AM |
1 |
0 |
Warning |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
1550 |
Guids Were Added to Pkey |
1 |
0 |
Info |
1 |
0 |
Port |
Fabric Notification |
UFM |
1551 |
Guids Were Removed from Pkey |
1 |
0 |
Info |
1 |
0 |
Port |
Fabric Notification |
UFM |
1600 |
VS/CC Classes Key Violation |
Security |
SM |
||||||
1602 |
PCI Speed Degradation Warning |
1 |
1 |
Warning |
1 |
0 |
Port |
Fabric Notification |
UFM |
1603 |
PCI Width Degradation Warning |
1 |
1 |
Warning |
1 |
0 |
Port |
Fabric Notification |
UFM |