image image image image image

On This Page

Chassis Management

clear counters


clear counters [all | interface <type> <number>]

Clears switch counters.

Syntax Description

all

Clears all switch counters.

type

A specific interface type.

number

The interface number.

Default

N/A

Configuration Mode

config

History

3.2.3000
3.6.4000: Added note

Example

switch (config) # clear counters
Related Commands

Notes

 The command also clears storm-control counters

clear system hardware events


clear system hardware events 

Clears all active events.

Syntax Description

N/A 

Default

N/A

Configuration Mode

config

History

3.6.6000

Example

switch (config) # clear system hardware events

Related Commands

show system hardware events

Notes


health


health {max-report-len <length> | re-notif-cntr <counter> | report-clear}

Configures health daemon settings.

Syntax Description

max-report-len <length>

Sets the length of the health report (number of line entries)
Range: 10-2048

re-notif-cntr <counter>

Health control changes notification counter in seconds
Range: 120-7200

report-clear

Clears the health report

Default

max-report-len: 50
re-notif-cntr:

Configuration Mode

config

History

3.1.0000

Example

switch (config) # health re-notif-cntr 125

Related Commands

show health-report

Notes


led uid


led <module> uid <on | off>

Configures the UID LED.

Syntax Description



module

Specifies the module whose UID LED to configure

on

Turns on UID LED

off

Turns off UID LED

Default

N/A

Configuration Mode

config

History


3.6.1002
3.6.2002: 

Example

switch (config) # led MGMT uid on

Related Commands


Notes



power enable


power enable <module name>
no power enable <module name> 

Powers on the module.
The no form of the command shuts down the module.

Syntax Description

module name

Enables power for selected module

Default

Power is enabled on all modules

Configuration Mode

config

History

3.1.0000

Example

switch (config) # power enable L01

Related Commands

show power
show power consumers

Notes

  • It is recommended to run this command prior to extracting a module from the switch system, else errors are printed in the log


system profile


system profile {eth-default | eth-ipv6-max | eth-ipv4-mc-max} [force] 

Optimizes switch system profile to preferred mode.

Syntax Description




eth-default

Balanced Ethernet profile

eth-ipv6-max

Optimized profile for IPv6 scale

eth-ipv4-mc-max

Optimized profile for IPv4 multicast scale

force

Forces operation, without the need for user confirmation

Default

eth-default

Configuration Mode

config

History3.6.6000

Example

switch (config) # system profile eth-default

Related Commands

show system profile

Notes


usb eject


usb eject

Turns off the USB interface gracefully.

Syntax DescriptionN/A

Default

N/A

Configuration Mode

config

History

3.1.0000

Example

switch (config) # usb eject

Related Commands


Notes

Applicable only for systems with USB interface.

show asic-version 


show asic-version 

Displays firmware ASIC version.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000
3.4.2008: Updated example

Example

switch (config) # show asic-version
==================================================
Module             Device              Version
==================================================
MGMT               SPC                 15.0200.0092

Related Commands


Notes


show bios


show bios

Displays the BIOS version information.

Syntax DescriptionN/A

Default

N/A

Configuration Mode

Any command mode

History

3.3.4150

Example

switch (config) # show bios
BIOS version : 4.6.5
BIOS subversion : Official AMI Release
BIOS release date : 07/02/2021

Related Commands


Notes


show cpld 


show cpld

Displays status of all CPLDs in the system.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000
3.3.4302: Updated example
3.10.1000: Updated example to reflect the part number (PN) field
3.10.1100: Updated example to reflect Version Minor

Example
switch (config) # show cpld
----------------------------------------------------------------------------
Name           Type                 Version         Version Minor  PN    
----------------------------------------------------------------------------
Cpld1          CPLD_TOR             9               1              0x0078
Cpld2          CPLD_SWB_UNIFIED     3               3              0x0128
Cpld3          CPLD_LED             1               0              0x00d1

Related Commands


Notes


show fan


show fan 

Displays fans status.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

Example

switch (config) # show fan
-----------------------------------------------------
Module          Device          Fan  Speed     Status
                                     (RPM)
-----------------------------------------------------
FAN1            FAN             F1   9305.00   OK
FAN2            FAN             F1   8823.00   OK
FAN3            FAN             F1   9057.00   OK
FAN4            FAN             F1   9369.00   OK
PS1             FAN             F1   10288.00  OK
PS2             FAN             -    -         NOT PRESENT

Related Commands


Notes


show health-report


show health-report 

Displays health report.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000
3.3.0000: Output update

Example

switch (config) # show health-report
========================
| ALERTS CONFIGURATION |
========================
Re-notification counter (sec):[3600]
Report max counter:           [50]
========================
|    HEALTH REPORT     |
========================
No Health issues file

Related Commands

health

Notes


show inventory


show inventory 

Displays system inventory.

Syntax Description

N/A 

Default

N/A

Configuration Mode

Any command mode

History





3.1.0000
3.4.1604: Removed CPU module output from example
3.5.1000: Removed Type column from example
3.6.1002: Updated example

Example

switch (config) # show inventory
-----------------------------------------------------------------------
Module     Part Number        Serial Number        Asic Rev.    HW Rev.
-----------------------------------------------------------------------
CHASSIS    MSN2100-CB2F       MT1752X06330         N/A          B3
MGMT       MSN2100-CB2F       MT1752X06330         1            B3

Related Commands


Notes


show leds


show leds [<module>]

Displays the LED status of the switch system.

Syntax Description

module

Specifies the module whose LED status to display

Default

N/A

Configuration Mode

Any command mode

History


3.6.1002
3.6.2002: Updated example

Example

switch (config) # show leds
Module       LED                      Status
--------------------------------------------
MGMT         STATUS                   Green
MGMT         FAN1                     Green
MGMT         FAN2                     Green
MGMT         FAN3                     Green
MGMT         FAN4                     Green
MGMT         PS_STATUS                Green
MGMT         PS1                      Green
MGMT         PS2                      Green
MGMT         UID                      Blue

Related Commands


Notes


show memory


show memory 

Displays memory status.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History


3.1.0000
3.7.1000: Updated example

Example
switch (config) # show memory
-----------------------------------------------------------------------
Memory Space  Total       Used        Free        Used+B/C    Free-B/C
-----------------------------------------------------------------------
Physical      15848 MB    2849 MB     12999 MB    3854 MB     11994 MB
Swap          0 MB        0 MB        0 MB

Physical Memory Borrowed for System Buffers and Cache:
  Buffers            : 27 MB
  Cache              : 910 MB
  Total Buffers/Cache: 937 MB

Related Commands


Notes


show module


show module

Displays modules status.

Syntax Description

N/A 

Default

N/A

Configuration Mode

Any command mode

History




3.1.0000
3.3.0000: Added “Is Fatal” column
3.4.2008: Updated command output
3.4.3000: Updated command output and added note

Example

switch (config) # show module
======================
 Module    Status
======================
 MGMT      ready
 FAN1      ready
 FAN2      ready
 PS1       ready
 PS2       not-present

Related Commands


Notes

The Status column may have one of the following values: error, fatal, not-present, powered-off, powered-on, ready.

show power


show power

Displays power supplies and power usage.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History


3.1.0000
3.5.1000: Updated example

Example
switch (config) # show power
----------------------------------------------------------------------------------
Module   Device     Sensor Power   Voltage   Current   Capacity   Feed   Status
                           [Watts] [Volts]  [Amp]      [Watts]
----------------------------------------------------------------------------------
PS1      power-mon  input  32.25   12.11    1.26       800.00     DC     OK
PS2      power-mon  input  46.56   12.13    2.33       800.00     DC     OK

Related Commands


Notes


show power consumers 


show power consumers

Displays power consumption information.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History


3.1.0000
3.5.1000: Updated example

Example
switch (config) # show power consumers
-------------------------------------------------------------------------
Module  Device            Sensor  Power   Voltage  Current  Status
                                  [Watts] [Volts]  [Amp]
-------------------------------------------------------------------------
MGMT    CURR_MONITOR      12V     52.96   11.71    4.52     OK
PS1 power-mon input 252.00 12.00 20.25 OK
PS2 power-mon input 280.00 12.03 23.25 OK

Total power used : 52.96 Watts

Related Commands


Notes


show protocols


show protocols

Displays all protocols enabled in the system.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.2.3000
3.3.4550: Updated example
3.6.1002: Updated example

Example

switch (config) # show protocols

Ethernet                 enabled
 spanning-tree           rst
 lacp                    disabled
 lldp                    disabled
 igmp-snooping           disabled
 ets                     enabled
 priority-flow-control   disabled
 sflow                   disabled
 openflow                disabled
 mlag                    disabled
 dot1x                   disabled
 isolation-group         disabled

IP routing               disabled
 bgp                     disabled
 pim                     disabled
 vrrp                    disabled
 ospf                    disabled
 magp                    disabled
 dhcp-relay              disabled

Related Commands


Notes


show resources


show resources

Displays system resources.

Syntax Description

N/A 

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

Example

switch (config) # show resources
Total      Used      Free
Physical  2027 MB    761 MB   1266 MB
Swap         0 MB      0 MB      0 MB

Number of CPUs:    1
CPU load averages: 0.11 / 0.23 / 0.23

CPU 1
  Utilization:                5%
  Peak Utilization Last Hour: 19% at 2012/02/15 13:26:19
  Avg. Utilization Last Hour: 7%

Related Commands


Notes


show system capabilities


show system capabilities

Displays system capabilities.

Syntax Description

N/A 

Default

N/A

Configuration Mode

Any command mode

History 

3.1.0000
3.3.0000: Added gateway support
3.6.1002: Updated example
3.7.0000: Updated example

Example

switch (config) # show system capabilities
Ethernet: Supported, L2, L3
Ethernet Max licensed speed: 100Gb

Related Commands

show system profile

Notes


show system hardware events


show system hardware events <family-name> [clear-on-read]

Displays all active events.

Syntax Description

family-name

Displays all active events per event family:

  • ethernet
  • tunnel
  • ip

clear-on-read

Clears all active events after displaying them

Default

N/A

Configuration Mode

Any command mode

History

3.6.6000

Example

switch (config) # show system hardware events clear-on-read

Ethernet:         smac is mc;
                  smac equal dmac;  
IP:               packet to router is not ip;  
Tunnel:

Related Commands


Notes


show system mac


show system mac

Displays system MAC address.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

Example

switch (config) # show system mac
00:02:c9:5e:AF:18

Related Commands

N/A

Notes


show system profile


show system profile 

Displays system profile.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History


3.2.0000
3.7.0000: Updated example 

Example

switch (config) # show system profile

Profile: eth-default

Related Commands

system profile

Notes


show system profile detailed


show system profile detailed

Displays detailed system profile.

Syntax Description

N/A 

Default

N/A

Configuration Mode

Any command mode

History

3.6.6000

Example

switch (config) # show system profile detailed 

Profile: eth-default

-----------------------------------------------
Parameter                  Guaranteed Max Value
-----------------------------------------------
FDB size                   102400
IPMC-L2 lists              10240
IPMC-L3 lists              10240
IPv4 MC/IGMP routes        10240
IPv4 neighbors             51200
IPv6 neighbors             8192
IPv4 routes                100000
IPv6 shorts                51200
IPv6 routes                21504
VRF                        64
RIF                        999

Related Commands

system profile

Notes


show system type


show system type

Displays system type.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.5.1000 

Example

switch (config) # show system type
SN2100

Related Commands


Notes


show temperature


show temperature 

Displays system temperature sensors status.

Syntax Description

N/A 

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

Example

switch (config) # show temperature
---------------------------------------------------------
Module      Component              Reg  CurTemp    Status
                                        (Celsius)
---------------------------------------------------------
MGMT        SPC                    T1   43.00      OK
MGMT        Ports AMB temp         T1   31.00      OK
MGMT        Board AMB temp         T1   30.00      OK
MGMT        CPU Core Sensor        T1   23.00      OK
MGMT        CPU Core Sensor        T2   23.00      OK
MGMT        CPU Core Sensor        T3   24.00      OK
MGMT        CPU Core Sensor        T4   24.00      OK

Related Commands


Notes


show version


show version

Displays version information for the currently running system image.

Syntax Description

N/A 

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

Example

switch (config) # show version
Product name:      Onyx
Product release:   3.6.8008
Build ID:          #1-dev
Build date:        2018-07-18 13:46:44
Target arch:       x86_64
Target hw:         x86_64
Built by:          jenkins@c5de6027485e
Version summary:   X86_64 3.6.8008 2018-07-18 13:46:44 x86_64

Product model:     x86
Host ID:           7CFE9058E01E
System UUID:       03000200-0400-0500-0006-000700080009

Uptime:            16h 50m 41.260s
CPU load averages: 2.38 / 2.25 / 2.24
Number of CPUs:    2
System memory:     2860 MB used / 12988 MB free / 15848 MB total
Swap:              0 MB used / 0 MB free / 0 MB total

Related Commands


Notes


show version concise


show version concise

Displays concise version information for the currently running system image.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

Example

switch (config) # show version concise
X86_64 3.6.4006 2017-07-03 16:17:39 x86_64

Related Commands


Notes


show voltage


show voltage 

Displays voltage level measurements on different sensors.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History


3.1.0000
3.3.5006: Updated example

Example
switch (config) # show voltage
============================================================================================
Module  Power Meter           Reg                   Expected  Actual   Status  High   Low
                                                    Voltage   Voltage          Range  Range
============================================================================================
MGMT    BOARD_MONITOR         USB 5V sensor         5.00      5.15     OK      5.55   4.45
MGMT    BOARD_MONITOR         Asic I/O sensor       2.27      2.11     OK      2.55   1.99
MGMT    BOARD_MONITOR         1.8V sensor           1.80      1.79     OK      2.03   1.57
MGMT    BOARD_MONITOR         SYS 3.3V sensor       3.30      3.28     OK      3.68   2.92
MGMT    BOARD_MONITOR         CPU 0.9V sensor       0.90      0.93     OK      1.04   0.76
MGMT    BOARD_MONITOR         1.2V sensor           1.20      1.19     OK      1.37   1.03
MGMT    CPU_BOARD_MONITOR     12V sensor            12.00     11.67    OK      13.25  10.75
MGMT    CPU_BOARD_MONITOR     12V sensor            2.50      2.46     OK      2.80   2.20
MGMT    CPU_BOARD_MONITOR     2.5V sensor           3.30      3.26     OK      3.68   2.92
MGMT    CPU_BOARD_MONITOR     SYS 3.3V sensor       3.30      3.24     OK      3.68   2.92
MGMT    CPU_BOARD_MONITOR     SYS 3.3V sensor       1.80      1.79     OK      2.03   1.57
MGMT    CPU_BOARD_MONITOR     1.8V sensor           1.20      1.24     OK      1.37   1.03

Related Commands


Notes