Prerequisites and Features

View as Markdown

Prerequisites and features are additional infrastructure required by a tenant’s NVIDIA Run:ai cluster. Prerequisites are components every tenant cluster depends on, such as the GPU Operator. Features extend NVIDIA Run:ai to support specific workload types, such as distributed training or inference, and only need to be installed for the workloads that tenant plans to run. This page describes how to install them manually using Helm, along with any Helm-specific handling. For detailed version compatibility, refer to the Support Matrix.

ComponentTypeRequired for
GPU OperatorPrerequisiteEvery tenant cluster
Network OperatorPrerequisiteRDMA or Multi-Node NVLink (MNNVL)-capable nodes
DRA DriverPrerequisiteMulti-Node NVLink (e.g. GB200)
PrometheusPrerequisiteEvery tenant cluster
Kubeflow Training OperatorFeatureDistributed training
MPI OperatorFeatureMPI-based distributed training
Knative ServingFeatureStandard (single-node) inference
LeaderWorkerSet (LWS)FeatureDistributed (multi-node) inference
NIM OperatorFeatureNVIDIA Inference Microservices
GroveFeatureMulti-component, gang-scheduled workload orchestration (for example, disaggregated Dynamo deployments)
DynamoFeatureInference pipeline optimization

Before You Start

Complete Preparations before starting here. The operators and frameworks described on this page must be installed before you create the tenant and cluster, on that tenant’s own Kubernetes cluster.

Prerequisites

NVIDIA GPU Operator

The NVIDIA GPU Operator provisions and manages GPUs on worker nodes, and is required for a tenant cluster to run AI workloads.

Note

For Multi-Node NVLink support (e.g. GB200), GPU Operator 25.3 and above is required.

Note

To use GPU fractions (memory fractions, dynamic memory fractions, or compute modes), the following are required:

  • GPU Operator 26.7.1 or later is required.
  • CUDA driver r615 or later is required. GPU Operator 26.7.1 does not default to it, so set the driver version explicitly rather than relying on the default - with --set driver.version=<version> on Kubernetes, or by setting driver.version in the ClusterPolicy spec on OpenShift, where the GPU Operator is installed from OperatorHub.
  • The NRI plugin must be disabled. Install the GPU Operator with cdi.nriPluginEnabled set to false (--set cdi.nriPluginEnabled=false on Kubernetes, or cdi.nriPluginEnabled: false in the ClusterPolicy spec on OpenShift). GPU memory fractions do not function while the NRI plugin is enabled.

See GPU Memory Fractions for the full requirement set.

  • For installation instructions, see Installing the NVIDIA GPU Operator.
  • Use the default gpu-operator namespace. Otherwise, you must specify the target namespace using the flag clusterConfig.global.nvidiaDcgmExporter.namespace as described in Advanced Cluster Configurations.
  • NVIDIA drivers may already be installed on the nodes. In such cases, use the NVIDIA GPU Operator flags --set driver.enabled=false. DGX OS is one such example as it comes bundled with NVIDIA Drivers.
  • For distribution-specific requirements and additional instructions, see the sections below:

OpenShift Container Platform (OCP)

The Node Feature Discovery (NFD) Operator is a prerequisite for the NVIDIA GPU Operator in OpenShift. Install the NFD Operator using the Red Hat OperatorHub catalog in the OpenShift Container Platform web console. For more information, see Installing the Node Feature Discovery (NFD) Operator.

Rancher Kubernetes Engine 2 (RKE2)

Before installing the GPU Operator, verify the host OS requirements are met. Then, install the operator.

When installing GPU Operator v25.3, update the Helm values file as follows:

apiVersion: helm.cattle.io/v1
kind: HelmChart
metadata:
name: gpu-operator
namespace: kube-system
spec:
repo: https://helm.ngc.nvidia.com/nvidia
chart: gpu-operator
version: v25.3.4
targetNamespace: gpu-operator
createNamespace: true
valuesContent: |-
toolkit:
env:
- name: CONTAINERD_SOCKET
value: /run/k3s/containerd/containerd.sock

For troubleshooting information, see the NVIDIA GPU Operator Troubleshooting Guide.

NVIDIA Network Operator

When deploying on clusters with RDMA or Multi-Node NVLink-capable nodes (for example B200, GB200), the NVIDIA Network Operator is required to enable high-performance networking features such as GPUDirect RDMA in Kubernetes.

The Network Operator works alongside the NVIDIA GPU Operator to provide:

  • NVIDIA networking drivers for advanced network capabilities.
  • Kubernetes device plugins to expose high-speed network hardware to workloads.
  • Secondary network components to support network-intensive applications.

The Network Operator must be installed and configured as follows:

  1. Install the network operator as detailed in Network Operator Deployment on Vanilla Kubernetes Cluster.
  2. Configure SR-IOV InfiniBand support as detailed in Network Operator Deployment with an SR-IOV InfiniBand Network.

NVIDIA Dynamic Resource Allocation (DRA) Driver

When deploying on clusters with Multi-Node NVLink (e.g. GB200), the NVIDIA DRA driver is required.

How the DRA driver is installed depends on the GPU Operator mode. A cluster runs in one mode only:

  • ClusterPolicy mode (default) - GPUs are exposed through the NVIDIA device plugin. Install the DRA driver separately. Refer to Support Matrix for the supported DRA driver versions.
  • GPUCluster mode (GPU Operator 26.7, new installations only) - The GPU Operator deploys the DRA driver, which replaces the device plugin.

For details, refer to NVIDIA DRA driver and, on OpenShift, Installing the NVIDIA GPU Operator with DRA on OpenShift.

Important

NVIDIA Run:ai limitations in GPUCluster mode:

After the DRA driver is installed, update the cluster configuration using the anyworkload-controller.GPUNetworkAccelerationEnabled flag to enable GPU network acceleration. This triggers an update of the NVIDIA Run:ai anyworkload-controller deployment and restarts the controller. For details on how to configure this value using Helm or runaiconfig, see Advanced Cluster Configurations.

Prometheus

Note

Installing Prometheus applies to Kubernetes only.

NVIDIA Run:ai requires Prometheus on the tenant’s Kubernetes cluster. The setup has two parts:

  • Prerequisite: Kube-Prometheus Stack. On Kubernetes, install the Kube-Prometheus Stack to provide the Prometheus Operator and the Prometheus Custom Resource Definitions (CRDs). OpenShift includes equivalent components through its built-in Cluster Monitoring Operator, so no install is required.
  • NVIDIA Run:ai Prometheus instance. During cluster installation, the NVIDIA Run:ai cluster operator creates a dedicated Prometheus Custom Resource (CR) in the runai namespace. This step applies to both Kubernetes and OpenShift, and produces the Prometheus instance that NVIDIA Run:ai uses for monitoring.

For RKE2, see Enable Monitoring for instructions on installing Prometheus.

The following example installs the community Kube-Prometheus Stack using helm:

helm repo add prometheus-community https://prometheus-community.github.io/helm-charts
helm repo update
helm install prometheus prometheus-community/kube-prometheus-stack \
-n monitoring --create-namespace --set grafana.enabled=false

Features

To enable NVIDIA Run:ai capabilities such as Distributed Training and Inference, additional Kubernetes applications (frameworks) must be installed on the tenant’s cluster. Only install what that tenant needs for the workload types it plans to run.

Distributed Training

NVIDIA Run:ai supports distributed training - training AI models across multiple nodes - using the Kubeflow Training Operator for TensorFlow, PyTorch, XGBoost, and JAX workloads, and the MPI Operator for MPI v2-based workloads. Both are required for compatibility with advanced workload capabilities such as stopping a workload and scheduling rules.

It is recommended to use Kubeflow Training Operator v1.9.2, and MPI Operator v0.6.0 or later.

  • To install the Kubeflow Training Operator for TensorFlow, PyTorch, XGBoost and JAX frameworks, run the following command:

    kubectl apply --server-side -k "github.com/kubeflow/training-operator.git/manifests/overlays/standalone?ref=v1.9.2"
  • To install the MPI Operator for MPI v2, run the following command:

    kubectl apply --server-side -f https://raw.githubusercontent.com/kubeflow/mpi-operator/v0.6.0/deploy/v2beta1/mpi-operator.yaml

Note

If you require both the MPI Operator and Kubeflow Training Operator, follow the steps below:

  • Install the Kubeflow Training Operator as described above.

  • Disable and delete MPI v1 in the Kubeflow Training Operator by running:

    kubectl patch deployment training-operator -n kubeflow --type='json' -p='[{"op": "add", "path": "/spec/template/spec/containers/0/args", "value": ["--enable-scheme=tfjob", "--enable-scheme=pytorchjob", "--enable-scheme=xgboostjob", "--enable-scheme=jaxjob"]}]'
    kubectl delete crd mpijobs.kubeflow.org
  • Install the MPI Operator as described above.

Standard Inference

NVIDIA Run:ai uses Knative Serving to enable standard (single-node) inference. Knative Serving lets a tenant serve AI models as production workloads, using NVIDIA NIM, vLLM, or custom inference servers. It provides serverless, dynamic autoscaling (including scale to zero when idle), rolling updates without disrupting served traffic, and endpoints reachable via external access (a wildcard FQDN) or internal, cluster-local access. Supports Knative versions 1.19 to 1.21.

Note

On OpenShift, Knative is installed through the OpenShift Serverless operator, which supports Knative 1.17 only.

To configure inference:

  • Inference request metrics (OTLP) - For Knative Serving 1.19 or later, add the observability block to your KnativeServing YAML to export request metrics to the NVIDIA Run:ai API and UI. See Inference Request Metrics (OTLP) below.
  • Internal or external access - Choose how inference services are reached: externally via a wildcard FQDN (the default) or cluster-local. See the matching section below.

Inference Request Metrics (OTLP)

To surface inference request metrics in the NVIDIA Run:ai API and UI, configure Knative Serving 1.19 or later to export request metrics over OpenTelemetry Protocol (OTLP) to the NVIDIA Run:ai Prometheus instance. The observability block included in the KnativeServing YAML examples below sets the required config-observability keys (metrics-protocol, request-metrics-protocol, request-metrics-endpoint). For supported fields, see Enabling metric collection in the Knative documentation.

The OTLP receiver on the NVIDIA Run:ai Prometheus instance is enabled by default.

To disable it, set spec.prometheus.config.enableOTLPReceiver: false. See Advanced Cluster Configurations for more details.

External-Access Inference

With external access, inference services are reachable from outside the cluster. Use this mode when inference workloads must be reachable by clients outside the cluster.

On Kubernetes, external access exposes inference services through a wildcard FQDN (for example, *.runai-inference.tenant-a-corp.com). This requires the wildcard DNS record (see FQDN and DNS), the standard inference wildcard certificate (see Preparations), and an HAProxy ingress to handle TLS termination.

Follow the Installing Knative instructions or run:

helm repo add knative-operator https://knative.github.io/operator
helm install knative-operator --create-namespace --namespace knativeoperator --version 1.18.2 knative-operator/knative-operator

Once installed, follow the below steps:

  1. Create the knative-serving namespace:

    kubectl create ns knative-serving
  2. Create a YAML file named knative-serving.yaml and replace the placeholder FQDN with your wildcard inference domain (for example, runai-inference.tenant-a-corp.com).

    apiVersion: operator.knative.dev/v1beta1
    kind: KnativeServing
    metadata:
    name: knative-serving
    namespace: knative-serving
    spec:
    config:
    config-autoscaler:
    enable-scale-to-zero: "true"
    config-features:
    kubernetes.podspec-affinity: enabled
    kubernetes.podspec-init-containers: enabled
    kubernetes.podspec-persistent-volume-claim: enabled
    kubernetes.podspec-persistent-volume-write: enabled
    kubernetes.podspec-schedulername: enabled
    kubernetes.podspec-securitycontext: enabled
    kubernetes.podspec-tolerations: enabled
    kubernetes.podspec-volumes-emptydir: enabled
    kubernetes.podspec-fieldref: enabled
    kubernetes.containerspec-addcapabilities: enabled
    kubernetes.podspec-nodeselector: enabled
    multi-container: enabled
    kubernetes.podspec-hostipc: enabled
    kubernetes.podspec-hostnetwork: enabled
    domain:
    runai-inference.tenant-a-corp.com: "" # replace with the wildcard FQDN for Inference
    network:
    domainTemplate: '{{.Name}}-{{.Namespace}}.{{.Domain}}'
    ingress-class: kourier.ingress.networking.knative.dev
    default-external-scheme: https
    observability:
    metrics-protocol: "prometheus"
    request-metrics-protocol: "http/protobuf"
    request-metrics-endpoint: "http://prometheus-operated.runai.svc.cluster.local:9090/api/v1/otlp/v1/metrics"
    high-availability:
    replicas: 2
    ingress:
    kourier:
    enabled: true
  3. Apply the changes:

    kubectl apply -f knative-serving.yaml
  4. Configure HAProxy to proxy requests to Kourier / Knative and handle TLS termination using the wildcard certificate. Create a YAML file named knative-ingress.yaml and replace the FQDN placeholders with your wildcard inference domain:

    apiVersion: networking.k8s.io/v1
    kind: Ingress
    metadata:
    name: knative-serving
    namespace: knative-serving
    spec:
    ingressClassName: haproxy
    rules:
    - host: '*.runai-inference.tenant-a-corp.com' # replace with the wildcard FQDN for Inference
    http:
    paths:
    - backend:
    service:
    name: kourier
    port:
    number: 80
    path: /
    pathType: Prefix
    tls:
    - hosts:
    - '*.runai-inference.tenant-a-corp.com' # replace with the wildcard FQDN for Inference
    secretName: runai-cluster-inference-tls-secret
  5. Apply the changes:

    kubectl apply -f knative-ingress.yaml

Cluster-Local Inference

With cluster-local access, inference services are reachable only from inside the cluster through the cluster-internal domain (<service>.<namespace>.svc.cluster.local). This mode is recommended when inference workloads are consumed by other applications running in the same cluster.

On OpenShift Serverless, external access is the platform default; cluster-local must be enabled per inference workload. See the OpenShift tab below.

On Kubernetes, cluster-local access does not require an external DNS record, a wildcard certificate, or an HAProxy ingress because traffic does not leave the cluster.

Follow the Installing Knative instructions or run:

helm repo add knative-operator https://knative.github.io/operator
helm install knative-operator --create-namespace --namespace knativeoperator --version {VERSION} knative-operator/knative-operator

Once installed, follow the steps below:

  1. Create the knative-serving namespace:

    kubectl create ns knative-serving
  2. Create a YAML file named knative-serving.yaml:

    apiVersion: operator.knative.dev/v1beta1
    kind: KnativeServing
    metadata:
    name: knative-serving
    namespace: knative-serving
    spec:
    config:
    config-autoscaler:
    enable-scale-to-zero: "true"
    config-features:
    kubernetes.podspec-affinity: enabled
    kubernetes.podspec-init-containers: enabled
    kubernetes.podspec-persistent-volume-claim: enabled
    kubernetes.podspec-persistent-volume-write: enabled
    kubernetes.podspec-schedulername: enabled
    kubernetes.podspec-securitycontext: enabled
    kubernetes.podspec-tolerations: enabled
    kubernetes.podspec-volumes-emptydir: enabled
    kubernetes.podspec-fieldref: enabled
    kubernetes.containerspec-addcapabilities: enabled
    kubernetes.podspec-nodeselector: enabled
    multi-container: enabled
    kubernetes.podspec-hostipc: enabled
    kubernetes.podspec-hostnetwork: enabled
    domain:
    svc.cluster.local: ""
    network:
    domainTemplate: '{{.Name}}.{{.Namespace}}.{{.Domain}}'
    ingress-class: kourier.ingress.networking.knative.dev
    default-external-scheme: http
    observability:
    metrics-protocol: "prometheus"
    request-metrics-protocol: "http/protobuf"
    request-metrics-endpoint: "http://prometheus-operated.runai.svc.cluster.local:9090/api/v1/otlp/v1/metrics"
    high-availability:
    replicas: 2
    ingress:
    kourier:
    enabled: true
    service-type: ClusterIP
  3. Apply the changes:

    kubectl apply -f knative-serving.yaml

Autoscaling

NVIDIA Run:ai allows for autoscaling a deployment according to the below metrics:

  • Latency (milliseconds)
  • Throughput (requests/sec)
  • Concurrency (requests)

Using a custom metric (for example, Latency) requires installing the Kubernetes Horizontal Pod Autoscaler (HPA). Use the following command to install. Make sure to update the {VERSION} in the below command with a supported Knative version.

kubectl apply -f https://github.com/knative/serving/releases/download/knative-{VERSION}/serving-hpa.yaml

Distributed Inference

NVIDIA Run:ai supports distributed inference (multi-node) deployments using the Leader Worker Set (LWS). To enable this capability, you must install the LWS Helm chart in version 0.7.0 or higher on the tenant’s cluster:

CHART_VERSION=0.7.0
helm install lws oci://registry.k8s.io/lws/charts/lws \
--version=$CHART_VERSION \
--namespace lws-system \
--create-namespace \
--wait --timeout 300s

NIM Operator

The NVIDIA NIM Operator enables Kubernetes cluster administrators to operate the software components and services necessary to deploy NVIDIA NIMs and NVIDIA NeMo microservices in Kubernetes. NVIDIA Run:ai provides out-of-the-box support for submitting NIM Operator workloads via YAML.

Grove

NVIDIA Run:ai uses NVIDIA Grove to orchestrate multi-component, gang-scheduled workloads, such as disaggregated NVIDIA Dynamo inference deployments where a single workload is split into multiple functions (for example, a router, prefill, and decode component), each made up of one or more leader-worker replica sets. Grove acts as the Kubernetes API (CRD) and controller for these pods, and is required alongside the Dynamo Operator for disaggregated Dynamo deployments.

Dynamo

The Dynamo Operator is a Kubernetes operator that simplifies the deployment, configuration, and lifecycle management of DynamoGraphs. NVIDIA Run:ai provides out-of-the-box support for submitting Dynamo workloads via YAML.

Next Steps

With the tenant cluster’s environment prepared, continue to Create a Tenant and Cluster to register and install the cluster.