Known Issues
The following sections describe known issues in firmware releases and possible workarounds.
| 
     Internal Ref.  | 
                
     Issue  | 
        
| 
     955641  | 
                
     Description: VL_HIGH_LIMIT is not affecting the VL arbiter as expected.  | 
        
| 
     Workaround: Arbitration table should be set using only the low priority VL arbitration table  | 
        |
| 
     Keywords: VL Arbitration  | 
        |
| 
     1249608  | 
                
     Description: Configuring weight “0” for VL, results in unexpected behavior.  | 
        
| 
     Workaround: Arbitration table should be configured with weights other than “0”.  | 
        |
| 
     Keywords: VL Arbitration  | 
        |
| 
     982005  | 
                
     Description: When connecting 6 & 7 meters, link may raise DDR instead of QDR against GD4000/IS5000 switches.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: Link  | 
        |
| 
     -  | 
                
     Description: Congestion Control 1.3 supports congestion log only.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: QoS  | 
        |
| 
     -  | 
                
     Description: VL2VL mode is not supported from an aggregation port to an egress port.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: SHARP  | 
        |
| 
     -  | 
                
     Description: FDR link may rise with symbol errors on optic EDR cable longer than 30M.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: Link  | 
        |
| 
     -  | 
                
     Description: Port LEDs do not flash on system boot.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: LEDs  | 
        |
| 
     -  | 
                
     Description: Link width reduction is not supported in this release.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: Power Management  | 
        |
| 
     -  | 
                
     Description: If QDR is not enabled for the switch's InfiniBand Port Speed while connected to ConnectX-3/Pro or Connect-IB® FDR adapters or to SwitchX® /SwitchX®-2 FDR switches, links will rise at SDR or DDR (even if FDR is enabled).  | 
        
| 
     Workaround: Enable QDR (in addition to FDR) when connecting to peer ports running at FDR  | 
        |
| 
     Keywords: Interoperability  | 
        |
| 
     -  | 
                
     Description: When using NVIDIA AOC cables longer than 50m, use one VL to achieve full wire speed.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: Cables  |