Appendix – Device Management Feature Support
The following table describes the management features available on supported devices.
| Feature | 10 Gb Ethernet Gateway Module | Grid Director 4700/ 4200/ 4036/ 4036E v3.5 | Managed IS5000 Switchesv | Managed SX6000 Switches | Externally Managed IS5000 / SX6000 Switches | Gateway BX5020 | HP C-Class | Linux Hosts | Windows Hosts | 
| Discovery | |||||||||
| IB L2 Discovery | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | 
| Advanced Discovery (IP, hostname, Hosts: CPU, memory, FW version) | Yes | Yes | No | Yes | No | No | No | Yes with UFM Host Agent | No | 
| Ethernet access Management interface | Yes | Yes | Yes | Yes | No | No | No | Yes | Yes | 
| Provisioning/ Configuration | |||||||||
| IB Partitioning (pkey) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | 
| QoS: SL (SM configuration) | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | 
| QoS: Rate Limit (SM configuration) | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | 
| Interface/VIF Configuration (IP, hostname, mtu, Bonding) | N/A | N/A | N/A | N/A | N/A | No | N/A | Yes with UFM Host Agent | No | 
| Device Monitoring | |||||||||
| Device Resources: CPU, Memory, Disk | No | Yes | No | No | No | No | No | Yes with UFM Host Agent | No | 
| Get device alerts (Temperature, PS, Fan) Note: This feature is not supported on Switch-X switches. | Yes | Yes | No | Yes | Yes | No | No | No | No | 
| L1 (Physical Port) –Monitoring | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | 
| L2-3 (Interface/VIF) –Monitoring | No | No | No | No | No | No | No | Yes with UFM Host Agent | No | 
| Congestion Monitoring per port (enables congestion map) | No | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | 
| Congestion Monitoring per flow (Advanced Package) | No | Yes | No | No | No | No | No | No | No | 
| Device Management | |||||||||
| Add/remove to/from Rack | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | 
| Add/remove to/from Logical Server | N/A | N/A | N/A | N/A | N/A | N/A | N/A | Yes | Yes | 
| View/clear Alarms | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | 
| SSH terminal to device | Yes | Yes | Yes | Yes | No | No | No | Yes | Yes | 
| Power On | No | No | No | No | No | No | No | Yes with IPMI | No | 
| Reboot | No | No | No | Yes (SX3606 only) | No | No | No | Yes with IPMI | No | 
| Shutdown | No | No | No | No | No | No | No | Yes with IPMI | No | 
| Port Enable/Disable | No | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | 
| Firmware Upgrade (HCA & switch) | No | Yes | No | Yes (Upon SW upgrade – SX6036 only) | No | No | No | Yes | No | 
| Inband Firmware Upgrade (over InfiniBand connection) | No | No | No | No | Yes | No | No | Yes | Yes | 
| Software Upgrade (OFED & switch) | No | Yes | No | Yes (SX3606 only) | No | No | No | Yes with UFM Host Agent | No | 
| Protocols | |||||||||
| Communication UFM Server – Device | IB/SNMP | IB/UDP /SSH | IB | IB/HTTP/ SSH | IB | IB | IB | IB, SSH, IPMI, UDP | IB | 
- QoS Rate Limit (SM configuration): On ConnectX HCAs-only, for hosts. 
- XmitWait counter monitoring requires ConnectX HCAs with firmware version 2.6 and above. 
- This feature requires that the IP address is configured.