Internal Ref. |
Issue |
3614288 |
Description: Fixed an issue on special systems with separate power supply that caused the host to hang and RDMA to fail in virtio-net-controller when performing the following steps:
|
Keywords: hotplug, RDMA, virtio-net-controller |
|
Discovered in Version: 32.38.1002 |
|
Fixed in Release: 32.39.2048 |
|
3661385 |
Description: BlueField Arm cores that serve as PCIe Root-Port of PCIe End-Point devices (eg NVMe SSDs) connected to BlueField’s PCIe interfaces may receive MSI-X (used by a device to indicate an event) prior to PCIe CQE writes, resulting in a driver interrupt handler trying to retrieve data in an inconsistent state. |
Keywords: MSI-X, NVMe |
|
Discovered in Version: 32.38.1002 |
|
Fixed in Release: 32.39.2048 |
|
3629353 |
Description: Fixed the cr_space in port configuration to prevent wrong timestamp of cqes. |
Keywords: Hardware timestamp |
|
Discovered in Version: 32.38.1002 |
|
Fixed in Release: 32.39.2048 |
|
3627384 |
Description: Fixed an issue that prevented the PCC flow context database from being cleared when starting a new DOCA PCC application used to avoid the "left state by legacy" active application from impacting the new application's behavior. |
Keywords: PCC flow |
|
Discovered in Version: 32.38.3056 |
|
Fixed in Release: 32.39.2048 |
|
3630586 |
Description: Updated the HW ETS (QETCR RL) default to be per host-port instead of per physical-port to prevent bandwidth degradation. |
Keywords: Performance |
|
Discovered in Version: 32.38.1002 |
|
Fixed in Release: 32.39.2048 |
|
3636595 |
Description: Fixed an issue that caused the TX to hang and create a "TX timeout" error in dmesg after unplugging the device forcefully during server warm reboot. |
Keywords: hotplug, virtio, NVMe, warm reboot, TX timeout |
|
Discovered in Version: 32.38.1002 |
|
Fixed in Release: 32.39.2048 |
|
3653763 |
Description: Fixed the issue that caused the server not to boot up (after power cycle) when there are 31 hotplug devices on a customized server with BlueField-3 DPU with an independent power supply. |
Keywords: Power cycle, hotplug device, server |
|
Discovered in Version: 32.38.1002 |
|
Fixed in Release: 32.39.2048 |
|
3547022 |
Description: Fixed an issue that resulted in reset failure when unloading network drivers on an external host and the sync1 reset is still reported as 'supported' although it is not. |
Keywords: sync1 reset |
|
Discovered in Version: 32.38.1002 |
|
Fixed in Release: 32.39.2048 |
|
3546787 |
Description: Extended the number of elastic buffer lock attempts, to prevent rare cases of Tx issues during Gen1. |
Keywords: PCIe |
|
Discovered in Version: 32.38.1002 |
|
Fixed in Release: 32.39.2048 |
|
3591726 |
Description: Fixed an issue when in LAG mode that resulted in RoCE traffic having less throughput when Congestion Control (CC) mode is enabled than when CC mode is disabled. |
Keywords: Congestion Control, LAG, bond, Bandwidth, RoCE |
|
Discovered in Version: 32.38.1002 |
|
Fixed in Release: 32.39.2048 |
|
3482251 |
Description: Added support for hairpin drop counter in QUERY_VNIC_ENV command. |
Keywords: Hairpin |
|
Discovered in Version: 32.38.1002 |
|
Fixed in Release: 32.39.2048 |
|
3571251 |
Description: Fixed an issue that resulted in migration data corruption when running parallel save_vhca_state/load_vhca_state commands on the same PF. |
Keywords: VF live migration |
|
Discovered in Version: 32.38.1002 |
|
Fixed in Release: 32.39.2048 |
|
3602176 |
Description: Updated OOB counter behavior. |
Keywords: OOB |
|
Discovered in Version: 32.37.1306 |
|
Fixed in Release: 32.39.2048 |
|
3140048 |
Description: The DPC mechanism is currently not supported. |
Keywords: DPC, PCIe |
|
Discovered in Version: 32.37.1306 |
|
Fixed in Release: 32.39.2048 |