NVIDIA BlueField DPU BSP v4.0.3
1.0

Deploying NVIDIA Converged Accelerator

Note

It is recommended to upgrade your BlueField product to the latest software and firmware versions available to benefit from new features and latest bug fixes.

This section assumes that you have installed the BlueField OS BFB on your NVIDIA® Converged Accelerator using any of the following guides:

NVIDIA® CUDA® (GPU driver) must be installed in order to use the GPU. For information on how to install CUDA on your Converged Accelerator, refer to NVIDIA CUDA Installation Guide for Linux.

After installing the BFB, you may now select the mode you want your NVIDIA Converged Accelerator to operate in.

  • Standard (default) – the NVIDIA® BlueField® DPU and the GPU operate separately (GPU is owned by the host)

  • BlueField-X – the GPU is exposed to the DPU and is no longer visible on the host (GPU is owned by the DPU)

Warning

It is is important to learn your DPU's device-id for performing some of the software installations or upgrades in this guide.

To determine the device ID of the DPUs on your setup, run:

Copy
Copied!
            

mst start mst status -v

Example output:

Copy
Copied!
            

MST modules: ------------ MST PCI module is not loaded MST PCI configuration module loaded PCI devices: ------------ DEVICE_TYPE MST PCI RDMA NET NUMA BlueField2(rev:1) /dev/mst/mt41686_pciconf0.1 3b:00.1 mlx5_1 net-ens1f1 0   BlueField2(rev:1) /dev/mst/mt41686_pciconf0 3b:00.0 mlx5_0 net-ens1f0 0   BlueField3(rev:1)       /dev/mst/mt41692_pciconf0.1   e2:00.1   mlx5_1          net-ens7f1np1             4   BlueField3(rev:1)       /dev/mst/mt41692_pciconf0     e2:00.0   mlx5_0          net-ens7f0np0             4

The device IDs for the BlueField-2 and BlueField-3 DPUs in this example are /dev/mst/mt41686_pciconf0 and /dev/mst/mt41692_pciconf0 respectively.

BlueField-X Mode

  1. Run the following command from the host:

    Copy
    Copied!
                

    mlxconfig -d /dev/mst/<device-name> s PCI_DOWNSTREAM_PORT_OWNER[4]=0xF

  2. Power cycle the host for the configuration to take effect.

Standard Mode

To return the DPU from BlueField-X mode to Standard mode:

  1. Run the following command from the host:

    Copy
    Copied!
                

    mlxconfig -d /dev/mst/<device-name> s PCI_DOWNSTREAM_PORT_OWNER[4]=0x0

  2. Power cycle the host for the configuration to take effect.

Use the following command from host or from DPU:

Copy
Copied!
            

$ sudo mlxconfig -d /dev/mst/<device-name> q PCI_DOWNSTREAM_PORT_OWNER[4]

Example of Standard mode output:

Copy
Copied!
            

Device #1: ----------   [...]   Configurations: Next Boot PCI_DOWNSTREAM_PORT_OWNER[4] DEVICE_DEFAULT(0)

Example of BlueField-X mode output:

Copy
Copied!
            

Device #1: ---------- [...]   Configurations: Next Boot PCI_DOWNSTREAM_PORT_OWNER[4]        EMBEDDED_CPU(15)

The following are example outputs for when the DPU is configured to BlueField-X mode.

The GPU is no longer visible from the host:

Copy
Copied!
            

root@host:~# lspci | grep -i nv None

The GPU is now visible from the DPU:

Copy
Copied!
            

ubuntu@dpu:~$ lspci | grep -i nv 06:00.0 3D controller: NVIDIA Corporation GA20B8 (rev a1)

Firmware upgrade of BMC and CEC components using BMC can be performed from a remote server using the Redfish interface. The following table presents commands available for performing the upgrade:

No. Function Command Required for BMC / CEC Update Description

1

Establish Redfish connection session

Copy
Copied!
            

export token=`curl -k -H "Content-Type: application/json" -X POST https://<bmc_ip>/login -d '{"username" : "root", "password" : "<password>"}' | grep token | awk '{print $2;}' | tr -d '"'`

Where:

  • bmc_ip – BMC IP address

  • password – Password of root account

BMC
CEC

Establish Redfish connection session

2

Trigger a secure firmware update

Copy
Copied!
            

curl -k -H "X-Auth-Token: <token>" -H "Content-Type: application/octet-stream" -X POST -T <package_path> https://<bmc_ip>/redfish/v1/UpdateService

Where:

  • bmc_ip – BMC IP address

  • token – session token received when establishing connection

  • package_path – firmware update package path

BMC
CEC

Triggers the secure update and starts tracking the secure update progress

3

Track secure firmware update progress

Copy
Copied!
            

curl -k -H "X-Auth-Token: <token>" -X GET https://<bmc_ip>/redfish/v1/TaskService/Tasks

Find the current task ID in the response and use it for checking the progress:

Copy
Copied!
            

curl -k -H "X-Auth-Token: <token>" -X GET https://<bmc_ip>/redfish/v1/TaskService/Tasks/<task_id> | jq -r ' .PercentComplete'

Where:

  • bmc_ip – BMC IP address

  • token – session token received when establishing connection

  • task_id – Task ID

BMC
CEC

Tracks the firmware update progress

4

Reset/reboot a BMC

Copy
Copied!
            

curl -k -H "X-Auth-Token: <token>" -H "Content-Type: application/json" -X POST -d '{"ResetType": "GracefulRestart"}' https://<bmc_ip>/redfish/v1/Managers/Bluefield_BMC/Actions/Manager.Reset

Where:

  • bmc_ip – BMC IP address

  • token – session token received when establishing connection

BMC

Resets/reboots the BMC

5

Fetch running BMC firmware version

For BlueField-3:

Copy
Copied!
            

curl -k -H "X-Auth-Token: <token>" -X GET https://<bmc_ip>/redfish/v1/UpdateService/FirmwareInventory/BMC_Firmware | jq -r ' .Version'

Where:

  • bmc_ip – BMC IP address

  • token – session token received when establishing connection

BMC

Fetches the running firmware version from BMC

For BlueField-2:

Copy
Copied!
            

curl -k -H "X-Auth-Token: <token>" -X GET https://<bmc_ip>/redfish/v1/UpdateService/FirmwareInventory

Fetch the current firmware ID and then perform:

Copy
Copied!
            

curl -k -H "X-Auth-Token: <token>" -X GET https://<bmc_ip>/redfish/v1/UpdateService/FirmwareInventory/<firmware_id>_BMC_Firmware | jq -r ' .Version'

Where:

  • bmc_ip – BMC IP address

  • token – session token received when establishing connection

6

Fetch running CEC firmware version

Copy
Copied!
            

curl -k -H "X-Auth-Token: <token>" -X GET https://<bmc_ip>/redfish/v1/UpdateService/FirmwareInventory/Bluefield_FW_ERoT | jq -r ' .Version'

Where:

  • bmc_ip – BMC IP address

  • token – session token received when establishing connection

CEC

Fetches the running firmware version from CEC

BMC Update

After initiating the BMC secure update with the command #2 to from the previous table, a response similar to the following is received:

Copy
Copied!
            

curl -k -H "X-Auth-Token: <token>" -H "Content-Type: application/octet-stream" -X POST -T <package_path> https://<bmc_ip>/redfish/v1/UpdateService   { "@odata.id": "/redfish/v1/TaskService/Tasks/0", "@odata.type": "#Task.v1_4_3.Task", "Id": "0", "TaskState": "Running" }

Command #3 from the previous table can be used to track secure firmware update progress. For instance:

Copy
Copied!
            

curl -k -H "X-Auth-Token: <token>" -X GET https://<bmc_ip>/redfish/v1/TaskService/Tasks/0 | jq -r ' .PercentComplete'   % Total % Received % Xferd Average Speed Time Time Time Current Dload Upload Total Spent Left Speed 100 2123 100 2123 0 0 38600 0 --:--:-- --:--:-- --:--:-- 37910 20

Command #3 is used to verify the task has completed because during the update procedure the reboot option is disabled. When "PercentComplete" reaches 100, command #4 is used to reboot the BMC. For example:

Copy
Copied!
            

curl -k -H "X-Auth-Token: <token>" -X GET https://<bmc_ip>/redfish/v1/TaskService/Tasks/0 | jq -r ' .PercentComplete' % Total % Received % Xferd Average Speed Time Time Time Current Dload Upload Total Spent Left Speed 100 3822 100 3822 0 0 81319 0 --:--:-- --:--:-- --:--:-- 81319 100   curl -k -H "X-Auth-Token: <token>" -H "Content-Type: application/octet-stream" -X POST -d '{"ResetType": "GracefulRestart"}' https://<bmc_ip>/redfish/v1/Managers/Bluefield_BMC/Actions/Manager.Reset { "@Message.ExtendedInfo": [ { "@odata.type": "#Message.v1_1_1.Message", "Message": "The request completed successfully.", "MessageArgs": [], "MessageId": "Base.1.13.0.Success", "MessageSeverity": "OK", "Resolution": "None" } ] }

Command #5 can be used to verify the current BMC firmware version after reboot:

  • For BlueField-3:

    Copy
    Copied!
                

    curl -k -H "X-Auth-Token: <token>" -X GET https://<bmc_ip>/redfish/v1/UpdateService/FirmwareInventory/BMC_Firmware | jq -r ' .Version'   % Total % Received % Xferd Average Speed Time Time Time Current Dload Upload Total Spent Left Speed 100 513 100 513 0 0 9679 0 --:--:-- --:--:-- --:--:-- 9679

  • For BlueField-2:

    1. Fetch the firmware ID from FirmwareInventory:

      Copy
      Copied!
                  

      curl -k -H "X-Auth-Token: <token>" -X GET https:/<bmc_ip>/redfish/v1/UpdateService/FirmwareInventory/ { "@odata.id": "/redfish/v1/UpdateService/FirmwareInventory", "@odata.type": "#SoftwareInventoryCollection.SoftwareInventoryCollection", "Members": [ { "@odata.id": "/redfish/v1/UpdateService/FirmwareInventory/8c8549f3_BMC_Firmware" …

    2. Use command #5 with the fetched firmware ID in the previous step:

      Copy
      Copied!
                  

      curl -k -H "X-Auth-Token: <token>" -X GET https:/<bmc_ip>/redfish/v1/UpdateService/FirmwareInventory/8c8549f3_BMC_Firmware | jq -r ' .Version'   % Total % Received % Xferd Average Speed Time Time Time Current Dload Upload Total Spent Left Speed 100 471 100 471 0 0 622 0 --:--:-- --:--:-- --:--:-- 621 bmc-23.04

CEC Update

After initiating the BMC secure update with the command #2 to from the previous table, a response similar to the following is received:

Copy
Copied!
            

curl -k -H "X-Auth-Token: <token>" -H "Content-Type: application/octet-stream" -X POST -T <package_path> https://<bmc_ip>/redfish/v1/UpdateService { "@odata.id": "/redfish/v1/TaskService/Tasks/0", "@odata.type": "#Task.v1_4_3.Task", "Id": "0", "TaskState": "Running" }

Command #3 can be used to track the progress of the CEC firmware update. For example:

Copy
Copied!
            

curl -k -H "X-Auth-Token: <token>" -X GET https://<bmc_ip>/redfish/v1/TaskService/Tasks/0 | jq -r ' .PercentComplete' % Total % Received % Xferd Average Speed Time Time Time Current Dload Upload Total Spent Left Speed 100 2123 100 2123 0 0 38600 0 --:--:-- --:--:-- --:--:-- 37910 100

After the CEC secure update operation is complete, a power cycle or cold reset of the BlueField-3 DPU must be manually triggered to apply the changes once the update is finished.

Command #6 can be used to verify the current CEC firmware version after reboot:

Copy
Copied!
            

curl -k -H "X-Auth-Token: <token>" -X GET https://<bmc_ip>/redfish/v1/UpdateService/FirmwareInventory/Bluefield_FW_ERoT | jq -r ' .Version'   % Total % Received % Xferd Average Speed Time Time Time Current Dload Upload Total Spent Left Speed 100 421 100 421 0 0 1172 0 --:--:-- --:--:-- --:--:-- 1172 19-4


Get GPU Firmware

Copy
Copied!
            

smbpbi: (See SMBPBI spec)   root@dpu:~# i2cset -y 3 0x4f 0x5c 0x05 0x08 0x00 0x80 s root@dpu:~# i2cget -y 3 0x4f 0x5c ip 5 5: 0x04 0x05 0x08 0x00 0x5f root@dpu:~# i2cget -y 3 0x4f 0x5d ip 5 5: 0x04 0x39 0x32 0x2e 0x30 root@dpu:~# root@dpu:~# root@dpu:~# i2cset -y 3 0x4f 0x5c 0x05 0x08 0x01 0x80 s root@dpu:~# i2cget -y 3 0x4f 0x5c ip 5 5: 0x04 0x05 0x08 0x01 0x5f root@dpu:~# i2cget -y 3 0x4f 0x5d ip 5 5: 0x04 0x30 0x2e 0x36 0x42 root@dpu:~# i2cset -y 3 0x4f 0x5c 0x05 0x08 0x02 0x80 s root@dpu:~# i2cget -y 3 0x4f 0x5c ip 5 5: 0x04 0x05 0x08 0x02 0x5f root@dpu:~# i2cget -y 3 0x4f 0x5d ip 5 5: 0x04 0x2e 0x30 0x30 0x2e root@dpu:~# i2cset -y 3 0x4f 0x5c 0x05 0x08 0x03 0x80 s root@dpu:~# i2cget -y 3 0x4f 0x5c ip 5 5: 0x04 0x05 0x08 0x03 0x5f root@dpu:~# i2cget -y 3 0x4f 0x5d ip 5 5: 0x04 0x30 0x31 0x00 0x00 root@dpu:~#   39 32 2e 30 30 2e 36 42 2e 30 30 2e 30 31 00 00 → 92.00.6B.00.01


Updating GPU Firmware

Copy
Copied!
            

root@dpu:~# scp root@10.23.201.227:/<path-to-fw-bin>/1004_0230_891__92006B0001-dbg-ota.bin /tmp/gpu_images/ root@10.23.201.227's password: 1004_0230_891__92006B0001-dbg-ota.bin 100% 384KB 384.4KB/s 00:01   root@dpu:~# cat /tmp/gpu_images/progress.txt TaskState="Running" TaskStatus="OK" TaskProgress="50"   root@dpu:~# cat /tmp/gpu_images/progress.txt TaskState="Running" TaskStatus="OK" TaskProgress="50"   root@dpu:~# cat /tmp/gpu_images/progress.txt TaskState=Frimware update succeeded. TaskStatus=OK TaskProgress=100