Specifications
ConnectX-6 OCP 3.0 cards were tested for Shock & Vibe in accordance with NVIDIA test procedures, as the OCP spec 3.0 available at that time did not contain any S&V definitions.
A newer version of the OCP spec 3.0 has defined S&V specifications and NVIDIA is in the midst of retesting these cards to comply with OCP spec 3.0.
For more information on NVIDIA Shock & Vibe test procedure, please contact NVIDIA.
Please note that in STBY mode, only port0 is available.
Physical | Size: 4.52in. x 2.99in. (115mm x 76mm) | |||||
Connector: Dual SFP28 Ethernet (copper and optical) | ||||||
Bracket Type: | MCX562A-ACAI: Internal lock bracket | |||||
Protocol Support | Ethernet: 25GBASE-CR/CR-S, 25GBASE-SR, 25GBASE-LR, 25G Ethernet Consortium, 10GBASE-SR, 10GBASE-LR, 10GBASE-ER, SGMII / 1000BASE-X | |||||
Data Rate: 1/10/25 Gb/s Ethernet | ||||||
PCI Express Gen3: SERDES @ 8.0GT/s (respectively), 16 lanes (2.0 and 1.1 compatible) | ||||||
Power and Airflow | Voltage: 3.3V_EDGE, 12V_EDGE | |||||
Active Mode | Standby | |||||
Power | Cable Type | 12V_EDGE | 3.3V_EDGE | |||
Typical Power(a) | Passive Cables | 12.9W | 0.33W | TBD | ||
1.5W Active Cables | 16.35W | 0.33W | TBD | |||
Maximum Power | Passive Cables | 15.3W | 0.33W | TBD | ||
0.75W Active Cables | 18.82W | 0.33W | TBD | |||
Maximum power available through SFP28 port: 1.5W | ||||||
Airflow(d) | Cable Type | Hot Aisle | Cold Aisle @35°C | |||
Active Mode @55°C | Standby Mode @45°C | Active Mode | Standby Mode | |||
Passive Cable | 300LFM | 100LFM | TBD | TBD | ||
Active 1.5W Cable | 400LFM | 100LFM | TBD | TBD | ||
Environmental | Temperature | Operational | 0°C to 55°C | |||
Non-operational | -40°C to 70°C | |||||
Humidity | Operational | 10% to 85% relative humidity | ||||
Non-operational | 10% to 90% relative humidity | |||||
Altitude (Operational) | 3050m | |||||
Regulatory | Safety | CB / cTUVus / CE | ||||
EMC | CE / FCC / VCCI / ICES / RCM | |||||
RoHS | RoHS compliant |
a. Typical power for ATIS traffic load.
b. For both operational and non-operational states.
Physical | Size: 4.52in. x 2.99in. (115mm x 76mm) | |||||
Connector: Dual QSFP28 Ethernet (copper and optical) | ||||||
Bracket: Internal lock bracket | ||||||
Protocol Support | Ethernet: 100GBASE-CR4, 100GBASE-KR4, 100GBASE-SR4, 50GBASE-R2, 50GBASE-R4, 40GBASE-CR4, 40GBASE-KR4, 40GBASE-SR4, 40GBASE-LR4, 40GBASE-ER4, 40GBASE-R2, 25GBASE-R, 20GBASE-KR2, 10GBASE-LR,10GBASE-ER, 10GBASE-CX4, 10GBASE-CR, 10GBASE-KR, SGMII, 1000BASE-CX, 1000BASE-KX, 10GBASE-SR | |||||
Data Rate: 1/10/25/40/50/100 Gb/s Ethernet | ||||||
PCI Express Gen3.0: SERDES @ 8.0GT/s x16 lanes (2.0 and 1.1 compatible Warning
PCIe 3.0 x16 bus can supply a maximum bandwidth of 128Gb/s only (=16 * 8GT/s, including overhead), and therefore cannot support 200Gb/s when both network ports of MCX556A-ECAT run at 100Gb/s. | ||||||
Power and Airflow | Voltage: 3.3V_EDGE, 12V_EDGE | |||||
Power | Cable Type | Active Mode | Standby Mode | |||
12V_EDGE | 3.3V_EDGE | |||||
Typical Power(a) | Passive Cables | 16.5W | 0.33W | TBD | ||
2.2W Active Cables | 21.7W | 0.33W | TBD | |||
Maximum Power | Passive Cables | 19.3W | 0.33W | TBD | ||
2.2W Active Cables | 24.5W | 0.33W | TBD | |||
Maximum power available through QSFP28 port: 2.2W | ||||||
Airflow | Cable Type | Hot Aisle @55C | Cold Aisle @35C | |||
Active Mode @55C | Standby Mode @45C | Active Mode | Standby Mode | |||
Passive Cable | 300LFM | 100LFM | NA | NA | ||
Active 2.2W Cable (85°C cage limit) | 300LFM | 100LFM | NA | NA | ||
Environmental | Temperature | Operational | 0°C to 55°C | |||
Non-operational | -40°C to 70°C | |||||
Humidity | Operational | 10% to 85% relative humidity | ||||
Non-operational | 10% to 90% relative humidity | |||||
Altitude (Operational) | 3050m | |||||
Regulatory | Safety | CB / cTUVus / CE | ||||
EMC | CE / FCC / VCCI / ICES / RCM | |||||
RoHS | RoHS compliant |
a. Typical power for ATIS traffic load.
b. For both operational and non-operational states.
Physical | Size: 4.52in. x 2.99in. (115mm x 76mm) | |||||
Connector: Single QSFP28 Ethernet (copper and optical) | ||||||
Bracket: Thumbscrew (Pull Tab) bracket | ||||||
Protocol Support | Ethernet: 100GBASE-CR4, 100GBASE-KR4, 100GBASE-SR4, 50GBASE-R2, 50GBASE-R4, 40GBASE-CR4, 40GBASE-KR4, 40GBASE-SR4, 40GBASE-LR4, 40GBASE-ER4, 40GBASE-R2, 25GBASE-R, 20GBASE-KR2, 10GBASE-LR,10GBASE-ER, 10GBASE-CX4, 10GBASE-CR, 10GBASE-KR, SGMII, 1000BASE-CX, 1000BASE-KX, 10GBASE-SR | |||||
Data Rate: 1/10/25/40/50/100 Gb/s Ethernet | ||||||
PCI Express Gen3.0: SERDES @ 8.0GT/s x16 lanes (2.0 and 1.1 compatible | ||||||
Power and Airflow | Voltage: 3.3V_EDGE, 12V_EDGE | |||||
Power | Cable Type | Active Mode | Standby Mode | |||
12V_EDGE | 3.3V_EDGE | |||||
Typical Power(a) | Passive Cables | 14.5W | 0.33W | TBD | ||
2.2W Active Cables | 17W | 0.33W | TBD | |||
Maximum Power | Passive Cables | 17.2W | 0.33W | TBD | ||
2.2W Active Cables | 19.8W | 0.33W | TBD | |||
Maximum power available through QSFP28 port: 2.2W | ||||||
Airflow | Cable Type | Hot Aisle @55C HSK to Port | Cold Aisle @35C Port to HSK | |||
Active Mode @55C | Standby Mode @45C | Active Mode | Standby Mode | |||
Passive Cable | 250LFM | 100LFM | 200LFM | 100LFM | ||
Active 2.2W Cable (85°C cage limit) | 250LFM | 100LFM | 200LFM | 100LFM | ||
Environmental | Temperature | Operational | 0°C to 55°C | |||
Non-operational | -40°C to 70°C | |||||
Humidity | Operational | 10% to 85% relative humidity | ||||
Non-operational | 10% to 90% relative humidity | |||||
Altitude (Operational) | 3050m | |||||
Regulatory | Safety | CB / cTUVus / CE | ||||
EMC | CE / FCC / VCCI / ICES / RCM | |||||
RoHS | RoHS compliant |
a. Typical power for ATIS traffic load.b. For both operational and non-operational states.
Physical | Size: 4.52in. x 2.99in. (115mm x 76mm) | |||||
Connector: Dual QSFP28 Ethernet (copper and optical) | ||||||
Bracket type: | MCX566A-CDAB: Thumbscrew (Pull-Tab) bracket | |||||
Protocol Support | Ethernet: 100GBASE-CR4, 100GBASE-KR4, 100GBASE-SR4, 50GBASE-R2, 50GBASE-R4, 40GBASE-CR4, 40GBASE-KR4, 40GBASE-SR4, 40GBASE-LR4, 40GBASE-ER4, 40GBASE-R2, 25GBASE-R, 20GBASE-KR2, 10GBASE-LR,10GBASE-ER, 10GBASE-CX4, 10GBASE-CR, 10GBASE-KR, SGMII, 1000BASE-CX, 1000BASE-KX, 10GBASE-SR | |||||
Data Rate: 1/10/25/40/50/100 Gb/s Ethernet | ||||||
PCI Express Gen3.0/4.0: SERDES @ 8.0GT/s /16.0GT/s, x16 lanes (2.0 and 1.1 compatible Warning
PCIe 4.0 x16 bus can supply a maximum bandwidth of 256Gb/s (=16 * 16GT/s, including overhead), and therefore is able to support 200Gb/s when both network ports run at 100Gb/s | ||||||
Power and Airflow | Voltage: 3.3V_EDGE, 12V_EDGE | |||||
Power | Cable Type | Active Mode | Standby Mode | |||
12V_EDGE | 3.3V_EDGE | |||||
Typical Power(a) | Passive Cables | 19.65W | 0.33W | TBD | ||
2.2W Active Cables | 24.8W | 0.33W | TBD | |||
Maximum Power | Passive Cables | 23.9W | 0.33W | TBD | ||
2.2W Active Cables | 29.0W | 0.33W | TBD | |||
Maximum power available through QSFP28 port: 2.2W | ||||||
Airflow | Cable Type | Hot Aisle @55C | Cold Aisle @35C | |||
Active Mode @55C | Standby Mode @45C | Active Mode | Standby Mode | |||
Passive Cable | 500LFM | 100LFM | NA | NA | ||
Active 2.2W Cable (85°C cage limit) | 500LFM | 100LFM | NA | NA | ||
Environmental | Temperature | Operational | 0°C to 55°C | |||
Non-operational | -40°C to 70°C | |||||
Humidity | Operational | 10% to 85% relative humidity | ||||
Non-operational | 10% to 90% relative humidity | |||||
Altitude (Operational) | 3050m | |||||
Regulatory | Safety | CB / cTUVus / CE | ||||
EMC | CE / FCC / VCCI / ICES / RCM | |||||
RoHS | RoHS compliant |
a. Typical power for ATIS traffic load.
b. For both operational and non-operational states.
Physical | Size: 4.52in. x 2.99in. (115mm x 76mm) | |||||
Connector: Single QSFP28 Ethernet (copper and optical) | ||||||
Bracket type: | ||||||
Protocol Support | Ethernet: 100GBASE-CR4, 100GBASE-KR4, 100GBASE-SR4, 50GBASE-R2, 50GBASE-R4, 40GBASE-CR4, 40GBASE-KR4, 40GBASE-SR4, 40GBASE-LR4, 40GBASE-ER4, 40GBASE-R2, 25GBASE-R, 20GBASE-KR2, 10GBASE-LR,10GBASE-ER, 10GBASE-CX4, 10GBASE-CR, 10GBASE-KR, SGMII, 1000BASE-CX, 1000BASE-KX, 10GBASE-SR | |||||
Data Rate: 1/10/25/40/50/100 Gb/s Ethernet | ||||||
PCI Express Gen3.0/4.0: SERDES @ 8.0GT/s /16.0GT/s, x16 lanes (2.0 and 1.1 compatible | ||||||
Power and AIrflow | Voltage: 3.3V_EDGE, 12V_EDGE | |||||
|
| Active Mode | Standby Mode | |||
12V_EDGE | 3.3V_EDGE | |||||
Typical Power(a) | Passive Cables | 19W | 0.33W | TBD | ||
2.2W Active Cables | 21.5W | 0.33W | TBD | |||
Maximum Power | Passive Cables | 23W | 0.33W | TBD | ||
2.2W Active Cables | 25.6W | 0.33W | TBD | |||
Maximum power available through QSFP28 port: 2.2W | ||||||
Airflow | Cable Type | Hot Aisle @55C | Cold Aisle @35C | |||
Active Mode @55C | Standby Mode @45C | Active Mode | Standby Mode | |||
Passive Cable | 500LFM | 100LFM | 300LFM | 100LFM | ||
Active 2.2W Cable (85°C cage limit) | 500LFM | 100LFM | 300LFM | 100LFM | ||
Environmental | Temperature | Operational | 0°C to 55°C | |||
Non-operational | -40°C to 70°C | |||||
Humidity | Operational | 10% to 85% relative humidity | ||||
Non-operational | 10% to 90% relative humidity | |||||
Altitude (Operational) | 3050m | |||||
Regulatory | Safety | CB / cTUVus / CE | ||||
EMC | CE / FCC / VCCI / ICES / RCM | |||||
RoHS | RoHS compliant |
a. Typical power for ATIS traffic load.
b. For both operational and non-operational states.
All dimensions are in millimeters. All the mechanical tolerances are +/- 0.1mm.
MCX562A-ACAI Drawings | MCX562A-ACAB Drawings |
MCX566A-CCAI Drawings | MCX566A-CDAB Drawings |
MCX566A-CDAI Drawings | MCX565M-CDAI/MCX565M-CDAB Drawings |
All dimensions are in millimeters. All the mechanical tolerances are +/- 0.1mm.
MCX562A-ACAI Bracket | MCX562A-ACAB Bracket |
MCX566A-CCAI / MCX566M-GDAI / MCX566A-CDAI Bracket | MCX565A-CCAB / MCX565M-CDAB Bracket |
MCX565M-CDAI Bracket | MCX566A-CDAB Bracket |