Adding Support for New RMS Hardware

View as Markdown

This guide explains how to add or extend hardware support in the Rack Management Service (RMS) stack when new BMC/server hardware arrives that does not work out of the box.

For the list of currently supported hardware, see RMS Hardware Compatibility List.

Overview

RMS models hardware as a closed set of concrete node types. A new platform is not only a new Redfish or NVUE behavior; it usually affects API identity, endpoint policy, rack-family routing, concrete node construction, firmware activation policy, firmware-object mapping, and tests.

The most important rule is to keep existing hardware behavior stable. Add a new NodeType or a narrow wrapper when behavior differs by product, vendor, or firmware package policy. Do not silently change shared GB200 or GB300 behavior unless the change is valid for every node type that delegates to that code.

Implementation Patterns

RMS hardware support generally follows three common patterns:

PatternExampleWhen to Use
Explicit hardware identityComputeGb200Nvidia, SwitchGb200Nvidia, PowershelfGb200LiteonUse when a previously generic role needs a stable product/vendor-specific API value.
Thin wrapper over an existing implementationSwitchGb300Nvidia, PowershelfGb300Liteon, NvidiaGb300ComputeUse when the new hardware shares most behavior with an existing node but needs a distinct NodeType, product family, or NVFWUPD server type.
Wrapper with targeted overridesLenovoGb300Compute, PowershelfGb300DeltaUse when most behavior can be reused but the platform needs vendor-specific firmware options, preserve-config behavior, endpoint discovery, power control, or component filtering.

Before Coding

Classify the new hardware before making code changes:

  1. Is it a new product family, such as a new NVL rack generation?
  2. Is it a new node role, or one of the existing roles: compute, powershelf, or switch?
  3. Is it a new vendor-specific node type inside an existing product family?
  4. Does it use the BMC endpoint, the host endpoint, or both?
  5. Does NVFWUPD already have an appropriate ServerType, target class, and firmware package behavior?
  6. Does firmware-object apply need target remapping, component filtering, or multiple firmware packages for one logical target?
  7. Can it safely delegate to an existing implementation, or does it need a new concrete node implementation?

API and Node Identity

Unless stated otherwise, paths in this guide are relative to crates/rackmanagementservice.

Add or update the public node identity first. RMS uses the protobuf NodeType as the API contract and src/domain/node.rs as the domain source of truth.

Expected changes:

  • Update the NodeType enum in the nv-rms-client protobuf/client source, then bump the src/api/grpc/proto/nv-rms-client submodule pointer in RMS.
  • Add the matching domain variant in src/domain/node.rs.
  • Add the stable config string in NodeType::as_str().
  • Add the role in NodeType::kind().
  • Add the rack generation in NodeType::product_family().
  • Confirm NodeType::uses_host_management_endpoint() is correct. Switches use the host endpoint; compute and powershelf nodes normally use the BMC endpoint.
  • Add or reuse the right NvfwupdServerProfile in NodeType::nvfwupd_server_profile().
  • Extend the NodeType metadata tests in src/domain/node.rs.

If the hardware belongs to a new rack generation, add a new ProductFamily value and define its rack type and model strings.

Concrete Node Implementation

Add a concrete node module under src/nodes/ when the new hardware needs a distinct runtime implementation. Start with the smallest implementation that preserves a distinct NodeType.

Expected changes:

  • Add a module in src/nodes/mod.rs.
  • Add a concrete node type file, for example compute_<family>_<vendor>.rs.
  • Implement from_config() and reject mismatched config.node_type.
  • Implement the Node trait.
  • Return the new NodeType from node_type().
  • Override get_info() so the returned type field uses the new stable node type string.
  • Validate required endpoints. BMC-backed nodes should reject missing BMC endpoints; switch nodes should validate host endpoint behavior.
  • Delegate to an existing implementation only when its behavior is correct for the new hardware.
  • Add unit tests for constructor validation, reported node type, endpoint handling, and any vendor-specific behavior.

Thin wrappers are preferred when behavior is intentionally shared. For example, GB300 switch support can alias the GB200 switch implementation while preserving the GB300 node type so NVFWUPD and API routing select GB300 behavior where needed.

Use targeted overrides when only a few operations differ. Lenovo GB300 compute delegates most behavior to NVIDIA GB300 compute, but overrides firmware update options for Lenovo BMC and HGX targets and preserves Lenovo BMC update configuration before BMC updates.

Runtime Dispatch

Register the new node type in src/nodes/instance.rs. This is the bridge between the domain NodeType and the concrete runtime implementation.

Expected changes:

  • Add a NodeInstance enum variant.
  • Add the variant to the match_node_instance! macro.
  • Add construction in NodeInstance::from_config().
  • Add switch-specific trait dispatch if the node is a switch: SwitchFirmwareManagement, SwitchPasswordManagement, SwitchScaleUpManagement, and device-info behavior.
  • Add compute or switch device-info handling in NodeInstance::get_device_info() if the new node exposes topology or chassis-location data.

Because NodeInstance is intentionally closed and exhaustive, missing entries usually appear as compile errors. Treat those compile errors as useful checklist items, not as noise.

Rack and Product-Family Routing

RMS rejects nodes whose product family does not match the rack type. For a new node type, verify that rack creation and node admission agree.

Expected changes:

  • For an existing rack family, update NodeType::product_family().
  • For a new rack family, add a rack wrapper in src/racks/ and export it from src/racks/mod.rs.
  • Update create_rack_by_type() in src/orchestrator/rack_manager.rs.
  • Add tests that create the new rack type and reject the new node type in the wrong rack family.

When a later rack generation shares behavior with an existing family, prefer an inner wrapper that preserves the shared implementation while changing the rack type and model strings. This keeps the product-family identity distinct without duplicating rack behavior.

gRPC Conversion and Endpoint Policy

Update src/api/grpc/conversions.rs whenever a new protobuf node type is introduced.

Expected changes:

  • Map protobuf NodeType to the domain NodeType.
  • Map domain NodeType back to protobuf.
  • Confirm proto_node_type_to_string() returns the stable node type name.
  • Add tests for both conversion directions.
  • Confirm flattened endpoint handling still selects BMC or host endpoint based on the new node type.

Most endpoint behavior should follow NodeType::uses_host_management_endpoint(). If a handler still has explicit node-type matching, update it intentionally and add a regression test.

Firmware and NVFWUPD

Firmware support is usually the widest part of a new hardware change. RMS has two layers to update: the concrete node implementation and the firmware-object apply path.

Expected changes in RMS:

  • Update src/nodes/nvfwupd_adapter.rs if the new node needs a new NvfwupdServerProfile or a different NVFWUPD ServerType.
  • Implement or delegate node methods for inventory, version checks, update, task polling, and activation.
  • Update activation_mode_for_node() in src/api/grpc/firmware_handlers.rs.
  • Update node_supports_post_activation_version_check() when post-activation version verification applies.
  • Update firmware-object lookup tables and mappings in src/api/grpc/firmware_object_handlers.rs.
  • Add component policy for vendor-specific firmware targets, such as BMC-only, HMC-only, LiteOn PSU/PMC, or Delta PSU/PMC.
  • Add multi-package rules when one logical target needs more than one firmware package.

Expected changes in NVFWUPD:

The following NVFWUPD paths are relative to crates/rust_nvfwupd.

  • Confirm src/workflow.rs has the correct ServerType.
  • Add target aliases in src/rf_target.rs if package metadata or CLI input needs to resolve to an existing target implementation.
  • Add or update target behavior in src/workflow_api.rs when the activation, update, or version-check workflow differs.
  • Add tests for server-type mapping, package parsing, update request options, and activation behavior.

Use vendor-specific firmware options only in the wrapper for that vendor. For example, Lenovo GB300 sets OEM parameters for BMC and HGX targets without changing the shared GB300 compute behavior.

Handler Surfaces to Review

After adding the domain node type and concrete node, search for existing explicit NodeType matches. Use this tree as the quick review map:

crates/
├── rackmanagementservice/
│ ├── src/
│ │ ├── domain/
│ │ │ └── node.rs # NodeType, NodeKind, ProductFamily, endpoint policy
│ │ ├── nodes/
│ │ │ ├── instance.rs # NodeInstance construction and trait dispatch
│ │ │ ├── mod.rs # Node module exports
│ │ │ ├── compute_<family>_<vendor>.rs # Compute implementations and wrappers
│ │ │ ├── switch_<family>_<vendor>.rs # Switch implementations and wrappers
│ │ │ ├── powershelf_<family>_<vendor>.rs # Powershelf implementations and wrappers
│ │ │ └── nvfwupd_adapter.rs # NVFWUPD profile to ServerType mapping
│ │ ├── racks/
│ │ │ ├── mod.rs # Rack module exports
│ │ │ └── nvl_gb.rs # NVL GB rack wrappers and product-family checks
│ │ ├── orchestrator/
│ │ │ └── rack_manager.rs # Rack creation and node admission
│ │ └── api/grpc/
│ │ ├── conversions.rs # Protobuf/domain NodeType mapping and endpoints
│ │ ├── inventory_handlers.rs # Inventory and device-info APIs
│ │ ├── power_handlers.rs # Power state and power actions
│ │ ├── firmware_handlers.rs # Firmware upload, activation, and batch update
│ │ ├── firmware_object_handlers.rs # Firmware-object target/component mapping
│ │ ├── switch_handlers.rs # Switch management flows
│ │ ├── switch_image_handlers.rs # Switch image management
│ │ ├── switch_security_handlers.rs # Switch security and credential flows
│ │ ├── switch_certificate_handlers.rs # Switch certificate flows
│ │ ├── scaleupfabricmanager_handlers.rs # Scale-up FM flows
│ │ ├── node_recovery.rs # Node recovery flows
│ │ └── proto/nv-rms-client/ # Protobuf/client NodeType source
│ └── tests/
│ ├── client/src/main.rs # Admin/test client node-type parsing
│ └── grpc_e2e.rs # End-to-end API coverage
└── rust_nvfwupd/
└── src/
├── workflow.rs # NVFWUPD ServerType definitions
├── workflow_api.rs # Update, activation, and version workflows
└── rf_target.rs # Firmware target aliases and parsing

Prefer role-based checks through NodeKind when all nodes in a role should behave the same. Use explicit node-type checks only when behavior really differs by hardware type or vendor.

Testing

At minimum, add unit tests for the files touched by the new hardware path:

  • src/domain/node.rs: string, kind, product family, endpoint policy, and NVFWUPD profile.
  • src/api/grpc/conversions.rs: protobuf/domain round trips and stable string conversion.
  • src/nodes/<new_node>.rs: constructor validation, reported type, endpoint requirements, and platform-specific overrides.
  • src/nodes/instance.rs: construction and dispatch when the new node has special switch or device-info behavior.
  • src/orchestrator/rack_manager.rs or src/racks/*: rack creation and product-family mismatch checks.
  • src/api/grpc/firmware_handlers.rs: activation mode and post-activation version-check policy.
  • src/api/grpc/firmware_object_handlers.rs: firmware-object device type, component filtering, multi-package rules, and target mapping.
  • tests/client/src/main.rs: node-type parsing and role-specific client behavior.
  • tests/grpc_e2e.rs: one end-to-end API path for create/add/list/power or firmware behavior.

For vendor quirks, use focused HTTP mock tests to verify preserve-configuration PATCH behavior, readback verification, retry behavior, and firmware update option selection.

For real hardware validation, run a small progression before broad rollout:

  1. Create a rack of the target product family.
  2. Add one node with the new NodeType and the expected endpoint shape.
  3. List inventory and confirm the returned node type.
  4. Run a low-risk power read.
  5. Run firmware inventory.
  6. Verify firmware package versions for a known-good package.
  7. Exercise the narrowest safe firmware update or activation flow in a controlled lab.

Documentation and Release Checklist

Update documentation with the same branch as the hardware support code:

  • Add the new platform to the Hardware Compatibility List when support is ready.
  • Add it under “Hardware Under Development” while support is still being validated.
  • Document required rack profile values for NICo integration, especially product family and canonical vendor strings.