image image image image image

On This Page

Each card is shipped with the latest version of qualified firmware at the time of manufacturing. However, NVIDIA issues firmware updates occasionally that provide new features and bug fixes. To check that your card is programmed with the latest available firmware version, download the mlxup firmware update and query utility. The utility can query for available NVIDIA adapters and indicate which adapters require a firmware update. If the user confirms, mlxup upgrades the firmware using embedded images. The latest mlxup executable and documentation are available in mlxup - Update and Query Utility

Below is an example of a firmware update using the mlxup utility.

[server1]# ./mlxup
Querying Mellanox devices firmware ...
Device Type:     ConnectX-4
Part Number:     MCX453A-FCAT
Description:     ConnectX®-4 VPI adapter card, FDR IB 40/56GbE, single-port QSFP28, PCIe3.0 x8, tall bracket 
PSID:  			 MT_2190110032
PCI Device Name: 0000:06:00.0
Base GUID: 		 e41d2d0300fd8b8a
Versions: 		 Current        Available
FW 				 16.00.0000     16.00.0000

Status: 		 Up to date



Device Type:     ConnectX-4
Part Number:     MCX453A-FCAT
Description:     ConnectX®-4 VPI adapter card, FDR IB 40/56GbE, single-port QSFP28, PCIe3.0 x8, tall bracket 
PSID:  			 MT_2190110032
PCI Device Name: 0000:06:00.0
Base GUID: 		 e41d2d0300fd8b8a
Versions: 		 Current        Available
FW 				 16.00.0000     16.00.1000
Status: 		 Update required

Perform FW update? [y/N]: y
Device #1: Up to date
Device #2: Updating FW ... Done
Restart needed for updates to take effect.
Log File: /var/log/mlxup/mlxup-yyyymmdd.log