13.1.6. References

Copy
Copied!
            

{ "DicomAdapter": { "readAeTitlesFromCrd": false, // indicates whether to read Clara AE Titles, DICOM Sources and DICOM Destinations from Kubernetes CRD. (default: true), "crdReadIntervals": 10000, // indicates how often to update AE Titles from Kubernetes CRD in milliseconds. "dicom": { "scp": { "port": 104, // DICOM SCP listening port. (default 104) "aeTitles": [ // A list of AE Titles used to accept and associate DICOM instances when `readAeTitlesFromCrd` is set to `false`, { "name": "brain-tumor", // name of ae title "aeTitle": "Brain-Tumor-AE", // DICOM AE Title "overwriteSameInstance": false, // whether or not to overwrite existing instance with same SOP Instance UID "ignoredSopClasses": [], // an array of strings containing SOP Class UIDs that is used to blacklist (ignore and not store) received instances. "processor": "Nvidia.Clara.DicomAdapter.Server.Processors.AeTitleJobProcessor, Nvidia.Clara.DicomAdapter", // job process to attach to this AE Title (default: Nvidia.Clara.DicomAdapter.Server.Processors.AeTitleJobProcessor, Nvidia.Clara.DicomAdapter) "processorSettings": { // settings to be used by the configured Job Processor. Please refer to Job Processors page for additional information. "timeout": 5, "pipeline-brain-tumor": "12345" } }, ], "maximumNumberOfAssociations": 100, // maximum number of concurrent associations. (range: 1-1000, default: 100) "verification": { "enabled": true, // respond to c-ECHO commands (default: true) "transferSyntaxes": [ "1.2.840.10008.1.2.1", // Explicit VR Little Endian "1.2.840.10008.1.2" , // Implicit VR Little Endian "1.2.840.10008.1.2.2", // Explicit VR Big Endian ] } "log-dimse-datasets": false, // whether or not to write command and dataset to log (default false) "reject-unknown-sources": true, // whether to reject unknown sources not listed in the source section. (default true) "sources": [] // a list know know DICOM sources }, "scu": { "ae-title": "ClaraSCU", // AE Title of the SCU service "log-dimse-datasets": false, // whether or not to write command and data datasets to the log. "log-data-pdus": false, // whether or not to write message to log for each P-Data-TF PDU sent or received "maximumNumberOfAssociations": 2, // maximum number of outbound DICOM associations (range: 1-1000, default: 2) } }, "storage" : { "temporary" : "/payloads" // storage path used for storing received instances before uploading to Clara Platform. } }, "Serilog": { "Using": [ "Serilog.Sinks.Console" ], "MinimumLevel": "Information", // log filter level. (Available optioins: Debug, Information, Warning, Error) "WriteTo": [ { "Name": "Console", "Args": { "theme": "Serilog.Sinks.SystemConsole.Themes.AnsiConsoleTheme::Code, Serilog.Sinks.Console", "outputTemplate": "{Timestamp:yyyy-MM-dd HH:mm:ss.fff zzz} [{Level:u4}] [{MachineName}] {SourceContext}[{ThreadId}] {Properties} {Message:l}{NewLine}{Exception}" } }, { "Name": "File", "Args": { "path": "logs/clara-dicom.log", "rollingInterval": "Day", "rollOnFileSizeLimit": true, "outputTemplate": "{Timestamp:yyyy-MM-dd HH:mm:ss.fff zzz} [{Level:u4}] [{MachineName}] {SourceContext}[{ThreadId}] {Properties} {Message}{NewLine}{Exception}" } } ], "Enrich": [ "FromLogContext", "WithMachineName", "WithThreadId" ] }, "Logging": { "LogLevel": { "Default": "Information", "Microsoft": "Warning", "Microsoft.Hosting.Lifetime": "Information", "Microsoft.AspNetCore.Mvc.Infrastructure.ControllerActionInvoker": "Error" } }, "AllowedHosts": "*" }

13.1.6.1.1. Configuration Validation

Clara DICOM Adapter validates all settings during start i[]. Any provided values that are invalid or missing may cause the service to crash. If you are the running DICOM Adapter inside Kubernetes/Helm, you may see the CrashLoopBack error. To review the validation errors, simply run kubectl logs <name-of-dicom-adapter-pod>.

© Copyright 2018-2020, NVIDIA Corporation. All rights reserved. Last updated on Feb 1, 2023.