Known Issues
VF Network Function Limitations in SR-IOV Legacy Mode
| 
     Dual Port Device  | 
                
     Single Port Device  | 
        
| 
     127 VF per PF (254 functions)  | 
                
     127  | 
        
VF Network Function Limitations in Switchdev Mode
| 
     Dual Port Device  | 
                
     Single Port Device  | 
        
| 
     127 VF per PF (254 functions)  | 
                
     127  | 
        
VF+SF Network Function Limitations in Switchdev Mode
| 
     Dual Port Device  | 
                
     Single Port Device  | 
        
    
  | 
                
    
  | 
        
| 
     Internal Ref.  | 
                
     Issue  | 
        
| 
     3795140  | 
                
     Description: Firmware cannot reach the line rate with a single QP while running traffic.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: Line rate, MCX750500B-0D0K / MCX750500B-0D00  | 
        |
| 
     Discovered in Version: 28.39.3004  | 
        |
| 
     3649572  | 
                
     Description: Downgrading from firmware version 28.39.2048 to a lower one requires performing a Power Cycle after firmware burning and not fwreset.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: Firmware downgrade, power cycle  | 
        |
| 
     Discovered in Version: 28.39.1002  | 
        |
| 
     3614362  | 
                
     Description: When connected to a Spectrum-1 switch system using NRZ 25G optic module supporting DME in NO FEC, an EFF BER of -13 may be seen once in 200 toggles.  | 
        
| 
     Workaround: To raise the link, re-toggle the port.  | 
        |
| 
     Keywords: Spectrum-1, NRZ, BER, port toggling  | 
        |
| 
     Discovered in Version: 28.39.1002  | 
        |
| 
     3629216  | 
                
     Description: mlxfwreset level 3 command is not supported for MCX750500B-0D00 / MCX750500B-0D0K / MCX755206AS-NEAT-N P/N.  | 
        
| 
     Workaround: 
  | 
        |
| 
     Keywords: mlxfwreset level 3  | 
        |
| 
     Discovered in Version: 28.39.1002  | 
        |
| 
     -  | 
                
     Description: The I2C clock fall time is lower than the 12ns minimum defined in the I2C-bus specification. For further information, refer to the I²C-bus Specification, Version 7.0, October 2021, https://www.i2c-bus.org/.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: I2C clock  | 
        |
| 
     Discovered in Version: 28.39.1002  | 
        |
| 
     3179534  | 
                
     Description: 25G/lane speeds are not supported on 200GbE optic cables.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: Cables, 200GbE  | 
        |
| 
     Discovered in Version: 28.39.1002  | 
        |
| 
     3606136  | 
                
     Description: In rare cases, linkup time of NDR and NDR200 with MMA4Z00-NS400 may take longer than 60 seconds.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: Cables, NDR, NDR200, linkup time  | 
        |
| 
     Discovered in Version: 28.39.1002  | 
        |
| 
     3435259  | 
                
     Description: The host enables the device to populate only 1 bus. When opening extra 2 Physical ports, moving from dual-port to quad-port, the user can open 2 less Virtual Functions.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: VF, dual-port, quad-port  | 
        |
| 
     Discovered in Version: 28.39.1002  | 
        |
| 
     3525865  | 
                
     Description: Unexpected system behavior might be observed if the driver is loaded while reset is in progress.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: Sync 1 reset, firmware reset  | 
        |
| 
     Discovered in Version: 28.39.1002  | 
        |
| 
     3363753  | 
                
     Description: The link is down when connected to the MMS1V00-WM (DR4) optical module.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: 400G, link down  | 
        |
| 
     Discovered in Version: 28.38.1002  | 
        |
| 
     3439438  | 
                
     Description: When connecting to a High Speed Traffic Generator in 400G speed, the linkup time may takes up to 3 minutes.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: 400G, linkup time  | 
        |
| 
     Discovered in Version: 28.38.1002  | 
        |
| 
     3457472  | 
                
     Description: Disabling the Relaxed Ordered (RO) capability (relaxed_ordering_read_pci_enabled=0) using the vhca_resource_manager is currently not functional.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: Relaxed Ordered  | 
        |
| 
     Discovered in Version: 28.37.1014  | 
        |
| 
     3275394  | 
                
     Description: When performing PCIe link secondary-bus-reset, disable/enable or mlxfwreset on AMD based Genoa systems, the device takes longer then expected to link up, due to a PCIe receiver termination misconfiguration.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: PCIe  | 
        |
| 
     Discovered in Version: 28.37.1014  | 
        |
| 
     -  | 
                
     Description: When upgrading from firmware v28.35.2000 to a newer one, the default port speeds of adapter cards MCX755106AS-HEAT/ MCX755106AC-HEAT will change from InfiniBand to Ethernet.  | 
        
| 
     Workaround: To change it back to InfiniBand, please follow the instructions in the ConnectX-7 hardware User Manual.  | 
        |
| 
     Keywords: Firmware upgrade, port type, MCX755106AS-HEAT/ MCX755106AC-HEAT  | 
        |
| 
     Discovered in Version: 28.37.1014  | 
        |
| 
     3376224  | 
                
     Description: FEC override is not supported when working with NRZ speeds on PAM4 Optical modules.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: FEC override, NRZ, PAM4  | 
        |
| 
     Discovered in Version: 28.37.1014  | 
        |
| 
     3262845  | 
                
     Description: In the ConnectX-7 adapter card with P/N MCX750500B-0D0K, t he "Fatal Error Reporting Enable" bit controls both the fatal and the non-fatal ERR MSG forwarding. The "Non-Fatal Error Reporting Enable" bit does not affect the ERR MSG forwarding.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: Fatal Error Reporting Enable" bit, PCIe, MCX750500B-0D0K  | 
        |
| 
     Discovered in Version: 28.36.1010  | 
        |
| 
     3312483  | 
                
     Description: WoL packets may not working properly if sent to Unicast destination MAC.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: WoL packets, Unicast destination MAC  | 
        |
| 
     Discovered in Version: 28.36.1010  | 
        |
| 
     3339919  | 
                
     Description: 
  | 
        
| 
     Workaround: To raise in Force flow, configure the speed, FEC and precoding.  | 
        |
| 
     Keywords: Link up speed  | 
        |
| 
     Discovered in Version: 28.36.1010  | 
        |
| 
     3339818  | 
                
     Description: When performing a stress toggling on a ConnectX-7 adapter card that is connected to the MMA1Z00-NS400 cable and the speed is set to 100G_1x with interleaved FEC, a long linkup time of up to 5 min may occur.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: Toggling, MMA1Z00-NS400  | 
        |
| 
     Discovered in Version: 28.36.1010  | 
        |
| 
     3329109  | 
                
     Description: MFS1S50-H003E cable supports only HDR rate when used as a split cable.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: HDR, split cable, MFS1S50-H003E  | 
        |
| 
     Discovered in Version: 28.36.1010  | 
        |
| 
     2844036  | 
                
     Description: When using the "Dual Write" feature with QP buffer bigger than the maximum outstanding WQEs (128), the data being sent on the standby QP can be corrupted.  | 
        
| 
     Workaround: Limit the QP buffer size when using "Dual Write" up to 128 WQEs.  | 
        |
| 
     Keywords: Dual-write, QP  | 
        |
| 
     Discovered in Version: 28.36.1010  | 
        |
| 
     3178339  | 
                
     Description: PCIe PML1 is disabled.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: PCIe PML1  | 
        |
| 
     Discovered in Version: 28.35.1012  | 
        |
| 
     3110297  | 
                
     Description: When ConnectX-7 adapter card is configured to use the Auto-Negotiation mode, 400G_8x linkup cannot be raised.  | 
        
| 
     Workaround: Configure the adapter card to use Force mode.  | 
        |
| 
     Keywords: 400G_8x, linkup  | 
        |
| 
     Discovered in Version: 28.34.4000  | 
        |
| 
     3033910  | 
                
     Description: BAR misses caused by a memory write/read actions are not reported in the AER and the device status.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: BAR miss, AER  | 
        |
| 
     Discovered in Version: 28.34.4000  | 
        |
| 
     3140645  | 
                
     Description: 3rd party servers may hang after warm reboot due to the PCIe switch.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: PCIe, 3rd party servers  | 
        |
| 
     Discovered in Version: 28.34.4000  | 
        |
| 
     -  | 
                
     Description: Changing dynamic PCIe link width is not supported.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: PCIe  | 
        |
| 
     Discovered in Version: 28.34.1002  | 
        |
| 
     3174038  | 
                
     Description: SPDM requests received while CPLD burn flow is in progress may be answered with incorrect responses.  | 
        
| 
     Workaround: Avoid activation of the two flows in tandem.  | 
        |
| 
     Keywords: SPDM  | 
        |
| 
     Discovered in Version: 28.34.1002  | 
        |
| 
     3141072  | 
                
     Description: The "max_shaper_rate" configuration query via QEEC mlxreg returns a value translated to hardware granularity.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: RX Rate-Limiter, Multi-host  | 
        |
| 
     Discovered in Version: 28.34.1002  | 
        |
| 
     2870970  | 
                
     Description: GTP encapsulation (flex parser profile 3) is limited to the NIC domain. Encapsulating in the FDB domain will render a 0-size length in GTP header.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: GTP encapsulation  | 
        |
| 
     Discovered in Version: 28.34.1002  | 
        |
| 
     3081264  | 
                
     Description: 10G/40G speeds are not supported on MFS1S00-XXXX modules (200G optics) in ConnectX-7 adapter cards.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: Optical cables  | 
        |
| 
     Discovered in Version: 28.33.4030  | 
        |
| 
     3070590  | 
                
     Description: PLL modules are not supported in ConnectX-7 ethernet adapter cards.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: PLL  | 
        |
| 
     Discovered in Version: 28.33.4030  | 
        |
| 
     3070409  | 
                
     Description: When connecting a ConnectX-7 adapter card to a ConnectX-6 Dx or an NVIDIA Spectrum-3 switch, NRZ speeds are not raised when using 200GbE optical cable.  | 
        
| 
     Workaround: Configure PHY_FEC_OVERRIDE on the ConnectX-7 side for the requested speed.  | 
        |
| 
     Keywords: Optical cables, NRZ, ConnectX-6 Dx, NVIDIA Spectrum-3, 200GbE optical cable  | 
        |
| 
     Discovered in Version: 28.33.4030  | 
        |
| 
     2993531  | 
                
     Description: PML1 is disabled by default. Enabling it might result in server hanging.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: PML1  | 
        |
| 
     Discovered in Version: 28.33.2028  | 
        |
| 
     -  | 
                
     Description: Upgrading to firmware 28.33.2028 from any previous Engineering Sample (earlier than version 28.98.2406) must be done before installing WinOF-2 v2.90 driver and requires going through the following steps: 
  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: Firmware upgrade  | 
        |
| 
     Discovered in Version: 28.33.2028  | 
        |
| 
     -  | 
                
     Description: Downgrading from firmware 28.33.2028 to any previous Engineering Sample firmware is not supported.  | 
        
| 
     Workaround: N/A  | 
        |
| 
     Keywords: Firmware downgrade  | 
        |
| 
     Discovered in Version: 28.33.2028  |