Problem IndicatorSymptomsCause and Solution
LEDsSystem Status LED is blinking for more than 5 minutesCause: MLNX-OS software did not boot properly and only firmware is running.

Solution: Connect to the system via the console port, and check the software status. You might need to contact an FAE if the MLNX-OS software did not load properly.

System Status LED is amber

Cause:

  • Critical system fault (CPU error, bad firmware)
  • Over temperature

Solution:

  • Check environmental conditions (room temperature)
Fan Status LED is amberCause: Possible fan issue
Solution:
  • Check that the fan is fully inserted and nothing blocks the airflow
  • Replace the fan FRU if needed
Front PSU Status LED is amber

Cause: Possible PSU issue
Solution:

  • Check/replace the power cable
  • Replace the PSU if needed
The activity LED does not light up (InfiniBand)Make sure that there is an SM running in the fabric.
System boot failureThe last software upgrade failed on x86 based systems

Solution:

  • Connect the RS232 connector (CONSOLE) to a laptop.
  • Push the system’s reset button.
  • Press the ArrowUp or ArrowDown key during the system boot. GRUB menu will appear. For example:
Default image: 'SX_X86_64 SX_3.4.0008 2014-11-10 20:07:51 x86_64'
Press enter to boot this image, or any other key for boot menu
Booting default image in 3 seconds.
Boot Menu
-------------------------------------------------------------------
0: SX_X86_64 SX_3.4.0008 2014-11-10 20:07:51 x86_64
1: SX_X86_64 SX_3.4.0007 2014-10-23 17:27:34 x86_64
-------------------------------------------------------------------
Use the ArrowUp and ArrowDown keys to select which entry is highlighted.
Press enter to boot the selected image or 'p' to enter a password to unlock the next set of features.
Highlighted entry is 0:
"
  • Select previous image to boot by pressing an arrow key and choosing the appropriate image.