This reference lists the threshold-based events that UFM supports, each including a set of attributes listed below. You can view these messages through TBD. For details about configuring notifications for these events, refer to TBD.
Event ID: Unique event identifier
Event Name: Short description of the event
To log: A flag which defines whether the event will be sent to UFM events log or not (1 or 0, respectively).
Alarm: A flag which defines whether UFM alarm is generated when the specified event is triggered by UFM (1 means an alarm is generated). Alarms are used to allow a notification with significant indication.
Default Severity: Indicates the alarm severity (Info, Warning, Minor, Critical)
Default Threshold: Event dependent threshold (for example, event occurrence, counter threshold or temperature threshold).
Default TTL: TTL (Alarm Time to Live) sets the time during which the alarm on the event is visible on UFM Web UI. TTL is defined in seconds. CAUTION: Setting the TTL to 0 makes the alarm permanent, meaning that the alarm does not disappear from the Web UI until cleared manually.
Related Object: The object (context) to which the UFM event is related to (port, switch, gateway, grid, etc).
Category: Indicates the category to which the event is related to.
Source: Indicates the origin source of the specified event (SM, Telemetry, Licensing, UFM)
For information about defining event policy, see Configuring Event Management.
Event ID | Event Name | To Log | Alarm | Default Severity | Default Threshold | Default TTL | Related Object | Category | Source |
64 | GID Address In Service | 1 | 0 | Info | 1 | 300 | Port | Fabric Notification | SM |
65 | GID Address Out of Service | 1 | 0 | Warning | 1 | 300 | Port | Fabric Notification | SM |
66 | New MCast Group Created | 1 | 0 | Info | 1 | 300 | Port | Fabric Notification | SM |
67 | MCast Group Deleted | 1 | 0 | Info | 1 | 300 | Port | Fabric Notification | SM |
110 | Symbol Error | 1 | 1 | Warning | 200 | 300 | Port | Hardware | Telemetry |
111 | Link Error Recovery | 1 | 1 | Minor | 1 | 300 | Port | Hardware | Telemetry |
112 | Link Downed | 1 | 1 | Critical | 1 | 300 | Port | Hardware | Telemetry |
113 | Port Receive Errors | 1 | 1 | Minor | 5 | 300 | Port | Hardware | Telemetry |
114 | Port Receive Remote Physical Errors | 0 | 0 | Minor | 5 | 300 | Port | Hardware | Telemetry |
115 | Port Receive Switch Relay Errors | 1 | 1 | Minor | 999 | 300 | Port | Fabric Configuration | Telemetry |
116 | Port Xmit Discards | 1 | 1 | Minor | 200 | 300 | Port | Communication Error | Telemetry |
117 | Port Xmit Constraint Errors | 1 | 1 | Minor | 200 | 300 | Port | Communication Error | Telemetry |
118 | Port Receive Constraint Errors | 1 | 1 | Minor | 200 | 300 | Port | Communication Error | Telemetry |
119 | Local Link Integrity Errors | 1 | 1 | Minor | 5 | 300 | Port | Hardware | Telemetry |
120 | Excessive Buffer Overrun Errors | 1 | 1 | Minor | 100 | 300 | Port | Communication Error | Telemetry |
121 | VL15 Dropped | 1 | 1 | Minor | 50 | 300 | Port | Communication Error | Telemetry |
122 | Congested Bandwidth (%) Threshold Reached | 1 | 1 | Minor | 10 | 300 | Port | Hardware | Telemetry |
123 | Port Bandwidth (%) Threshold Reached | 1 | 1 | Minor | 95 | 300 | Port | Communication Error | Telemetry |
130 | Non-optimal link width | 1 | 1 | Minor | 1 | 0 | Port | Hardware | SM |
134 | T4 Port Congested Bandwidth | 1 | 1 | Warning | 10 | 300 | Port | Communication Error | Telemetry |
141 | Flow Control Update Watchdog Timer Expired | 1 | 0 | Warning | 1 | 300 | Port | Hardware | SM |
144 | Capability Mask Modified | 1 | 0 | Info | 1 | 300 | Port | Fabric Notification | SM |
145 | System Image GUID changed | 1 | 0 | Info | 1 | 300 | Port | Communication Error | SM |
156 | Link Speed Enforcement Disabled | 1 | 0 | Critical | 0 | 300 | Site | Fabric Notification | SM |
250 | Running in Limited Mode | 1 | 1 | Critical | 1 | 0 | Grid | Maintenance | Licensing |
251 | Switching to Limited Mode | 1 | 1 | Critical | 1 | 0 | Grid | Maintenance | Licensing |
252 | License Expired | 1 | 1 | Warning | 1 | 0 | Grid | Maintenance | Licensing |
253 | Duplicated licenses | 1 | 0 | Critical | 1 | 0 | Grid | Maintenance | Licensing |
254 | License Limit Exceeded | 1 | 0 | Critical | 1 | 0 | Grid | Maintenance | Licensing |
255 | License is About to Expire | 1 | 0 | Warning | 1 | 0 | Grid | Maintenance | Licensing |
256 | Bad M_Key | 1 | 0 | Minor | 1 | 300 | Port | Security | SM |
257 | Bad P_Key | 1 | 0 | Minor | 1 | 300 | Port | Security | SM |
258 | Bad Q_Key | 1 | 0 | Minor | 1 | 300 | Port | Security | SM |
259 | Bad P_Key Switch External Port | 1 | 0 | Critical | 1 | 300 | Port | Security | SM |
328 | Link is Up | 1 | 0 | Info | 1 | 0 | Link | Fabric Topology | SM |
329 | Link is Down | 1 | 0 | Warning | 1 | 0 | Site | Fabric Topology | SM |
331 | Node is Down | 1 | 0 | Warning | 1 | 0 | Site | Fabric Topology | SM |
332 | Node is Up | 1 | 0 | Info | 1 | 300 | Site | Fabric Topology | SM |
336 | Port Action Succeeded | 1 | 0 | Info | 1 | 0 | Port | Maintenance | UFM |
337 | Port Action Failed | 1 | 0 | Minor | 1 | 0 | Port | Maintenance | UFM |
338 | Device Action Succeeded | 1 | 0 | Info | 1 | 0 | Port | Maintenance | UFM |
339 | Device Action Failed | 1 | 0 | Minor | 1 | 0 | Port | Maintenance | UFM |
344 | Partial Switch ASIC Failure | 1 | 1 | Critical | 1 | 0 | Switch | Maintenance | UFM |
370 | Gateway Ethernet Link State Changed | 1 | 0 | Warning | 1 | 0 | Gateway | Gateway | SM |
371 | Gateway Reregister Event Received | 1 | 0 | Warning | 1 | 0 | Gateway | Gateway | SM |
372 | Number of Gateways Changed | 1 | 0 | Warning | 1 | 0 | Gateway | Gateway | SM |
373 | Gateway will be Rebooted | 1 | 0 | Warning | 1 | 0 | Gateway | Gateway | SM |
374 | Gateway Reloading Finished | 1 | 0 | Info | 1 | 0 | Gateway | Gateway | SM |
380 | Switch Upgrade Error | 1 | 1 | Critical | 1 | 0 | Switch | Maintenance | UFM |
381 | Switch Upgrade Failed | 1 | 0 | Info | 1 | 0 | Switch | Maintenance | UFM |
328 | Module status NOT PRESENT | 1 | 1 | Warning | 1 | 420 | Switch | Module Status | UFM |
383 | Host Upgrade Failed | 1 | 0 | Info | 1 | 0 | Computer | Maintenance | UFM |
384 | Switch Module Powered Off | 1 | 1 | Info | 1 | 420 | Switch | Module Status | UFM |
385 | Switch FW Upgrade Started | 1 | 0 | Info | 1 | 0 | Switch | Maintenance | UFM |
386 | Switch SW Upgrade Started | 1 | 0 | Info | 1 | 0 | Switch | Maintenance | UFM |
387 | Switch Upgrade Finished | 1 | 0 | Info | 1 | 0 | Switch | Maintenance | UFM |
388 | Host FW Upgrade Started | 1 | 0 | Info | 1 | 0 | Computer | Maintenance | UFM |
389 | Host SW Upgrade Started | 1 | 0 | Info | 1 | 0 | Computer | Maintenance | UFM |
391 | Switch Module Removed | 1 | 0 | Info | 1 | 0 | Switch | Fabric Notification | Switch |
392 | Module Temperature Threshold Reached | 1 | 0 | Info | 40 | 0 | Module | Hardware | Switch |
393 | Switch Module Added | 1 | 0 | Info | 1 | 0 | Switch | Fabric Notification | Switch |
394 | Module Status FAULT | 1 | 1 | Critical | 1 | 420 | Switch | Module Status | Switch |
395 | Device Action Started | 1 | 0 | Info | 1 | 0 | Port | Maintenance | UFM |
396 | Site Action Started | 1 | 0 | Info | 1 | 0 | Port | Maintenance | UFM |
397 | Site Action Failed | 1 | 0 | Minor | 1 | 0 | Port | Maintenance | UFM |
398 | Switch Chip Added | 1 | 0 | Info | 1 | 0 | Switch | Fabric Notification | Switch |
399 | Switch Chip Removed | 1 | 0 | Critical | 1 | 0 | Switch | Fabric Notification | Switch |
403 | Device Pending Reboot | 1 | 1 | Warning | 0 | 300 | Device | Maintenance | UFM |
404 | System Information is missing | 1 | 1 | Warning | 1 | 300 | Switch | Communication Error | UFM |
405 | Switch Identity Validation Failed | 1 | 1 | Warning | 1 | 300 | Switch | Communication Error | UFM |
406 | Switch System Information is missing | 1 | 1 | Waring | 1 | 300 | Switch | Communication Error | UFM |
407 | COMEX Ambient Temperature Threshold Reached | 1 | 1 | Minor | 60 | 300 | Switch | Hardware | Switch |
408 | Switch is Unresponsive | 1 | 1 | Critical | 1 | 300 | Switch | Communication Error | UFM |
502 | Device Upgrade Finished | 1 | 0 | Info | 1 | 300 | Device | Maintenance | UFM |
506 | Device Upgrade Finished | 1 | 0 | Info | 1 | 300 | Device | Maintenance | UFM |
508 | Core Dump Created | 1 | 1 | Info | 1 | 300 | Grid | Maintenance | UFM |
510 | SM Failover | 0 | 1 | Critical | 1 | 300 | Grid | Fabric Notification | SM |
511 | SM State Change | 0 | 1 | Info | 1 | 300 | Grid | Fabric Notification | SM |
512 | SM UP | 0 | 1 | Info | 1 | 300 | Grid | Fabric Notification | SM |
513 | SM System Log Message | 0 | 1 | Minor | 1 | 300 | Grid | Fabric Notification | SM |
514 | SM LID Change | 0 | 1 | Warning | 1 | 300 | Grid | Fabric Notification | SM |
515 | Fabric Health Report Info | 1 | 1 | Info | 1 | 300 | Grid | Fabric Notification | UFM |
516 | Fabric Health Report Warning | 1 | 1 | Warning | 1 | 300 | Grid | Fabric Notification | UFM |
517 | Fabric Health Report Error | 1 | 1 | Critical | 1 | 300 | Grid | Fabric Notification | UFM |
518 | UFM-related process is down | 1 | 1 | Critical | 1 | 300 | Grid | Maintenance | UFM |
519 | Logs purge failure | 1 | 1 | Minor | 1 | 300 | Grid | Maintenance | UFM |
520 | Restart of UFM-related process succeeded | 1 | 1 | Info | 1 | 300 | Grid | Maintenance | UFM |
521 | UFM is being stopped | 1 | 1 | Critical | 1 | 300 | Grid | Maintenance | UFM |
522 | UFM is being restarted | 1 | 1 | Critical | 1 | 300 | Grid | Maintenance | UFM |
523 | UFM failover is being attempted | 1 | 1 | Info | 1 | 300 | Grid | Maintenance | UFM |
524 | UFM cannot connect to DB | 1 | 1 | Critical | 1 | 300 | Grid | Maintenance | UFM |
525 | Disk utilization threshold reached | 1 | 1 | Critical | 1 | 300 | Grid | Maintenance | UFM |
526 | Memory utilization threshold reached | 1 | 1 | Critical | 1 | 300 | Grid | Maintenance | UFM |
527 | CPU utilization threshold reached | 1 | 1 | Critical | 1 | 300 | Grid | Maintenance | UFM |
528 | Fabric interface is down | 1 | 1 | Critical | 1 | 300 | Grid | Maintenance | UFM |
529 | UFM standby server problem | 1 | 1 | Critical | 1 | 300 | Grid | Maintenance | UFM |
530 | SM is down | 1 | 1 | Critical | 1 | 300 | Grid | Maintenance | UFM |
531 | DRBD Bad Condition | 1 | 1 | Critical | 1 | 300 | Grid | Maintenance | UFM |
532 | Remote UFM-SM Sync | 1 | 1 | Info | 1 | 0 | Grid | Maintenance | UFM |
533 | Remote UFM-SM problem | 1 | 1 | Critical | 1 | 0 | Site | Maintenance | UFM |
535 | MH Purge Failed | 1 | 1 | Warning | 1 | 300 | Grid | Maintenance | UFM |
536 | UFM Health Watchdog Info | 1 | 1 | Info | 1 | 300 | Grid | Maintenance | UFM |
537 | UFM Health Watchdog Critical | 1 | 1 | Critical | 1 | 300 | Grid | Maintenance | UFM |
538 | Time Diff Between HA Servers | 1 | 1 | Warning | 1 | 300 | Grid | Maintenance | UFM |
539 | DRBD TCP Connection Performance | 1 | 1 | Warning | 1 | 900 | Grid | Maintenance | UFM |
540 | Daily Report Completed successfully | 1 | 0 | Info | 1 | 300 | Grid | Maintenance | UFM |
541 | Daily Report Completed with Error | 1 | 0 | Minor | 1 | 300 | Grid | Maintenance | UFM |
542 | Daily Report Failed | 1 | 0 | Critical | 1 | 300 | Grid | Maintenance | UFM |
543 | Daily Report Mail Sent successfully | 1 | 0 | Info | 1 | 300 | Grid | Maintenance | UFM |
544 | Daily Report Mail Sent Failed | 1 | 0 | Minor | 1 | 300 | Grid | Maintenance | UFM |
545 | SM is not responding | 1 | 1 | Critical | 1 | 300 | Grid | Maintenance | UFM |
560 | User Connected | Security | UFM | ||||||
561 | User Disconnected | Security | UFM | ||||||
602 | UFM Server Failover | 1 | 1 | Critical | 1 | 0 | Site | Fabric Notification | UFM |
603 | Events Suppression | 1 | 0 | Critical | 0 | 300 | Site | Maintenance | UFM |
604 | Report Succeeded | 1 | 1 | Info | 1 | 300 | Grid | Maintenance | UFM |
605 | Report Failed | 1 | 1 | Critical | 1 | 300 | Grid | Maintenance | UFM |
606 | Correction Attempts Paused | 1 | 0 | Warning | 1 | 0 | Site | Fabric Notification | UFM |
701 | Non-optimal Link Speed | 1 | 1 | Minor | 1 | 0 | Port | Hardware | UFM |
702 | Unhealthy IB Port | 1 | 1 | Warning | 1 | 0 | Port | Hardware | SM |
703 | Fabric Collector Connected | 1 | 0 | Info | 1 | 0 | Grid | Maintenance | UFM |
704 | Fabric Collector Disconnected | 1 | 1 | Critical | 1 | 0 | Grid | Maintenance | UFM |
750 | High data retransmission count on port | 1 | 1 | Warning | 500 | 1 | Port | Hardware | SM |
901 | Fabric Configuration Started | 0 | 1 | Info | 1 | 0 | Grid | Fabric Notification | UFM |
902 | Fabric Configuration Completed | 0 | 1 | Info | 1 | 0 | Grid | Fabric Notification | UFM |
903 | Fabric Configuration Failed | 0 | 1 | Critical | 1 | 0 | Grid | Fabric Notification | UFM |
904 | Device Configuration Failure | 0 | 1 | Critical | 1 | 0 | Device | Fabric Notification | UFM |
905 | Device Configuration Timeout | 0 | 1 | Critical | 1 | 0 | Device | Fabric Notification | UFM |
906 | Provisioning Validation Failure | 0 | 1 | Critical | 1 | 0 | Grid | Fabric Notification | UFM |
907 | Switch is Down | 1 | 1 | Critical | 1 | 0 | Site | Fabric Topology | UFM |
908 | Switch is Up | 1 | 1 | Info | 1 | 300 | Site | Fabric Topology | UFM |
909 | Director Switch is Down | 1 | 1 | Critical | 1 | 300 | Site | Fabric Topology | UFM |
910 | Director Switch is Up | 1 | 1 | Info | 1 | 0 | Site | Fabric Topology | UFM |
911 | Module Temperature Low Threshold Reached | 1 | 1 | Warning | 60 | 300 | Module | Hardware | Telemetry |
912 | Module Temperature High Threshold Reached | 1 | 1 | Critical | 60 | 300 | Module | Hardware | Telemetry |
913 | Module High Voltage | 1 | 1 | Warning | 10 | 420 | Switch | Module Status | Telemetry |
914 | Module High Current | 1 | 1 | Warning | 10 | 420 | Switch | Module Status | Telemetry |
915 | BER_ERROR | 1 | 1 | Critical | 1e-8 | 420 | Port | Hardware | Telemetry |
916 | BER_WARNING | 1 | 1 | Warning | 1e-13 | 420 | Port | Hardware | Telemetry |
917 | SYMBOL_BER_ERROR | 1 | 1 | Critical | 10 | 420 | Port | Hardware | Telemetry |
918 | High Symbol BER reported | 1 | 1 | Warning | 10 | 420 | Port | Hardware | Telemetry |
919 | Cable Temperature High | 1 | 1 | Critical | 0 | 0 | Port | Hardware | Telemetry |
920 | Cable Temperature Low | 1 | 1 | Critical | 0 | 0 | Port | Hardware | Telemetry |
1300 | SM_SAKEY_VIOLATION | 1 | 1 | Warning | 5300 | Port | Security | SM | |
1301 | SM_SGID_SPOOFED | 1 | 1 | Warning | 5300 | Port | Security | SM | |
1302 | SM_RATE_LIMIT_EXCEEDED | 1 | 1 | Warning | 5300 | Port | Security | SM | |
1303 | SM_MULTICAST_GROUPS_LIMIT_EXCEEDED | 1 | 1 | Warning | 5300 | Port | Security | SM | |
1304 | SM_SERVICES_LIMIT_EXCEEDED | 1 | 1 | Warning | 5300 | Port | Security | SM | |
1305 | SM_EVENT_SUBSCRIPTION_LIMIT_EXCEEDED | 1 | 1 | Warning | 5300 | Port | Security | SM | |
1306 | Unallowed SM was detected in the fabric | 1 | 1 | Warning | 0 | 300 | Port | Fabric Notification | SM |
1307 | SMInfo SET request was received from unallowed SM | 1 | 1 | Warning | 0 | 300 | Port | Fabric Notification | SM |
1309 | SM was detected with non-matching SMKey | 1 | 1 | Warning | 0 | 300 | Port | Fabric Notification | SM |
1310 | Duplicated node GUID was detected | 1 | 1 | Critical | 1 | 0 | Device | Fabric Notification | SM |
1311 | Duplicated port GUID was detected | 1 | 1 | Critical | 1 | 0 | Port | Fabric Notification | SM |
1312 | Switch was Rebooted | 1 | 1 | Info | 1 | 0 | Device | Fabric Notification | UFM |
1315 | Topo Config File Error | 1 | 1 | Critical | 1 | 0 | Grid | Fabric Notification | UFM |
1316 | Topo Config Subnet Mismatch | 1 | 1 | Critical | 1 | 0 | Grid | Fabric Notification | Topodiff |
1400 | High Ambient Temperature | 1 | 1 | Warning | 0 | 86400 | Switch | Hardware | Switch |
1401 | High Fluid Temperature | 1 | 1 | Warning | 0 | 86400 | Switch | Hardware | Switch |
1402 | Low Fluid Level | 1 | 1 | Warning | 0 | 86400 | Switch | Hardware | Switch |
1403 | Low Supply Pressure | 1 | 1 | Warning | 0 | 86400 | Switch | Hardware | Switch |
1404 | High Supply Pressure | 1 | 1 | Warning | 0 | 86400 | Switch | Hardware | Switch |
1405 | Low Return Pressure | 1 | 1 | Warning | 0 | 86400 | Switch | Hardware | Switch |
1406 | High Return Pressure | 1 | 1 | Warning | 0 | 86400 | Switch | Hardware | Switch |
1407 | High Differential Pressure | 1 | 1 | Warning | 0 | 86400 | Switch | Hardware | Switch |
1408 | Low Differential Pressure | 1 | 1 | Warning | 0 | 86400 | Switch | Hardware | Switch |
1409 | System Fail Safe | 1 | 1 | Warning | 0 | 86400 | Switch | Hardware | Switch |
1410 | Fault Critical | 1 | 1 | Critical | 0 | 86400 | Switch | Hardware | Switch |
1411 | Fault Pump1 | 1 | 1 | Critical | 0 | 86400 | Switch | Hardware | Switch |
1412 | Fault Pump2 | 1 | 1 | Critical | 0 | 86400 | Switch | Hardware | Switch |
1413 | Fault Fluid Level Critical | 1 | 1 | Critical | 0 | 86400 | Switch | Hardware | Switch |
1414 | Fault Fluid Over Temperature | 1 | 1 | Critical | 0 | 86400 | Switch | Hardware | Switch |
1415 | Fault Primary DC | 1 | 1 | Critical | 0 | 86400 | Switch | Hardware | Switch |
1416 | Fault Redundant DC | 1 | 1 | Critical | 0 | 86400 | Switch | Hardware | Switch |
1417 | Fault Fluid Leak | 1 | 1 | Critical | 0 | 86400 | Switch | Hardware | Switch |
1418 | Fault Sensor Failure | 1 | 1 | Critical | 0 | 86400 | Switch | Hardware | Switch |
1419 | Cooling Device Monitoring Error | 1 | 0 | Critical | 0 | 1 | Grid | Hardware | Switch |
1420 | Cooling Device Communication Error | 1 | 1 | Critical | 0 | 86400 | Switch | Hardware | Switch |
1500 | New cable detected | 1 | 0 | Info | 1 | 0 | Link | Security | UFM |
1502 | Cable detected in a new location | 1 | 0 | Warning | 1 | 0 | Link | Security | UFM |
1503 | Duplicate Cable Detected | 1 | 0 | Critical | 1 | 0 | Link | Security | UFM |
1315 | Topo Config File Error | 1 | 1 | Critical | 1 | 0 | Grid | Fabric Notification | UFM |
1504 | SHARP Allocation Succeeded | 1 | 1 | Info | 1 | 0 | Grid | SHARP | SHARP |
1505 | SHARP Allocation Failed | 1 | 0 | Warning | 1 | 0 | Grid | SHARP | SHARP |
1506 | SHARP Deallocation Succeeded | 1 | 0 | Info | 1 | 0 | Grid | SHARP | SHARP |
1507 | SHARP Deallocation Failed | 1 | 0 | Warning | 1 | 0 | Grid | SHARP | SHARP |
1508 | Device Collect System Dump Started | 1 | 0 | Info | 1 | 300 | Device | Maintenance | UFM |
1509 | Device Collect System Dump Finished | 1 | 0 | Info | 1 | 300 | Device | Maintenance | UFM |
1510 | Device Collect System Dump Error | 1 | 0 | Critical | 1 | 300 | Device | Maintenance | UFM |
1511 | Virtual Port Added | 1 | 0 | Info | 1 | 0 | Port | Fabric Notification | SM |
1512 | Virtual Port Removed | 1 | 0 | Warning | 1 | 0 | Port | Fabric Notification | SM |
1513 | Burn Cables Transceivers Started | 1 | 0 | Info | 1 | 0 | Device | Maintenance | UFM |
1514 | Burn Cables Transceivers Finished | 1 | 0 | Info | 1 | 0 | Device | Maintenance | UFM |
1515 | Burn Cables Transceivers Failed | 1 | 0 | Warning | 1 | 0 | Device | Maintenance | UFM |
1516 | Activate Cables Transceivers FW Finished | 1 | 0 | Info | 1 | 0 | Device | Maintenance | UFM |
1517 | Activate Cables Transceivers FW Failed | 1 | 0 | Warning | 1 | 0 | Device | Maintenance | UFM |
1520 | Aggregation Node Discovery Failed | 1 | 0 | Critical | 1 | 0 | SHARP AM | SHARP | SHARP |
1521 | Job Started | 1 | 0 | Info | 1 | 0 | SHARP AM | SHARP | SHARP |
1522 | Job Ended | 1 | 0 | Info | 1 | 0 | SHARP AM | SHARP | SHARP |
1523 | Job Start Failed | 1 | 0 | Critical | 1 | 0 | SHARP AM | SHARP | SHARP |
1524 | Job Error | 1 | 0 | Critical | 1 | 0 | SHARP AM | SHARP | SHARP |
1525 | Trap QP Error | 1 | 0 | Critical | 1 | 0 | SHARP AM | SHARP | SHARP |
1526 | Trap Invalid Request | 1 | 0 | Critical | 1 | 0 | SHARP AM | SHARP | SHARP |
1527 | Trap Sharp Error | 1 | 0 | Critical | 1 | 0 | SHARP AM | SHARP | SHARP |
1528 | Trap QP Alloc timeout | 1 | 0 | Critical | 1 | 0 | SHARP AM | SHARP | SHARP |
1529 | Trap AMKey Violation | 1 | 0 | Critical | 1 | 0 | SHARP AM | SHARP | SHARP |
1530 | Unsupported Trap | 1 | 0 | Critical | 1 | 0 | SHARP AM | SHARP | SHARP |
1531 | Reservation Updated | 1 | 0 | Info | 1 | 0 | SHARP AM | SHARP | SHARP |
1532 | Sharp is not Responding | 1 | 0 | Critical | 1 | 0 | SHARP AM | SHARP | SHARP |
1533 | Agg Node Active | 1 | 0 | Info | 1 | 0 | SHARP AM | SHARP | SHARP |
1534 | Agg Node Inactive | 1 | 0 | Warning | 1 | 0 | SHARP AM | SHARP | SHARP |
1535 | Trap AMKey Violation Triggered by AM | 1 | 0 | Warning | 1 | 0 | SHARP AM | SHARP | SHARP |
1550 | Guids Were Added to Pkey | 1 | 0 | Info | 1 | 0 | Port | Fabric Notification | UFM |
1551 | Guids Were Removed from Pkey | 1 | 0 | Info | 1 | 0 | Port | Fabric Notification | UFM |
1600 | VS/CC Classes Key Violation | Security | SM | ||||||
1602 | PCI Speed Degradation Warning | 1 | 1 | Warning | 1 | 0 | Port | Fabric Notification | UFM |
1603 | PCI Width Degradation Warning | 1 | 1 | Warning | 1 | 0 | Port | Fabric Notification | UFM |