Threshold-Crossing Events Reference
This reference lists the threshold-based events that UFM supports, each including a set of attributes listed below. You can view these messages through Events & Alarms. For details about configuring notifications for these events, refer to Configuring Event Management.
Event ID: Unique event identifier
Event Name: Short description of the event
To log: A flag which defines whether the event will be sent to UFM events log or not (1 or 0, respectively).
Alarm: A flag which defines whether UFM alarm is generated when the specified event is triggered by UFM (1 means an alarm is generated). Alarms are used to allow a notification with significant indication.
Default Severity: Indicates the alarm severity (Info, Warning, Minor, Critical)
Default Threshold: Event dependent threshold (for example, event occurrence, counter threshold or temperature threshold).
Default TTL: TTL (Alarm Time to Live) sets the time during which the alarm on the event is visible on UFM Web UI. TTL is defined in seconds. CAUTION: Setting the TTL to 0 makes the alarm permanent, meaning that the alarm does not disappear from the Web UI until cleared manually.
Related Object: The object (context) to which the UFM event is related to (port, switch, gateway, grid, etc).
Category: Indicates the category to which the event is related to.
Source: Indicates the origin source of the specified event (SM, Telemetry, Licensing, UFM)
For information about defining event policy, see Configuring Event Management.
Event ID  | Event Name  | To Log  | Alarm  | Default Severity  | Default Threshold  | Default TTL  | Related Object  | Category  | Source  | 
64  | GID Address In Service  | 1  | 0  | Info  | 1  | 300  | Port  | Fabric Notification  | SM  | 
65  | GID Address Out of Service  | 1  | 0  | Warning  | 1  | 300  | Port  | Fabric Notification  | SM  | 
66  | New MCast Group Created  | 1  | 0  | Info  | 1  | 300  | Port  | Fabric Notification  | SM  | 
67  | MCast Group Deleted  | 1  | 0  | Info  | 1  | 300  | Port  | Fabric Notification  | SM  | 
110  | Symbol Error  | 1  | 1  | Warning  | 200  | 300  | Port  | Hardware  | Telemetry  | 
111  | Link Error Recovery  | 1  | 1  | Minor  | 1  | 300  | Port  | Hardware  | Telemetry  | 
112  | Link Downed  | 1  | 1  | Critical  | 1  | 300  | Port  | Hardware  | Telemetry  | 
113  | Port Receive Errors  | 1  | 1  | Minor  | 5  | 300  | Port  | Hardware  | Telemetry  | 
114  | Port Receive Remote Physical Errors  | 0  | 0  | Minor  | 5  | 300  | Port  | Hardware  | Telemetry  | 
115  | Port Receive Switch Relay Errors  | 1  | 1  | Minor  | 999  | 300  | Port  | Fabric Configuration  | Telemetry  | 
116  | Port Xmit Discards  | 1  | 1  | Minor  | 200  | 300  | Port  | Communication Error  | Telemetry  | 
117  | Port Xmit Constraint Errors  | 1  | 1  | Minor  | 200  | 300  | Port  | Communication Error  | Telemetry  | 
118  | Port Receive Constraint Errors  | 1  | 1  | Minor  | 200  | 300  | Port  | Communication Error  | Telemetry  | 
119  | Local Link Integrity Errors  | 1  | 1  | Minor  | 5  | 300  | Port  | Hardware  | Telemetry  | 
120  | Excessive Buffer Overrun Errors  | 1  | 1  | Minor  | 100  | 300  | Port  | Communication Error  | Telemetry  | 
121  | VL15 Dropped  | 1  | 1  | Minor  | 50  | 300  | Port  | Communication Error  | Telemetry  | 
122  | Congested Bandwidth (%) Threshold Reached  | 1  | 1  | Minor  | 10  | 300  | Port  | Hardware  | Telemetry  | 
123  | Port Bandwidth (%) Threshold Reached  | 1  | 1  | Minor  | 95  | 300  | Port  | Communication Error  | Telemetry  | 
130  | Non-optimal link width  | 1  | 1  | Minor  | 1  | 0  | Port  | Hardware  | SM  | 
134  | T4 Port Congested Bandwidth  | 1  | 1  | Warning  | 10  | 300  | Port  | Communication Error  | Telemetry  | 
141  | Flow Control Update Watchdog Timer Expired  | 1  | 0  | Warning  | 1  | 300  | Port  | Hardware  | SM  | 
144  | Capability Mask Modified  | 1  | 0  | Info  | 1  | 300  | Port  | Fabric Notification  | SM  | 
145  | System Image GUID changed  | 1  | 0  | Info  | 1  | 300  | Port  | Communication Error  | SM  | 
156  | Link Speed Enforcement Disabled  | 1  | 0  | Critical  | 0  | 300  | Site  | Fabric Notification  | SM  | 
250  | Running in Limited Mode  | 1  | 1  | Critical  | 1  | 0  | Grid  | Maintenance  | Licensing  | 
251  | Switching to Limited Mode  | 1  | 1  | Critical  | 1  | 0  | Grid  | Maintenance  | Licensing  | 
252  | License Expired  | 1  | 1  | Warning  | 1  | 0  | Grid  | Maintenance  | Licensing  | 
253  | Duplicated licenses  | 1  | 0  | Critical  | 1  | 0  | Grid  | Maintenance  | Licensing  | 
254  | License Limit Exceeded  | 1  | 0  | Critical  | 1  | 0  | Grid  | Maintenance  | Licensing  | 
255  | License is About to Expire  | 1  | 0  | Warning  | 1  | 0  | Grid  | Maintenance  | Licensing  | 
256  | Bad M_Key  | 1  | 0  | Minor  | 1  | 300  | Port  | Security  | SM  | 
257  | Bad P_Key  | 1  | 0  | Minor  | 1  | 300  | Port  | Security  | SM  | 
258  | Bad Q_Key  | 1  | 0  | Minor  | 1  | 300  | Port  | Security  | SM  | 
259  | Bad P_Key Switch External Port  | 1  | 0  | Critical  | 1  | 300  | Port  | Security  | SM  | 
328  | Link is Up  | 1  | 0  | Info  | 1  | 0  | Link  | Fabric Topology  | SM  | 
329  | Link is Down  | 1  | 0  | Warning  | 1  | 0  | Site  | Fabric Topology  | SM  | 
331  | Node is Down  | 1  | 0  | Warning  | 1  | 0  | Site  | Fabric Topology  | SM  | 
332  | Node is Up  | 1  | 0  | Info  | 1  | 300  | Site  | Fabric Topology  | SM  | 
336  | Port Action Succeeded  | 1  | 0  | Info  | 1  | 0  | Port  | Maintenance  | UFM  | 
337  | Port Action Failed  | 1  | 0  | Minor  | 1  | 0  | Port  | Maintenance  | UFM  | 
338  | Device Action Succeeded  | 1  | 0  | Info  | 1  | 0  | Port  | Maintenance  | UFM  | 
339  | Device Action Failed  | 1  | 0  | Minor  | 1  | 0  | Port  | Maintenance  | UFM  | 
344  | Partial Switch ASIC Failure  | 1  | 1  | Critical  | 1  | 0  | Switch  | Maintenance  | UFM  | 
370  | Gateway Ethernet Link State Changed  | 1  | 0  | Warning  | 1  | 0  | Gateway  | Gateway  | SM  | 
371  | Gateway Reregister Event Received  | 1  | 0  | Warning  | 1  | 0  | Gateway  | Gateway  | SM  | 
372  | Number of Gateways Changed  | 1  | 0  | Warning  | 1  | 0  | Gateway  | Gateway  | SM  | 
373  | Gateway will be Rebooted  | 1  | 0  | Warning  | 1  | 0  | Gateway  | Gateway  | SM  | 
374  | Gateway Reloading Finished  | 1  | 0  | Info  | 1  | 0  | Gateway  | Gateway  | SM  | 
380  | Switch Upgrade Error  | 1  | 1  | Critical  | 1  | 0  | Switch  | Maintenance  | UFM  | 
381  | Switch Upgrade Failed  | 1  | 0  | Info  | 1  | 0  | Switch  | Maintenance  | UFM  | 
328  | Module status NOT PRESENT  | 1  | 1  | Warning  | 1  | 420  | Switch  | Module Status  | UFM  | 
383  | Host Upgrade Failed  | 1  | 0  | Info  | 1  | 0  | Computer  | Maintenance  | UFM  | 
384  | Switch Module Powered Off  | 1  | 1  | Info  | 1  | 420  | Switch  | Module Status  | UFM  | 
385  | Switch FW Upgrade Started  | 1  | 0  | Info  | 1  | 0  | Switch  | Maintenance  | UFM  | 
386  | Switch SW Upgrade Started  | 1  | 0  | Info  | 1  | 0  | Switch  | Maintenance  | UFM  | 
387  | Switch Upgrade Finished  | 1  | 0  | Info  | 1  | 0  | Switch  | Maintenance  | UFM  | 
388  | Host FW Upgrade Started  | 1  | 0  | Info  | 1  | 0  | Computer  | Maintenance  | UFM  | 
389  | Host SW Upgrade Started  | 1  | 0  | Info  | 1  | 0  | Computer  | Maintenance  | UFM  | 
391  | Switch Module Removed  | 1  | 0  | Info  | 1  | 0  | Switch  | Fabric Notification  | Switch  | 
392  | Module Temperature Threshold Reached  | 1  | 0  | Info  | 40  | 0  | Module  | Hardware  | Switch  | 
393  | Switch Module Added  | 1  | 0  | Info  | 1  | 0  | Switch  | Fabric Notification  | Switch  | 
394  | Module Status FAULT  | 1  | 1  | Critical  | 1  | 420  | Switch  | Module Status  | Switch  | 
395  | Device Action Started  | 1  | 0  | Info  | 1  | 0  | Port  | Maintenance  | UFM  | 
396  | Site Action Started  | 1  | 0  | Info  | 1  | 0  | Port  | Maintenance  | UFM  | 
397  | Site Action Failed  | 1  | 0  | Minor  | 1  | 0  | Port  | Maintenance  | UFM  | 
398  | Switch Chip Added  | 1  | 0  | Info  | 1  | 0  | Switch  | Fabric Notification  | Switch  | 
399  | Switch Chip Removed  | 1  | 0  | Critical  | 1  | 0  | Switch  | Fabric Notification  | Switch  | 
403  | Device Pending Reboot  | 1  | 1  | Warning  | 0  | 300  | Device  | Maintenance  | UFM  | 
404  | System Information is missing  | 1  | 1  | Warning  | 1  | 300  | Switch  | Communication Error  | UFM  | 
405  | Switch Identity Validation Failed  | 1  | 1  | Warning  | 1  | 300  | Switch  | Communication Error  | UFM  | 
406  | Switch System Information is missing  | 1  | 1  | Waring  | 1  | 300  | Switch  | Communication Error  | UFM  | 
407  | COMEX Ambient Temperature Threshold Reached  | 1  | 1  | Minor  | 60  | 300  | Switch  | Hardware  | Switch  | 
408  | Switch is Unresponsive  | 1  | 1  | Critical  | 1  | 300  | Switch  | Communication Error  | UFM  | 
502  | Device Upgrade Finished  | 1  | 0  | Info  | 1  | 300  | Device  | Maintenance  | UFM  | 
506  | Device Upgrade Finished  | 1  | 0  | Info  | 1  | 300  | Device  | Maintenance  | UFM  | 
508  | Core Dump Created  | 1  | 1  | Info  | 1  | 300  | Grid  | Maintenance  | UFM  | 
510  | SM Failover  | 0  | 1  | Critical  | 1  | 300  | Grid  | Fabric Notification  | SM  | 
511  | SM State Change  | 0  | 1  | Info  | 1  | 300  | Grid  | Fabric Notification  | SM  | 
512  | SM UP  | 0  | 1  | Info  | 1  | 300  | Grid  | Fabric Notification  | SM  | 
513  | SM System Log Message  | 0  | 1  | Minor  | 1  | 300  | Grid  | Fabric Notification  | SM  | 
514  | SM LID Change  | 0  | 1  | Warning  | 1  | 300  | Grid  | Fabric Notification  | SM  | 
515  | Fabric Health Report Info  | 1  | 1  | Info  | 1  | 300  | Grid  | Fabric Notification  | UFM  | 
516  | Fabric Health Report Warning  | 1  | 1  | Warning  | 1  | 300  | Grid  | Fabric Notification  | UFM  | 
517  | Fabric Health Report Error  | 1  | 1  | Critical  | 1  | 300  | Grid  | Fabric Notification  | UFM  | 
518  | UFM-related process is down  | 1  | 1  | Critical  | 1  | 300  | Grid  | Maintenance  | UFM  | 
519  | Logs purge failure  | 1  | 1  | Minor  | 1  | 300  | Grid  | Maintenance  | UFM  | 
520  | Restart of UFM-related process succeeded  | 1  | 1  | Info  | 1  | 300  | Grid  | Maintenance  | UFM  | 
521  | UFM is being stopped  | 1  | 1  | Critical  | 1  | 300  | Grid  | Maintenance  | UFM  | 
522  | UFM is being restarted  | 1  | 1  | Critical  | 1  | 300  | Grid  | Maintenance  | UFM  | 
523  | UFM failover is being attempted  | 1  | 1  | Info  | 1  | 300  | Grid  | Maintenance  | UFM  | 
524  | UFM cannot connect to DB  | 1  | 1  | Critical  | 1  | 300  | Grid  | Maintenance  | UFM  | 
525  | Disk utilization threshold reached  | 1  | 1  | Critical  | 1  | 300  | Grid  | Maintenance  | UFM  | 
526  | Memory utilization threshold reached  | 1  | 1  | Critical  | 1  | 300  | Grid  | Maintenance  | UFM  | 
527  | CPU utilization threshold reached  | 1  | 1  | Critical  | 1  | 300  | Grid  | Maintenance  | UFM  | 
528  | Fabric interface is down  | 1  | 1  | Critical  | 1  | 300  | Grid  | Maintenance  | UFM  | 
529  | UFM standby server problem  | 1  | 1  | Critical  | 1  | 300  | Grid  | Maintenance  | UFM  | 
530  | SM is down  | 1  | 1  | Critical  | 1  | 300  | Grid  | Maintenance  | UFM  | 
531  | DRBD Bad Condition  | 1  | 1  | Critical  | 1  | 300  | Grid  | Maintenance  | UFM  | 
532  | Remote UFM-SM Sync  | 1  | 1  | Info  | 1  | 0  | Grid  | Maintenance  | UFM  | 
533  | Remote UFM-SM problem  | 1  | 1  | Critical  | 1  | 0  | Site  | Maintenance  | UFM  | 
535  | MH Purge Failed  | 1  | 1  | Warning  | 1  | 300  | Grid  | Maintenance  | UFM  | 
536  | UFM Health Watchdog Info  | 1  | 1  | Info  | 1  | 300  | Grid  | Maintenance  | UFM  | 
537  | UFM Health Watchdog Critical  | 1  | 1  | Critical  | 1  | 300  | Grid  | Maintenance  | UFM  | 
538  | Time Diff Between HA Servers  | 1  | 1  | Warning  | 1  | 300  | Grid  | Maintenance  | UFM  | 
539  | DRBD TCP Connection Performance  | 1  | 1  | Warning  | 1  | 900  | Grid  | Maintenance  | UFM  | 
540  | Daily Report Completed successfully  | 1  | 0  | Info  | 1  | 300  | Grid  | Maintenance  | UFM  | 
541  | Daily Report Completed with Error  | 1  | 0  | Minor  | 1  | 300  | Grid  | Maintenance  | UFM  | 
542  | Daily Report Failed  | 1  | 0  | Critical  | 1  | 300  | Grid  | Maintenance  | UFM  | 
543  | Daily Report Mail Sent successfully  | 1  | 0  | Info  | 1  | 300  | Grid  | Maintenance  | UFM  | 
544  | Daily Report Mail Sent Failed  | 1  | 0  | Minor  | 1  | 300  | Grid  | Maintenance  | UFM  | 
545  | SM is not responding  | 1  | 1  | Critical  | 1  | 300  | Grid  | Maintenance  | UFM  | 
560  | User Connected  | Security  | UFM  | ||||||
561  | User Disconnected  | Security  | UFM  | ||||||
602  | UFM Server Failover  | 1  | 1  | Critical  | 1  | 0  | Site  | Fabric Notification  | UFM  | 
603  | Events Suppression  | 1  | 0  | Critical  | 0  | 300  | Site  | Maintenance  | UFM  | 
604  | Report Succeeded  | 1  | 1  | Info  | 1  | 300  | Grid  | Maintenance  | UFM  | 
605  | Report Failed  | 1  | 1  | Critical  | 1  | 300  | Grid  | Maintenance  | UFM  | 
606  | Correction Attempts Paused  | 1  | 0  | Warning  | 1  | 0  | Site  | Fabric Notification  | UFM  | 
701  | Non-optimal Link Speed  | 1  | 1  | Minor  | 1  | 0  | Port  | Hardware  | UFM  | 
702  | Unhealthy IB Port  | 1  | 1  | Warning  | 1  | 0  | Port  | Hardware  | SM  | 
703  | Fabric Collector Connected  | 1  | 0  | Info  | 1  | 0  | Grid  | Maintenance  | UFM  | 
704  | Fabric Collector Disconnected  | 1  | 1  | Critical  | 1  | 0  | Grid  | Maintenance  | UFM  | 
750  | High data retransmission count on port  | 1  | 1  | Warning  | 500  | 1  | Port  | Hardware  | SM  | 
901  | Fabric Configuration Started  | 0  | 1  | Info  | 1  | 0  | Grid  | Fabric Notification  | UFM  | 
902  | Fabric Configuration Completed  | 0  | 1  | Info  | 1  | 0  | Grid  | Fabric Notification  | UFM  | 
903  | Fabric Configuration Failed  | 0  | 1  | Critical  | 1  | 0  | Grid  | Fabric Notification  | UFM  | 
904  | Device Configuration Failure  | 0  | 1  | Critical  | 1  | 0  | Device  | Fabric Notification  | UFM  | 
905  | Device Configuration Timeout  | 0  | 1  | Critical  | 1  | 0  | Device  | Fabric Notification  | UFM  | 
906  | Provisioning Validation Failure  | 0  | 1  | Critical  | 1  | 0  | Grid  | Fabric Notification  | UFM  | 
907  | Switch is Down  | 1  | 1  | Critical  | 1  | 0  | Site  | Fabric Topology  | UFM  | 
908  | Switch is Up  | 1  | 1  | Info  | 1  | 300  | Site  | Fabric Topology  | UFM  | 
909  | Director Switch is Down  | 1  | 1  | Critical  | 1  | 300  | Site  | Fabric Topology  | UFM  | 
910  | Director Switch is Up  | 1  | 1  | Info  | 1  | 0  | Site  | Fabric Topology  | UFM  | 
911  | Module Temperature Low Threshold Reached  | 1  | 1  | Warning  | 60  | 300  | Module  | Hardware  | Telemetry  | 
912  | Module Temperature High Threshold Reached  | 1  | 1  | Critical  | 60  | 300  | Module  | Hardware  | Telemetry  | 
913  | Module High Voltage  | 1  | 1  | Warning  | 10  | 420  | Switch  | Module Status  | Telemetry  | 
914  | Module High Current  | 1  | 1  | Warning  | 10  | 420  | Switch  | Module Status  | Telemetry  | 
915  | BER_ERROR  | 1  | 1  | Critical  | 1e-8  | 420  | Port  | Hardware  | Telemetry  | 
916  | BER_WARNING  | 1  | 1  | Warning  | 1e-13  | 420  | Port  | Hardware  | Telemetry  | 
917  | SYMBOL_BER_ERROR  | 1  | 1  | Critical  | 10  | 420  | Port  | Hardware  | Telemetry  | 
918  | High Symbol BER reported  | 1  | 1  | Warning  | 10  | 420  | Port  | Hardware  | Telemetry  | 
919  | Cable Temperature High  | 1  | 1  | Critical  | 0  | 0  | Port  | Hardware  | Telemetry  | 
920  | Cable Temperature Low  | 1  | 1  | Critical  | 0  | 0  | Port  | Hardware  | Telemetry  | 
1300  | SM_SAKEY_VIOLATION  | 1  | 1  | Warning  | 5300  | Port  | Security  | SM  | |
1301  | SM_SGID_SPOOFED  | 1  | 1  | Warning  | 5300  | Port  | Security  | SM  | |
1302  | SM_RATE_LIMIT_EXCEEDED  | 1  | 1  | Warning  | 5300  | Port  | Security  | SM  | |
1303  | SM_MULTICAST_GROUPS_LIMIT_EXCEEDED  | 1  | 1  | Warning  | 5300  | Port  | Security  | SM  | |
1304  | SM_SERVICES_LIMIT_EXCEEDED  | 1  | 1  | Warning  | 5300  | Port  | Security  | SM  | |
1305  | SM_EVENT_SUBSCRIPTION_LIMIT_EXCEEDED  | 1  | 1  | Warning  | 5300  | Port  | Security  | SM  | |
1306  | Unallowed SM was detected in the fabric  | 1  | 1  | Warning  | 0  | 300  | Port  | Fabric Notification  | SM  | 
1307  | SMInfo SET request was received from unallowed SM  | 1  | 1  | Warning  | 0  | 300  | Port  | Fabric Notification  | SM  | 
1309  | SM was detected with non-matching SMKey  | 1  | 1  | Warning  | 0  | 300  | Port  | Fabric Notification  | SM  | 
1310  | Duplicated node GUID was detected  | 1  | 1  | Critical  | 1  | 0  | Device  | Fabric Notification  | SM  | 
1311  | Duplicated port GUID was detected  | 1  | 1  | Critical  | 1  | 0  | Port  | Fabric Notification  | SM  | 
1312  | Switch was Rebooted  | 1  | 1  | Info  | 1  | 0  | Device  | Fabric Notification  | UFM  | 
1315  | Topo Config File Error  | 1  | 1  | Critical  | 1  | 0  | Grid  | Fabric Notification  | UFM  | 
1316  | Topo Config Subnet Mismatch  | 1  | 1  | Critical  | 1  | 0  | Grid  | Fabric Notification  | Topodiff  | 
1400  | High Ambient Temperature  | 1  | 1  | Warning  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1401  | High Fluid Temperature  | 1  | 1  | Warning  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1402  | Low Fluid Level  | 1  | 1  | Warning  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1403  | Low Supply Pressure  | 1  | 1  | Warning  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1404  | High Supply Pressure  | 1  | 1  | Warning  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1405  | Low Return Pressure  | 1  | 1  | Warning  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1406  | High Return Pressure  | 1  | 1  | Warning  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1407  | High Differential Pressure  | 1  | 1  | Warning  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1408  | Low Differential Pressure  | 1  | 1  | Warning  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1409  | System Fail Safe  | 1  | 1  | Warning  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1410  | Fault Critical  | 1  | 1  | Critical  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1411  | Fault Pump1  | 1  | 1  | Critical  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1412  | Fault Pump2  | 1  | 1  | Critical  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1413  | Fault Fluid Level Critical  | 1  | 1  | Critical  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1414  | Fault Fluid Over Temperature  | 1  | 1  | Critical  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1415  | Fault Primary DC  | 1  | 1  | Critical  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1416  | Fault Redundant DC  | 1  | 1  | Critical  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1417  | Fault Fluid Leak  | 1  | 1  | Critical  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1418  | Fault Sensor Failure  | 1  | 1  | Critical  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1419  | Cooling Device Monitoring Error  | 1  | 0  | Critical  | 0  | 1  | Grid  | Hardware  | Switch  | 
1420  | Cooling Device Communication Error  | 1  | 1  | Critical  | 0  | 86400  | Switch  | Hardware  | Switch  | 
1500  | New cable detected  | 1  | 0  | Info  | 1  | 0  | Link  | Security  | UFM  | 
1502  | Cable detected in a new location  | 1  | 0  | Warning  | 1  | 0  | Link  | Security  | UFM  | 
1503  | Duplicate Cable Detected  | 1  | 0  | Critical  | 1  | 0  | Link  | Security  | UFM  | 
1315  | Topo Config File Error  | 1  | 1  | Critical  | 1  | 0  | Grid  | Fabric Notification  | UFM  | 
1504  | SHARP Allocation Succeeded  | 1  | 1  | Info  | 1  | 0  | Grid  | SHARP  | SHARP  | 
1505  | SHARP Allocation Failed  | 1  | 0  | Warning  | 1  | 0  | Grid  | SHARP  | SHARP  | 
1506  | SHARP Deallocation Succeeded  | 1  | 0  | Info  | 1  | 0  | Grid  | SHARP  | SHARP  | 
1507  | SHARP Deallocation Failed  | 1  | 0  | Warning  | 1  | 0  | Grid  | SHARP  | SHARP  | 
1508  | Device Collect System Dump Started  | 1  | 0  | Info  | 1  | 300  | Device  | Maintenance  | UFM  | 
1509  | Device Collect System Dump Finished  | 1  | 0  | Info  | 1  | 300  | Device  | Maintenance  | UFM  | 
1510  | Device Collect System Dump Error  | 1  | 0  | Critical  | 1  | 300  | Device  | Maintenance  | UFM  | 
1511  | Virtual Port Added  | 1  | 0  | Info  | 1  | 0  | Port  | Fabric Notification  | SM  | 
1512  | Virtual Port Removed  | 1  | 0  | Warning  | 1  | 0  | Port  | Fabric Notification  | SM  | 
1513  | Burn Cables Transceivers Started  | 1  | 0  | Info  | 1  | 0  | Device  | Maintenance  | UFM  | 
1514  | Burn Cables Transceivers Finished  | 1  | 0  | Info  | 1  | 0  | Device  | Maintenance  | UFM  | 
1515  | Burn Cables Transceivers Failed  | 1  | 0  | Warning  | 1  | 0  | Device  | Maintenance  | UFM  | 
1516  | Activate Cables Transceivers FW Finished  | 1  | 0  | Info  | 1  | 0  | Device  | Maintenance  | UFM  | 
1517  | Activate Cables Transceivers FW Failed  | 1  | 0  | Warning  | 1  | 0  | Device  | Maintenance  | UFM  | 
1520  | Aggregation Node Discovery Failed  | 1  | 0  | Critical  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1521  | Job Started  | 1  | 0  | Info  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1522  | Job Ended  | 1  | 0  | Info  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1523  | Job Start Failed  | 1  | 0  | Critical  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1524  | Job Error  | 1  | 0  | Critical  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1525  | Trap QP Error  | 1  | 0  | Critical  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1526  | Trap Invalid Request  | 1  | 0  | Critical  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1527  | Trap Sharp Error  | 1  | 0  | Critical  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1528  | Trap QP Alloc timeout  | 1  | 0  | Critical  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1529  | Trap AMKey Violation  | 1  | 0  | Critical  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1530  | Unsupported Trap  | 1  | 0  | Critical  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1531  | Reservation Updated  | 1  | 0  | Info  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1532  | Sharp is not Responding  | 1  | 0  | Critical  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1533  | Agg Node Active  | 1  | 0  | Info  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1534  | Agg Node Inactive  | 1  | 0  | Warning  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1535  | Trap AMKey Violation Triggered by AM  | 1  | 0  | Warning  | 1  | 0  | SHARP AM  | SHARP  | SHARP  | 
1550  | Guids Were Added to Pkey  | 1  | 0  | Info  | 1  | 0  | Port  | Fabric Notification  | UFM  | 
1551  | Guids Were Removed from Pkey  | 1  | 0  | Info  | 1  | 0  | Port  | Fabric Notification  | UFM  | 
1600  | VS/CC Classes Key Violation  | Security  | SM  | ||||||
1602  | PCI Speed Degradation Warning  | 1  | 1  | Warning  | 1  | 0  | Port  | Fabric Notification  | UFM  | 
1603  | PCI Width Degradation Warning  | 1  | 1  | Warning  | 1  | 0  | Port  | Fabric Notification  | UFM  | 
1609  | In Service Switch Upgrade isolate action  | 1  | 1  | Warning  | 1  | 0  | Switch  | Hardware  | SM  | 
1610  | In Service Switch Upgrade Deisolate action  | 1  | 1  | Warning  | 1  | 0  | Switch  | Hardware  | SM  |