Settings and Configuration
Inside the container, the directory /config
contains the configuration files for the NVIDIA® UFM® Telemetry application. The file launch_ibdiagnet_config.ini
is the main configuration file.
The basic configurations of launch_ibdiagnet_config.ini
are listed in the following table.
Section |
Key |
Type |
Default Value |
Description |
|
|
bool |
true |
Enable/disable run ibdiagnet process |
|
String |
/data |
Directory in which UFM Telemetry data is placed |
|
|
String |
/tmp/ibd |
Directory in which ibdiagnet places files |
|
|
Int |
- |
Frequency of collecting ports counters data |
|
|
String |
mlx5_2 |
Card to use. Can provide a comma-separated list of cards for local high availability |
|
|
bool |
false |
Skip hca state check |
|
|
String |
/opt/collectx/bin/ibdiagnet |
Allow user to specify full path of the ibdiagnet application if necessary |
|
|
String |
discover |
Topology policy |
|
|
Int |
0 |
Every "n" iterations, do discovery, otherwise, use result from last run if 0 or 1 |
|
|
int |
- |
Set the m_key used by ibdiagnet for data collection |
|
|
|
bool |
true |
Enable/disable retention service |
|
time |
1d |
Interval to wait before running the retention process |
|
|
time |
100d |
Period to reserve the collected data |
|
|
|
bool |
true |
Enable/disable compression service |
|
time |
6h |
Interval to wait before running the compression service |
|
|
time |
12h |
Period to reserve the compressed data |
|
|
|
CSV |
- |
weekday/hr:min,hr:hm Time to collect cable info data |
UFM telemetry log file “ibdiagnet2_port_counters.log
” size is monitored by log rotation mechanism. This is highly relevant for cases of long execution time and/or high verbosity, where the number of logs can get excessively big.
To disable log rotation, verify that the following flag is set to 0 (default is 1):
plugin_env_CLX_LOG_ROTATE_ENABLED
To change the number of rotated files, set the following flag (default is 3):
plugin_env_CLX_LOG_ROTATE_NUM_FILES
To change the rotation’s threshold, set the following flag (default is 100M), use [K|M|G] as units:
plugin_env_CLX_LOG_ROTATE_SIZE
There are three optional rotation methods, used in the following order:
rotatelogs - If this executable exists, it will be used for logs rotation, and the rotated files name will differ by index suffix.
logrotate - If this executable exists, it will be used for logs rotation, and the rotated files name will differ by timestamp suffix.
manual rotation - In case both executables are not available, UFM telemetry will manually rotate 2 log files. The older log file will have “
.bck
”
To skip options, the following flag set the executables to use (default is “rotatelogs,logrotate”):
plugin_env_CLX_LOG_ROTATE_APP
The UFM Telemetry auto discovery feature enables in-process topology updates, eliminating the need for process restarts.
This is achieved through additional in-process ad-hoc discoveries and topology updates triggered by external events.
The following parameters configure the auto discovery updates feature:
Key |
Type |
Default Value |
Description |
|
bool |
1 |
Enable auto discovery updates |
|
bool |
0 |
Enable IB Trap triggering from SM |
|
bool |
1 |
Enable triggering from telemetry manager (UTM) |
|
int |
180 |
Minimal interval between 2 consecutive ad-hoc discoveries (Seconds) |
|
bool |
0 |
Enable triggering from clx restart file (when enabled, process will not restart from the file existence) |
|
bool |
0 |
Enable periodic triggering of ad-hoc discoveries |
|
int |
-1 |