Known Issues History
Ref # | Issue | ||
Rev 6.20.0 / 6.20.1 | |||
4261896 | Description: XDR optical cable transceivers (Wolvarine) information is not exposed in UFM (for both REST API and Web UI) | ||
Keywords: Cable, Transceiver, Info, Wolvarine | |||
Workaround: N/A | |||
Discovered in Release: 6.20.0 | |||
4289083 | Description: ibdiagnet, a diagnostic tool for InfiniBand networks, fails to discover unmanaged switches when a specific VS key is enabled, resulting in incomplete network discovery. | ||
Keywords: ibdiagnet, Unmanaged Switches, VS key | |||
Workaround: N/A | |||
Discovered in Release: 6.20.0 | |||
4221551 | Description: Removed the " | ||
Keywords: Plugin, Upgrade, | |||
Workaround: For upgrading UFM plugins, please refer to the instruction provided in UFM Plugin Upgrade Procedure. | |||
Discovered in Release: 6.20.0 | |||
Rev 6.19.6 | |||
4224081 | Description: Burning of XDR cables using XDR switch is not supported. | ||
Keywords: XDR, Cables, Switch | |||
Workaround: N/A | |||
Discovered in Release: 6.19.6 | |||
3397981 | Description: Showing extended cable information for aggregated XDR switch port is not supported by UFM. | ||
Keywords: XDR, Cable Information, Switch | |||
Workaround: N/A | |||
Discovered in Release: 6.19.6 | |||
Rev 6.19.0 | |||
4119214 | Description: In case of pulling telemetry data from the UFM server (High or low-frequency instances), the loopback/local host IP should be used instead of the hostname or host IP. Example of High-Frequency (Primary) Telemetry Instance:
Example of Low-Frequency (Secondary) Telemetry Instance:
| ||
Keywords: Localloop IP, Telemetry, Local Host | |||
Workaround: N/A | |||
Discovered in Release: 6.19.0 | |||
4151847 | Description: Primary Telemetry is not updated properly | ||
Keywords: Primary Telemetry | |||
Workaround: Comment out or remove the line that defines If UFM is already running, restart the telemetry service for the change to take effect by running | |||
Discovered in Release: 6.19.0 | |||
4157855 | Description: The High-Frequency (Primary) Telemetry instance is missing the necessary environment variable in UTM (non-legacy) mode, which causes an incorrect sample rate.
| ||
Keywords: Telemetry | |||
Workaround:
| |||
Discovered in Release: 6.19.0 | |||
4172677 | Description: UFM Telemetry server experiencing slowdowns in data collection and response to requests | ||
Keywords: Telemetry, Slowdown, Data Collection | |||
Workaround: Implement the following configuration update on both the primary and secondary telemetry:
Then, restart UFM or UFM Telemetry. | |||
Discovered in Release: 6.19.0 | |||
4161921 | Description: VL15 counters are returned NA due to invalid parsing of the response. | ||
Keywords: L15 counters, Management Traffic, ibdiagnet | |||
Workaround: N/A | |||
Discovered in Release: 6.19.0 | |||
Rev 6.18.0 | |||
3991199 | Description: Dynamic Telemetry instances are not recovered during the backup/restore procedure | ||
Keywords: Dynamic Telemetry, Backup, Restore | |||
Workaround: N/A | |||
Discovered in Release: 6.17.5 | |||
Rev 6.17.0 | |||
3859362 | Description: UFM TFS endpoint dashboard report Switch port TX/RX rate reach Tbps | ||
Keywords: TFS, Switch Port, TX/RX | |||
Workaround: N/A | |||
Discovered in Release: v6.15.1 | |||
3881365 | Description: Malfunctioning of the rest API when deleting port associated to a pkey | ||
Keywords: CloudX, API, Bare-Metal | |||
Workaround: N/A | |||
Discovered in Release: v6.15.2 | |||
3862847 | Description: UFM reports wrong cable length for NDR optical cables connected to Quantum-2 NDR switch | ||
Keywords: NDR, Optical Cables, Quantum-2, Switch | |||
Workaround: N/A | |||
Discovered in Release: v6.17.0 |