mlxlink Utility
The mlxlink tool is used to check and debug link status and related issues. The tool can be used on different links and cables (passive, active, transceiver and backplane).
In order for mlxlink to function properly, make sure to update the firmware version to the latest version.
mlxlink is intended for advanced users with appropriate technical background.
Do not use mlxlink to disable the port connecting between the host and the unmanaged switch using (“--port_state dn”) flag.
mlxlink errors, warnings and notes are printed on stderr console.
Setting the speeds (50GbE, 100GbE and 200GbE) for the new devices (NVIDIA ConnectX-6 and above, NVIDIA Quantum switches and above) requires specifying the number of lanes for the speed: mlxlink -d <dev> --speeds [50G_2X | 50G_1X | 100G_2X | 100G_4X | 200G_4X ].
In ConnectX-7 and later cards, configuring the loopback can be applied when the link is fully down (not in polling state).
To run mlxlink:
mlxlink [OPTIONS]
where:
Options:
-h |--help |
Display help message. |
-v |--version |
Display version info. |
-d |--device <device> |
Perform operation for a specified mst device |
-p |--port <port_number> |
Port Number |
--port_type <port_type> |
Port Type [NETWORK(Default)/PCIE/OOB] |
--depth <depth> |
Depth level of the DUT of some hierarchy (valid for PCIe port type only) |
--pcie_index <pcie_index> |
PCIe index number (Internal domain index) (valid for PCIe port type only) |
--node <node> |
The node within each depth (valid for PCIe port type only) |
--json |
Print the output in JSON format |
Queries:
--show_links |
Show valid PCIe links (valid for PCIe port type only) |
-m |--show_module |
Show Module Info |
-c |--show_counters |
Show Physical Counters and BER Info |
-e |--show_eye |
Show Eye Opening Info |
--show_fec |
Show FEC Capabilities |
--show_serdes_tx |
Show Transmitter Info |
--show_tx_group_map <group_num> |
Display all label ports mapped to group <group_num> (for NVIDIA Spectrum-2 and NVIDIA Quantum devices). |
--show_device |
General Device Info |
--show_ber_monitor |
Show BER Monitor Info. Note: The flag is not supported in HCAs. |
--show_external_phy |
Show External PHY Info Note: The flag is supported in NVIDIA Spectrum switch systems only. |
Commands:
-a |--port_state <port_state> |
Configure Port State [UP(up)/DN(down)/TG(toggle)] |
|||
-s |--speeds <speeds> |
Configure Speeds [speed1,speed2,...] |
|||
--link_mode_force |
Configure Link Mode Force (Disable AN) |
|||
-l |--loopback <loopback> |
Configure Loopback Mode [NO(no loopback)/RM(phy remote Rx-to-Tx loopback)/PH(internal phy Tx-to-Rx loopback)/EX(external loopback connector needed)/LL(link layer local loopback)] |
|||
-k |--fec <fec_override> |
Configure FEC [AU(Auto)/NF(No-FEC)/FC(FireCode FEC)/ RS(RS-FEC)]/LL(LL-RS-FEC)/DF-RS(Interleaved_RS-FEC)/DF-LL(Interleaved_LL_RS-FEC)] |
|||
--fec_speed <fec_speed> |
Speed to Configure FEC [100G/50G/25G/...] (Default is Active Speed) |
|||
--serdes_tx <params> |
Configure Transmitter Parameters [polarity,ob_tap0,...] |
|||
--serdes_tx_lane <transmitter_lane> |
Transmitter Lane to Set (Optional - Default All Lanes) |
|||
--database |
Save Transmitter Configuration for Current Speed Permanently (Optional) |
|||
--tx_params_override |
Set the parameters according to Data Base only, otherwise it will be set according to the best possible configuration chosen by the system (e.g. KR-startup) (Optional) |
|||
--tx_group_map <group_num> |
Map ports to group <group_num> (for NVIDIA Spectrum-2 and NVIDIA Quantum devices) |
|||
--ports <ports> |
Ports to be mapped [1,2,3,4..] |
|||
--test_mode <prbs_mode> |
Physical Test Mode Configuration [EN(enable)/DS(disable)/TU(perform tuning)] |
|||
--rx_prbs <rx_prbs_mode> |
RX PRBS Mode [PRBS31(Default)/PRBS7/...] (Optional - Default PRBS31) |
|||
--tx_prbs <tx_prbs_mode> |
TX PRBS Mode [PRBS31(Default)/PRBS7/...] (Optional - Default PRBS31) |
|||
--rx_rate <rx_lane_rate> |
RX Lane Rate [EDR(Default)/25G/10G/...] (Optional - Default 25G) |
|||
--tx_rate <tx_lane_rate> |
TX Lane Rate [EDR(Default)/25G/10G/...] (Optional - Default 25G) |
|||
--invert_tx_polarity |
PRBS TX polarity inversion (Optional - Default No Inversion) |
|||
--invert_rx_polarity |
PRBS RX polarity inversion (Optional - Default No Inversion) |
|||
--lanes |
PRBS lanes to set (one or more lane separated by comma)[0,1,2,...] Optional: Default all lanes |
|||
-b |--ber_collect <csv_file> |
Port Extended Information Collection [CSV File] |
|||
--amber_collect <csv_file> |
AmBER Port Extended Information Collection For 16nm Products and Later [CSV File] |
|||
--ber_limit <limit_criteria> |
BER Limit Criteria [Nominal(Default)/Corner/Drift] (Optional - Default Nominal) |
|||
--iteration <iteration> |
Iteration Number of BER Collection |
|||
--pc |
Clear Counters |
|||
--set_external_phy |
Set External PHY Note: The flag is supported in NVIDIA Spectrum switch systems only. |
|||
--twisted_pair_force_mode <twisted_pair_force_mode> |
Twisted Pair Force Mode [MA(Master)/SL(Slave)] |
|||
--cable |
Perform operations on the cables |
|||
--dump |
Dump cable pages in raw format |
|||
--ddm |
Get cable Digital Diagnostic Monitoring information |
|||
--read |
Perform read operation from specific page |
|||
--length <length> |
Length of data to read in bytes (Optional - Default 1 byte) |
|||
--page <pageNum> |
Specific page number to read/write |
|||
--offset <offset> |
Specific page offset to read/write |
|||
--write <bytes> |
Perform write operation with specific data (list of bytes, separated by ',') |
|||
--prbs_select <side> |
Module PRBS test mode side selector [MEDIA, HOST] |
|||
--prbs_mode <cmd> |
Perform PRBS test mode on the Module [EN(Enable),DS(Disable)] |
|||
--generator_pattern <pattern> |
Set PRBS generator pattern [PRBS31(default),PRBS23,PRBS7,PRBS11,PRBS9,PRBS13,SSPR,SSPRQ] |
|||
--swap_generator |
Enable PAM4 MSB <-> LSB generator swapping (Optional) |
|||
--invert_generator |
Enable PRBS generator inversion (Optional) |
|||
--generator_lanes <lanes> |
PRBS generator lanes to set (one or more lane separated by comma)[0,1,2,3,4,5,6,7] (Optional - Default all lanes) |
|||
--checker_pattern <pattern> |
Set PRBS checker pattern [PRBS31(default),PRBS23,PRBS7,PRBS11,PRBS9,PRBS13,SSPR,SSPRQ] |
|||
--swap_checker |
Enable PAM4 MSB <-> LSB checker swapping (Optional) |
|||
--invert_checker |
Enable PRBS checker inversion (Optional) |
|||
--checker_lanes <lanes> |
PRBS checker lanes to set (one or more lane separated by comma)[0,1,2,3,4,5,6,7] (Optional - Default all lanes) |
|||
--lane_rate <rate> |
Set PRBS checker and generator lane rate [HDR(50G)(default),1.25G,SDR(2.5G),10.3125G,FDR(14G),EDR(25G),NDR(100G)] |
|||
--show_diagnostic_info |
Show PRBS diagnostic counters information |
|||
--clear_diagnostic_info |
Clear PRBS diagnostic counters |
|||
--control_parameters |
Show Module Control Parameters |
|||
--tx_equalization <value> |
Set Module Tx Input Equalization in dB [NE(No Equalization),1,2,3,4,5,6,7,8, 9,10,11,12] |
|||
--rx_emphasis <value> |
Set Module RX Output Emphasis in dB. for CMIS, pre-emphasis value will be set [NE(No Equalization),0.5,1,1.5,2,2.5,3,3.5,4,5,6,7] |
|||
--rx_post_emphasis <value> |
Set Module Rx Post Emphasis in dB [NE(No Equalization),1,2,3,4,5,6,7] |
|||
--rx_amplitude <value> |
Set Module Rx Output Amplitude [0(100-400mV),1(300-600mV),2(400-800mV),3(600-1200mV)] |
|||
--margin |
Read the SerDes eye margins per lane |
|||
--measure_time <time> |
Measure time in seconds for single eye [10, 30, 60, 90, 120, 240, 480, 600 and 900] (Optional - Default 60 for PCIe and 30 for Network ports) |
|||
--eye_select <eye_sel> |
Eye selection for PAM4 [UP, MID, DOWN, ALL] (Default ALL) |
|||
--lane <lane_index> |
Run eye for specific lane index (Default all lanes) |
|||
--rx_error_injection |
Enable the RX link deterioration |
|||
--mixer_offset0 <value> |
Fine change to the center of the eye [0x0 to 0x7ff] |
|||
--mixer_offset1 <value> |
Coarse change to the center of the eye [0x0 to 0x3ff] |
|||
--show_mixers_offset |
Show mixer offset 0 and mixer offset 1 |
|||
--rx_fec_histogram |
Provide histogram of FEC errors. The result is divided to bins. Each bin is holding different number of errored bit within FEC protected block |
|||
--show_histogram |
Show FEC errors histogram |
|||
--clear_histogram |
Clears FEC errors histograms |
|||
--pcie_error_injection |
Start/show PCIe error injection |
|||
--error_type <type> |
PCIe error type [ABORT(0),BAD_DLLP_LCRC(1),BAD_TLP_LCRC(2),BAD_TLP_ECRC(3),ERR_MSG(4),MALFORMED_TLP(5),POISONED_TLP(6),UNEXPECTED_CPL(7),ACS_VIOLATION(8),SURPRISE_LINK_DOWN(100),RECEIVER_ERROR(101)] |
|||
--error_duration <duration> |
Error duration, depend on the error type |
|||
--injection_delay <delay> |
Delay in micro-seconds before applying the error (Optional) |
|||
--error_parameters <params> |
Comma-separated parameters for selected error type (param0,param1,param2,param3) |
|||
--dbdf <dbdf> |
Destination bus device function, e.g af:00.0 (Optional used for specific error type) |
|||
--yes |
Non-interactive mode, answer yes to all questions |
Examples:
Get info of <device>, <port_number>:
mlxlink -d <device> -p <port_number>
Get info of <device>, <port_number> and BER Counters:
mlxlink -d <device> -p <port_number> -c
Get info of <device>, <port_number> and Transmitter Parameters:
mlxlink -d <device> -p <port_number> --show_serdes_tx
Configure Port State:
mlxlink -d <device> -p <port_number> --port_state UP
Configure Port Speeds:
mlxlink -d <device> -p <port_number> --speeds 25G,50G,100G
Configure FEC:
mlxlink -d <device> -p <port_number> --fec RS
Configure Port for Physical Test Mode:
mlxlink -d <device> -p <port_number> --test_mode EN (--rx_prbs PRBS31 --rx_rate 25G --tx_prbs PRBS7 --tx_rate 10G --invert_rx_polarity --invert_tx_polarity)
Perform PRBS Tuning:
mlxlink -d <device> -p <port_number> --test_mode TU
RX and TX lane rates for new devices include the PAM4 speeds (50G_1X and 100G_2X).
eg: mlxlink -d <device> --test_mode EN --rx_rate [normal speeds | 50G_1X | 100G_2X] --tx_rate [normal speeds | 50G_1X | 100G_2X]
The PRBS pattern configured in PAM4 rates is PRBSQ.
Cable operations:
mlxlink -d <device> --cable [Options]
Dump cable EEPROM pages:
mlxlink -d <device> --cable --dump
Get cable DDM information:
mlxlink -d <device> --cable --ddm
Read from cable:
mlxlink -d <device> --cable --read --page <page number> --offset <bytes offset> --length <number of bytes>
Write to cable:
mlxlink -d <device> --cable --write <bytes separated by comma> --page <page number> --offset <bytes offset>
Configure Transmitter Parameters (on lane, to database):
mlxlink -d <device> -p <port_number> --serdes_tx <polar- ity>,<ob_tap0>,<ob_tap1>,<ob_tap2>,<ob_bias>,<ob_preemp_mode>,<ob_reg>,<ob_leva> (--serdes_tx_lane <lane number>) (--database)
Configure Transmitter Parameters for 16nm devices:
mlxlink -d <device> -p <port_number> --serdes_tx <pre_2_tap>,<pre_tap>,<main_tap>,<post_tap>,<ob_m2lp>,<ob_amp>
Getting PCIe links info:
mlxlink -d /dev/mst/mt41682_pciconf0 --port_type PCIE --show_links
Valid PCIe Links
----------------
: depth, pcie_index, node, port
Link 1
: 3
, 0
, 0
, 60
Link 2
: 3
, 0
, 1
, 61
Link 3
: 3
, 0
, 2
, 62
..
To query information for a specific link, the depth, pcie_index and node for the link must be specified:
mlxlink -d /dev/mst/mt41682_pciconf0 --port_type PCIE --depth 3
--pcie_index 0
--node 1
--show_serdes_tx --show_eye PCIe Operational (Enabled) Info
-------------------------------
Depth, pcie index, node : 3
, 0
, 1
Link Speed Active (Enabled) : 8G-Gen 3
(16G-Gen 4
)
Link Width Active (Enabled) : 2X (16X)
EYE Opening Info (PCIe)
-----------------------
Physical Grade : 84
, 84
Height Eye Opening [mV] : 1194
, 1194
Phase Eye Opening [psec] : 84
, 84
Serdes Tuning Transmitter Info (PCIe)
-------------------------------------
Serdes TX parameters : Pol ,tap0 ,tap1 ,tap2 ,bias ,preemp_mode ,reg ,leva
Lane 0
: 0
,21
,92
,7
,15
,1
,10
,9
Lane 1
: 1
,21
,92
,7
,15
,1
,10
,9
Lane 2
: 0
,21
,92
,7
,15
,1
,10
,9
Lane 3
: 1
,21
,92
,7
,15
,1
,10
,9
Lane 4
: 0
,21
,92
,7
,15
,1
,10
,9
Lane 5
: 1
,21
,92
,7
,15
,1
,10
,9
Lane 6
: 0
,21
,92
,7
,15
,1
,10
,9
Lane 7
: 1
,21
,92
,7
,15
,1
,10
,9
To print the output in JSON format:
mlxlink -d <device> --show_module --json
To show ports group map (for NVIDIA Quantum and NVIDIA Spectrum-2):
mlxlink –d<device> --show_tx_group_map 0
To assign ports to a specific group on NVIDIA Quantum and NVIDIA Spectrum-2:
mlxlink –d <device> --tx_group_map 1
–ports 1
,2
,3
,5
,4
,8
,7
,8
,9
,10
,11
To show histogram of FEC errors:
mlxlink -d /dev/mst/mt4125_pciconf0 --rx_fec_histogram --show_histogram
To clear histogram:
mlxlink -d /dev/mst/mt4125_pciconf0 --rx_fec_histogram --clear_histogram
The margin scan tool is used for scanning PCIe or Network ports (in EDR\25G or HDR\PAM4 speeds).
If the margin scan fails with an "eye scan not completed" message, perform a reboot and run the scan again.
To enable the margin scan with a measure time of 10 seconds:
mlxlink –d <device> --port_type PCIE –margin –measure_time 10
To enable the margin scan for Multi-host or Socket Direct systems through:
depth, pcie_index and node:
mlxlink –d <device> --port_type PCIE –depth
0
–pcie_index1
–node0
–margin –measure_time30
The local port (can be shown by the –show_links command):
mlxlink –d <device> --port_type PCIE –port
1
–margin –measure_time10
Allows modifying the Eye Center capability by changing the mixer_offset0 (fine change) and mixer_offset1 (coarse change) flags for 28nm products to produce RX errors.
Flags Usage
To change the mixers values:
mlxlink -d /dev/mst/mt4117_pciconf0 --rx_error_injection --mixer_offset0
0x200
--mixer_offset10x305
WarningModifying mixer_offset0 and mixer_offset1 flags can change the Eye Center and might cause link degradation.
To query the mixers values:
mlxlink -d /dev/mst/mt4117_pciconf0 --rx_erro r_injection --show_mixers_offset
The module PRBS test mode can be performed by using the new flags under the --cable command.
This feature supports Active/Optical CMIS modules only.
Either the media or host side can run with PRBS mode.
To enable the PRBS test mode, the module should be plugged in and active.
Enabling\Disabling The Module PRBS Test Mode
To enable the module PRBS test mode, the side of the module should be selected using the --prbs_select flag. After providing the --cable flag, either the HOST or the MEDIA side should be selected, so the --prbs_mode <EN\DS> can be used to enable or disable the PRBS test mode process.
E.g.: the following command will enable the PRBS test mode on the HOST side of the module:
mlxlink -d /dev/mst/mt53104_pciconf0 --port 3
--cable --prbs_select HOST --prbs_mode EN
The command above will put the HOST side of the module in PRBS test mode with default Checker and Generator parameters.
The Checker and Generator parameters can be overridden while enabling the PRBS test mode according to their related flags in the help menu:
mlxlink -d /dev/mst/mt53104_pciconf0 --port 3
--cable --prbs_select HOST --prbs_mode EN --checker_pattern PRBS13 --invert_checker --generator_pattern PRBS31 --swap_generator --lane_rate HDR
To disable the PRBS test mode, the following command can be executed:
mlxlink -d /dev/mst/mt53104_pciconf0 --port 3
--cable --prbs_select HOST --prbs_mode DS
PRBS Diagnostic Counters Information
After performing the PRBS test mode, the module counters can be queried by using the following command:
mlxlink -d /dev/mst/mt53104_pciconf0 --port 3
--cable --prbs_select HOST --show_diagnostic_info
The module PRBS test mode counters can be cleared by using the following command, which will clear the diagnostic counters on the HOST side only:
mlxlink -d /dev/mst/mt53104_pciconf0 --port 3
--cable --prbs_select HOST --clear_diagnostic_info
Some of the module parameters can be controlled by mlxlink after providing the --control_paramenter flag, which can be executed under the --cable flag.
The possible parameters can be controlled as follows:
Reading and configuring Tx Equalization
Reading and configuring Rx Emphasis (PreCursor & PostCursor)
Reading and configuring Rx Amplitude
To apply the changes, the link should be disabled first.
After configuring a new parameter, the link should be raised again to allow the firmware to load the new configuration.
Cable control parameters are valid for active\optical modules only.
Querying and Configuring The Module Control Parameters
To query the currently configured module control parameters, the --control_parameters flag can be used under the --cable flag as follows:
mlxlink -d /dev/mst/mt53104_pciconf0 --cable --control_parameters
...
Module Control Parameters
-------------------------
TX Equalization : 1dB
RX Emphasis (pre) : 2
.5dB
RX Post Emphasis : No Equalization
RX Amplitude : 600
-1200
mV (P-P)
To configure the module control parameters, the following command can be executed:
mlxlink -d /dev/mst/mt53104_pciconf0 --cable --control_parameters --tx_equalization 2
--rx_amplitude 1
When using the mlxlink tool with an adapter card, notice that the "label_port" -p flag should not be used. To address different ports, please use different MST devices.
For example:
To address port 1 when using ConnectX-4:
mlxlink -d /dev/mst/mt4115_pciconf0
To address port 2, use:
mlxlink -d /dev/mst/mt4115_pciconf0.1
Any mlxlink command for a switch should include the "-p" flag to address the specific port in the switch.
When working with an adapter card, if an MTUSB is used for communication with the NVIDIA NIC, to address port 2, use mlxlink -d /dev/mst/mt4115_pciconf0 --gvmi_address<0xAddress>.
If the split port number is not provided by the ibdiagnet tool, to use mlxlink on NVIDIA Quantum HDR based switch systems split ports, run:
mlxlink -d lid-<LID> -p <formula>
Formula:
In case of 2X port:
1- port_num = round_down[(Iblinkinfo_port_num + 1)*0.5]
2- if (Iblinkinfo_port_num + 1) modulo 2 =1 then append ‘/2’ to port_num
In case of 4X port, use only item #1 above.
Example:
43
23
[ ] ==( 2X 53.125
Gbps Active/ LinkUp)==> mlxlink -d lid-43
-p 12
43
24
[ ] ==( 2X 53.125
Gbps Active/ LinkUp)==> mlxlink -d lid-43
-p 12
/2
In NVIDIA Quantum-2 NDR switch systems, there are 32-OSFP cages (8x), where each one holds 2 (4x) ports instead of 1, and each port can be accessed by providing the cage number and the port in the cage - “Cage/Port”.
mlxlink -d <mst deivce> -p <Cage>/<Port>
If the split profile is ready, it is possible to access the split ports by providing the number of split to the port flag, e.g.:
To access the main port of 15/2:
mlxlink -d <mst deivce> -p
15
/2
To access the split port of 15/2:
mlxlink -d <mst deivce> -p
15
/2
/2
Link Speed and Width
For PCIe link speed and width, use the following flag: --port_type PCIE.
PCIe Operational (Enabled) Info
-------------------------------
Depth, pcie index, node : [Depth, pcie index, node]
Link Speed Active (Enabled) : [Freq – Gen]
Link Width Active (Enabled) : [Width]
PCIe Switch
When using NVIDIA ConnectX-5 and newer devices, the PCIe interface can be configured for a PCIe switch. When the PCIe switch is enabled, the depth, pcie_index and node parameters are needed in order to specify the PCIe port from which the requested information (such as counters or eye info) is gathered.
Parameters |
Description |
Depth |
This parameter defines the number of layers from the Root Complex to the specific port.
|
Pcie_index |
This parameter defines the root complex ID or host index.
|
Node |
This parameter defines the specific PCIe port.
Note: For NVIDIA BlueField/BlueField-2 SmartNIC mode, the PCIe link information can only be gathered from the external host. The PCIe interface status cannot be retrieved from the Arm side. When retrieving the PCIe link information from the external host, there is no need to specify the depth, pcie_index and node. |
Example: NVIDIA BlueField JBoF Mode
# mlxlink -d /dev/mst/mt41682_pciconf0 --port_type pcie --depth 3
--pcie_index 0
--node 4
-c
PCIe Operational (Enabled) Info
-------------------------------
Depth, pcie index, node : 3
, 0
, 4
Link Speed Active (Enabled) : 8G-Gen 3
(16G-Gen 4
)
Link Width Active (Enabled) : 2X (2X)
Management PCIe Timers Counters Info
------------------------------------
dl down : 0
Management PCIe Performance Counters Info
-----------------------------------------
RX Errors : 0
TX Errors : 0
CRC Error dllp : 0
CRC Error tlp : 0
Link Counters
For PCIe counters information, use the --port_type PCIE –c flag.
Management PCIe Timers Counters Info
------------------------------------
dl down : [link down counter]
Management PCIe Performance Counters Info
-----------------------------------------
RX Errors : [Rx Errors]
TX Errors : [Tx Errors]
CRC Error dllp : [CRC Errors dllp]
CRC Error tlp : [CRC Errors tlp]
RX Errors: indicate the number of transitions to recovery required due to framing errors and CRC (dlp and tlp) errors.
TX Errors: indicate the number of transitions to recovery required due to EIEOS and TS errors.
CRC Error dllp: indicate CRC error in Data Link Layer Packets.
CRC Error tlp: indicate CRC error in Transaction Layer Packet.
Example:
# mlxlink -d /dev/mst/mt4123_pciconf0 --port_type PCIE -c
PCIe Operational (Enabled) Info
-------------------------------
Depth, pcie index, node : 0
, 0
, 0
Link Speed Active (Enabled) : 16G-Gen 4
(16G-Gen 4
)
Link Width Active (Enabled) : 16X (16X)
Management PCIe Timers Counters Info
------------------------------------
dl down : 3
Management PCIe Performance Counters Info
-----------------------------------------
RX Errors : 0
TX Errors : 16
CRC Error dllp : 0
CRC Error tlp : 0
Link Eye Opening and Grade
For PCIe link physical grade and eye opening information, use the --port_type PCIE –e flag.
EYE Opening Info (PCIE)
------------------------
Physical Grade : [Grade0, Grade1, Grade2, Grade3, Grade4, Grade5, Grade6, Grade7, Grade8, Grade9, Grade10, Grade11, Grade12, Grade13, Grade14, Grade15]
Height Eye Opening [mV] : [Height0, Height1, Height2, Height3, Height4, Height5, Height6, Height7, Height8, Height9, Height10, Height11, Height12, Height13, Height14, Height15]
Phase Eye Opening [psec] : [Phase0, Phase1, Phase2, Phase3, Phase4, Phase5, Phase6, Phase7, Phase8, Phase9, Phase10, Phase11, Phase12, Phase13, Phase14, Phase15]
Example:
# mlxlink -d /dev/mst/mt4123_pciconf0 --port_type PCIE -e
PCIe Operational (Enabled) Info
-------------------------------
Depth, pcie index, node : 0
, 0
, 0
Link Speed Active (Enabled) : 16G-Gen 4
(16G-Gen 4
)
Link Width Active (Enabled) : 16X (16X)
EYE Opening Info (PCIe)
-----------------------
Physical Grade : 57279
, 56340
, 59340
, 61824
, 55140
, 60501
, 61530
, 57392
, 61573
, 58930
, 62752
, 60421
, 57188
, 59796
, 60066
, 60847
Height Eye Opening [mV] : 292
, 288
, 314
, 325
, 278
, 310
, 319
, 299
, 316
, 318
, 343
, 323
, 310
, 311
, 335
, 318
Phase Eye Opening [psec] : 30
, 30
, 30
, 30
, 30
, 30
, 30
, 30
, 30
, 28
, 28
, 28
, 28
, 30
, 28
, 30
Pass/Fail Criteria
SLRED (ConnectX-6/ConnectX-6 Dx/ConnectX-6 Lx)
mlxlink -d [device] --port_type PCIE --margin
Gen3
Gen3 |
|
Eye Grade |
Figure of Merit (FOM) |
0 < Eye Grade < 700 |
FAIL |
700 < Eye Grade < 2300 |
Gray area |
2300 < Eye Grade |
PASS |
Gen4
Gen4 |
|
Eye Margin |
FOM |
0 < Eye Grade < 150 |
FAIL |
150 < Eye Grade < 400 |
Gray area |
400 < Eye Grade |
PASS |
PCIE Error Injection
This test feature allows errors injection over the PCI links. It is used to verify that the system can handle the PCIe errors, which rarely occur in regular usage.
The ConnectX-7 device includes testability features that can be configured to act as an error injection ‘exerciser’ in order to test other components in the system. This is supported when the ConnectX-7 is used as a PCIe switch.
This is a PCIe related feature that should be run over PCIe links only (--port_type PCIE) with specific depth, PCIe index and node (DPN).
If the DPN is not provided, the tool will take the default values - 0,0 and 0, respectively.
The mapping between the BDF and its DPN can be found by executing the show_links command (see example below).
Error Types
ID |
Error Type |
Description |
Unit |
Additional Parameters (--errors_parameters) |
Advanced Error Reporting Flag Set by This Error |
0 |
ABORT |
Cancels the current pending error, if exists. |
NA |
NA |
NA |
1 |
BAD_DLLP_LCRC |
Flips a bit in the LCRC of the next “error_duration” DLLPs that are transmitted through the port. |
Packets |
NA |
Bad DLLP Status |
2 |
BAD_TLP_LCRC |
Flips a bit in the LCRC of the next “error_duration” TLPs that are transmitted through the port. The packets are VDM TLPs that are sent by the port to the destination BDF - “dbdf”. |
Packets |
NA |
Bad TLP Status |
3 |
BAD_TLP_ECRC |
Flips a bit in the ECRC of the next “error_duration” TLPs that are transmitted through the port. The packets are VDM TLPs that are sent by the port to the destination BDF - “dbdf”. |
Packets |
NA |
ECRC Error Status |
4 |
ERR_MSG |
Sends an error signaling message to the RC. |
Packets |
Parameter 0: message type 0 - Correctable 1 - Nonfatal 2 - Fatal |
ERR_COR Received / Non-Fatal Error Messages Received / Fatal Error Messages Received |
5 |
MALFORMED_ TLP |
Sends an “error_duration” PM_ACTIVE_STATE_NACK message to the destination BDF - “dbdf” with TC=1 instead of 0. |
Packets |
NA |
Malformed TLP Status |
6 |
POISONED_TLP |
Sends an “error_duration” VDMs with data to the destination BDF - “dbdf” with EP = 1. |
Packets |
NA |
Poisoned TLP Received |
7 |
UNEXPECTED_CPL |
Sends “error_duration” completions to the destination BDF - “dbdf” with 0xff tag. |
Packets |
NA |
Unexpected Completion Status |
8 |
ACS_VIOLATION |
Sends “error_duration” VDMs to the destination BDF - “dbdf” with source_bdf=0. |
Packets |
NA |
ACS Violation Status |
100 |
SURPRISE_LINK_DOWN |
Sets a port state to DETECT. |
NA |
NA |
Surprise Down Error Status |
101 |
RECEIVER_ERROR |
Sends a clock instead of data for “error_duration” usecs. A value of 0 in ‘error_duration’ means that this error must be toggled by the firmware as fast as possible. |
uSec |
NA |
Receiver Error Status |
PCIe Error Injection Inputs
The following values should be provided in the error injection command line. Some values may be optional according to the error type.
Input |
Command Line Flag |
Description |
Obligatory |
Default |
Error Type |
--error_type |
Error type according to the table above. |
Yes |
- |
Error Duration |
--duration |
The minimal number of packets with this error that will be sent, or the minimal amount of time that this error state would be applied. |
No |
1 |
Injection Delay |
--injection_delay |
Delay in microseconds before the error is applied. This allows time for the completion to return to the tool caller correctly. A higher value can be used to allow the system to get to a lower power state. |
No |
0 |
Destination BDF |
--dbdf |
Destination BDF. Relevant for some of the errors that require packet generation. See error table above. |
No |
0:00.0 |
Additional Parameters |
--errors_parameters |
Additional parameters according to the error type. See error table above. |
No |
0 |
Mlxlink will trigger the firmware to start the error injection process by providing the --pcie_error_injection flag with the requested configuration parameters.
Note that the command returns immediately, but the error injection can take longer to complete (according to the error duration and injection delay inputs).
When the tool is run without the parameters above, it will query the error injection state – Whether it is ready to start a new error injection, or it is in the middle of the previous injection.
Usage Example
Start the process by performing error injection with error type UNEXPECTED_CPL.
This example shows how to start the error injection by sending 5 unexpected completion packets. The packets (of error type UNEXPECTED_CPL (id 7)) are directed from BDF 05:00.0 to BDF 06:0.0 after 500µs of sending the command in the following environment:
PCIe Component |
BDF |
Root port |
00:01.0 |
(exerciser) PCIe Switch Upstream port |
01:00.0 |
(exerciser) PCIe Switch Downstream port |
05:00.0 |
Endpoint |
06:00.0 |
To get the related depth, pcie_index and node for the specific BDF 05:00.0, the show_links command should be executed as follows:
Show Links
mlxlink -d /dev/mst/mt4129_pciconf0 --port_type PCIE --show_links
Valid PCIe Links
----------------
Legend : depth ,pcie_index ,node ,port ,bdf
Link 1 : 0 ,0 ,0 ,0 ,01:00.0
Link 2 : 3 ,0 ,0 ,60 ,05:00.0
In this case, the depth, pcie_index, and node flags for the downstream port should be 3, 0, and 0, respectively.
Then, the following command can be executed to start the process:
Start PCIe Error Injection
mlxlink -d /dev/mst/mt4129_pciconf0 --port_type PCIE --depth 3 --pcie_index 0 --node 0 --pcie_error_injection --error_type UNEXPECTED_CPL --error_duration 5 --dbdf 06:00.0 --injection_delay 500
PCIe Operational (Enabled) Info
-------------------------------
Depth, pcie index, node : 3, 0, 0
Link Speed Active (Enabled) : 16G-Gen 4 (16G-Gen 4)
Link Width Active (Enabled) : 16X (16X)
PCIe error injection might cause a PCIe bus failures or a system hang
Do you want to continue
? yes
Starting PCIe Error Injection...
Query Error Injection Status
After sending the configuration command, the progress of the process can be checked by executing the tool with the pcie_error_injection flag only:
Query PCIe Error Injection Status 1
mlxlink -d /dev/mst/mt4129_pciconf0 –-port_type PCIE --depth 3 --pcie_index 0 --node 0 –-pcie_error_injection
PCIe Operational (Enabled) Info
-------------------------------
Depth, pcie index, node : 3, 0, 0
Link Speed Active (Enabled) : 16G-Gen 4 (16G-Gen 4)
Link Width Active (Enabled) : 16X (16X)
PCIe Error Injection Info
-------------------------
Error Injection Status : In progress
Error Injection Type : UNEXPECTED_CPL
Error Injection Duration : 5 Packets
Once the process is complete, the output will be changed to "ready". This means that another error injection request can be submitted:
Query PCIe Error Injection Status 2
mlxlink -d /dev/mst/mt4129_pciconf0 –-port_type PCIE --depth 3 --pcie_index 0 --node 0 –-pcie_error_injection
PCIe Operational (Enabled) Info
-------------------------------
Depth, pcie index, node : 3, 0, 0
Link Speed Active (Enabled) : 16G-Gen 4 (16G-Gen 4)
Link Width Active (Enabled) : 16X (16X)
PCIe Error Injection Info
-------------------------
Error Injection Status : Ready
Error Injection Type : N/A
Error Injection Duration : N/A