Settings and Configuration
Inside the container, the directory /config contains the configuration files for the NVIDIA® UFM® Telemetry application. The file launch_ibdiagnet_config.ini is the main configuration file.
The basic configurations of launch_ibdiagnet_config.ini are listed in the following table.
Section |
Key |
Type |
Default Value |
Description |
ibdiagnet |
ibdiagnet_enabled |
bool |
true |
Enable/disable run ibdiagnet process |
data_dir |
String |
/data |
Directory in which UFM Telemetry data is placed |
|
ibdiag_output_dir |
String |
/tmp/ibd |
Directory in which ibdiagnet places files |
|
sample_rate |
Int |
- |
Frequency of collecting ports counters data |
|
hca |
String |
mlx5_2 |
Card to use |
|
app_name |
String |
/opt/collectx/bin/ibdiagnet |
Allow user to specify full path of the ibdiagnet application if necessary |
|
topology_mode |
String |
discover |
Topology policy |
|
topology_discovery_factor |
Int |
0 |
Every "n" iterations, do discovery, otherwise, use result from last run if 0 or 1 |
|
Retention |
retention_enabled |
bool |
true |
Enable/disable retention service |
retention_interval |
time |
1d |
Interval to wait before running the retention process |
|
retention_age |
time |
100d |
Period to reserve the collected data |
|
compression |
compression_enable |
bool |
true |
Enable/disable compression service |
compression_interval |
time |
6h |
Interval to wait before running the compression service |
|
compression_age |
time |
12h |
Period to reserve the compressed data |
|
cable_info |
cable_info_schedule |
CSV |
- |
weekday/hr:min,hr:hm Time to collect cable info data |
To enable the BER collection, make sure the following lines appear and are not commented out. Specifically, the --enabled_regs dd_ppcnt_plsc needs to be added.
lookup_BER_counters=--get_phy_info --enabled_regs dd_ppcnt_plsc
param_4=BER_counters
Verify that the following flag is commented out or set to 0 (default is 1):
plugin_env_CLX_EXPORT_API_SKIP_PHY_STAT
Comment out the following line to make sure temperature sensing will not be skipped:
# arg_13=--skip temp_sensing
To enable the BER collection, make sure the following lines appear and are not commented out. Specifically, the --enabled_regs dd_ppcnt_plsc needs to be added.
lookup_Grade_counters=--get_phy_info --enabled_regs slrg
param_6=Grade_counters
Verify that the following flag is commented out or set to 0 (default is 1):
plugin_env_CLX_EXPORT_API_SKIP_SLRG