This page documents the data that the NVIDIA Fleet Intelligence Out-of-Band Collector collects from the baseboard management controller (BMC) of each enrolled compute node. It also explains why each item is collected. Out-of-band (OOB) collection reads hardware data from the BMC through the Redfish management API. It works independently of the host operating system, so it complements the data that the in-band agent collects. Refer to Data Collection Rationale - In Band for the in-band data, and to the Out-of-Band Collector documentation for the collector itself. Metric descriptions follow the definitions in the DMTF Redfish schemas.
The data is organized into four sections. Labels describe each series and identify the node, the BMC, and the part that a metric describes. Telemetry Metrics are recurring time-series data that the BMC reports for sensors, processors, memory, storage, and power supplies. Alerts are the messages that the collector generates when a sensor reading crosses a threshold that the BMC defines. Logs are the event records, health reports, and firmware inventory that the collector reads from the BMC.
The collector names every metric with the fleetint_hw_ prefix.
Sensor metrics are the primary collection path, and they are collected by default.
The BMC defines the caution and critical thresholds for each sensor.
The collector also collects drive media life and power supply capacity metrics by default because it derives them from sensor and inventory data.
To collect all other processor, memory, storage, and power supply metrics, enable the metrics collector.
Those metrics come from the Redfish metrics resources, which have no sensor equivalent.
The collector skips any value that a sensor already reports to avoid reporting it twice.
Labels
The collector attaches the following labels to every series.
| Label | Description | Rationale |
|---|---|---|
| collector_type | Type of collector that produced the series. | Separates data by collection path so that queries can target one path. |
| endpoint_key | Key that identifies the BMC endpoint that the data came from. | Distinguishes data from different endpoints when a node has more than one. |
| endpoint_ip | IP address of the BMC endpoint. | Identifies the management interface that produced the data to help you troubleshoot connectivity and correlation. |
| endpoint_mac | MAC address of the BMC endpoint. | Provides a stable hardware identifier for the BMC when IP addresses change. |
| machine_id | Machine identifier, which is the same value that the in-band agent reports. | Joins out-of-band data with in-band data for the same node. |
The collector also attaches the following labels, depending on the type of part that a metric describes.
| Label | Description | Rationale |
|---|---|---|
| sensor_name | Name of the sensor that produced the reading. | Identifies which sensor a reading came from. |
| physical_context | The area or device that the sensor measures, such as a GPU, a CPU, memory, a power supply, or the air intake. | Groups readings by the part or area that they describe. |
| processor_id, system_id, processor_type, model | Identity of the processor, with the type and model when the BMC reports them. | Attributes processor metrics to one processor in one system. |
| memory_id, system_id, device_type, model | Identity of the memory device, with the type and model when the BMC reports them. | Attributes memory metrics to one memory device in one system. |
| drive_id, storage_id, system_id, model | Identity of the drive, with the model when the BMC reports it. | Attributes storage metrics to one drive in one system. |
| powersupply_id, chassis_id, model | Identity of the power supply, with the model when the BMC reports it. | Attributes power supply metrics to one supply in one chassis. |
| sensor_range | Whether a range metric reports the maximum or the minimum of a sensor. | Distinguishes the upper limit from the lower limit on range metrics. |
Telemetry Metrics
Thermal and Cooling Sensors
The following table lists the BMC temperature and cooling sensor metrics.
| Metric | Description | Rationale |
|---|---|---|
| fleetint_ | Temperature, in degrees Celsius, that a BMC sensor reports. The physical_context label identifies the area or device that the sensor measures, such as a GPU, a CPU, memory, or intake air. | Gives a temperature view that does not depend on the host operating system, so it still works when the host is unresponsive or offline. The BMC sets caution and critical thresholds for each sensor, and alerts use them. Use it with the in-band GPU and CPU temperatures to confirm overheating. |
| fleetint_ | Rotational speed of a fan or pump, in revolutions per minute (RPM). | A slow or stopped fan or pump is a common cause of rising temperatures. Comparing speed with temperature separates a cooling failure from heat that the workload generates. |
| fleetint_ | Flow rate of liquid through a cooling loop, in liters per second. | Low flow in a liquid cooling loop can cause rapid overheating. Tracking flow helps detect pump failures and blockages before components throttle. |
| fleetint_ | Liquid level in a cooling loop, in centimeters. | A falling level indicates coolant loss. Tracking it gives early warning before flow and temperatures are affected. |
| fleetint_ | Air flow, in cubic feet per minute. | Confirms that fans move enough air through the chassis. Low air flow explains temperature increases when fan speeds look normal. |
Power Sensors
The following table lists the BMC power sensor metrics.
| Metric | Description | Rationale |
|---|---|---|
| fleetint_ | Power, in watts, that a BMC sensor reports for a component or area. | Provides an independent power reading for each component. Use it for capacity planning, for detecting abnormal draw, and for cross-checking the power that the in-band agent reports. |
| fleetint_ | Voltage, in volts, that a BMC sensor reports. The reading can be alternating current (AC) or direct current (DC). | Voltage outside the expected range signals unstable or failing power delivery, which can cause errors, throttling, or shutdowns. |
| fleetint_ | Electrical current, in amperes, that a BMC sensor reports. | Explains power draw together with voltage and helps locate overloaded or failing power paths. |
| fleetint_ | Frequency, in hertz, that a BMC power sensor reports. | Frequency outside the normal range indicates a problem with the electrical supply. |
| fleetint_ | Cumulative energy, in joules. | Cumulative energy counters support energy accounting and cost calculations, and they show which nodes use the most power over time. |
| fleetint_ | Cumulative energy, in watt-hours. | Captures energy readings from BMCs that report in watt-hours instead of joules. It measures the same quantity as the joules metric. |
| fleetint_ | Cumulative energy, in kilowatt-hours. | Captures energy readings from BMCs that report in kilowatt-hours instead of joules. It measures the same quantity as the joules metric. |
| fleetint_ | Electrical charge, in ampere-hours (Ah). | Tracks stored charge for components that report it, so that you can detect low charge before it affects the node. |
Environmental Sensors
The following table lists the BMC environmental sensor metrics.
| Metric | Description | Rationale |
|---|---|---|
| fleetint_ | Relative humidity, as a percent. | High humidity risks condensation and corrosion, and low humidity risks static discharge. Tracking it verifies that the environment stays within the operating range. |
| fleetint_ | Absolute humidity, in grams of water per cubic meter. | Complements relative humidity because condensation risk depends on both humidity and temperature. |
| fleetint_ | Pressure, in pascals. | Reports pressure readings from environmental sensors. Changes can indicate air flow or cooling problems. |
| fleetint_ | Pressure, in kilopascals. | Captures pressure readings from BMCs that report in kilopascals instead of pascals. |
| fleetint_ | Barometric (ambient air) pressure, in millimeters of mercury. | Provides ambient pressure context for cooling performance, which varies with altitude and weather. |
| fleetint_ | Altitude. The Redfish standard defines this reading in meters, but the NVIDIA GH200 BMC reports it in pascals. | Records the installation altitude, which affects air-cooling capacity. Treat it as inventory data. |
| fleetint_ | Generic percentage reading. The meaning depends on the sensor. | Captures percentage sensors that do not fit another reading type. Use the sensor_name label to interpret the value. |
Sensor Ranges
The following table lists the metrics that report the valid range of a sensor.
| Metric | Description | Rationale |
|---|---|---|
fleetint_hw_sensor_<reading_type>_range_max_<unit> | Maximum possible value that a sensor can report, for any sensor reading type above. | Defines the upper end of the valid range for a sensor. A reading outside the range points to a faulty sensor instead of a hardware problem, so the range helps separate the two. |
fleetint_hw_sensor_<reading_type>_range_min_<unit> | Minimum possible value that a sensor can report, for any sensor reading type above. | Defines the lower end of the valid range for a sensor. It serves the same purpose as the maximum for readings that fall too low. |
Processor Metrics
The following table lists the metrics that the BMC reports for each processor on its Redfish processor metrics resource.
| Metric | Description | Rationale |
|---|---|---|
| fleetint_ | Average frequency across all enabled cores of the processor, in MHz. | Shows whether the processor runs at the expected frequency over time. Sustained low frequency points to throttling or power-management problems. |
| fleetint_ | Processor frequency relative to the nominal processor frequency ratio. | Normalizes frequency across processor models so you can compare nodes and find processors that run below nominal frequency. |
| fleetint_ | The processor margin to throttle, as a temperature offset in degrees Celsius. | Shows how close the processor is to thermal throttling. Use it with the throttle duration metrics to understand why a processor slows down. |
| fleetint_ | Total time that a thermal limit throttled the processor since reset, in seconds. | Separates temperature-driven throttling from other causes of reduced performance. High values indicate a need for better cooling or air flow. |
| fleetint_ | Total time that a power limit throttled the processor since reset, in seconds. | Identifies processors held back by power caps or power-supply constraints. High values suggest that the power budget is too low for the workload. |
| fleetint_ | Power that the processor has consumed, in watts. | Provides per-processor power for capacity planning and for detecting abnormal draw. |
| fleetint_ | Core voltage of the processor, in volts. | Unstable or low core voltage can cause errors and throttling, so tracking it helps find power-delivery problems at the processor. |
| fleetint_ | Local memory bandwidth usage of the processor, in bytes. | Shows how much memory traffic stays on memory attached to the same processor. Local access is faster than remote access. |
| fleetint_ | Remote memory bandwidth usage of the processor, in bytes. | Shows how much memory traffic crosses to memory attached to another processor. A high remote share slows workloads and indicates poor memory placement. |
| fleetint_ | Share of time that the processor has spent in kernel mode, as a percent. | Separates operating system work from application work. A high kernel share can indicate driver or input and output overhead. |
| fleetint_ | Share of time that the processor has spent in user mode, as a percent. | Shows how much processor time applications use. Together with kernel time, it explains where processor time goes. |
| fleetint_ | Number of correctable errors in the processor cores, such as translation lookaside buffer (TLB) or cache errors. | The hardware fixed these errors, but a rising count is an early warning of a degrading processor. |
| fleetint_ | Number of uncorrectable errors in the processor cores, such as TLB or cache errors. | The hardware could not fix these errors. Any increase needs investigation and can mean the processor must leave service. |
| fleetint_ | Number of correctable errors in all other processor components. | Covers processor components other than the cores. A rising count is an early warning of a degrading part. |
| fleetint_ | Number of uncorrectable errors in all other processor components. | Covers processor components other than the cores. Any increase needs investigation. |
| fleetint_ | Total number of Peripheral Component Interconnect Express (PCIe) replays that the device issued. A replay is a resend of a packet after the acknowledgment timer expires. | Replays indicate transmission problems on the PCIe link. Sustained growth suggests signal-integrity problems in cabling, risers, or the board. |
| fleetint_ | Total number of PCIe replay rollovers that the device issued. A rollover happens when repeated replays fail and force the link into recovery. | Shows that the link could not repair itself through replays alone. Any increase indicates a seriously degraded link. |
| fleetint_ | Total number of correctable PCIe errors for the device. | The link recovered from these errors without data loss, but growth indicates a degrading link. |
| fleetint_ | Total number of non-fatal PCIe errors for the device. | These errors disrupt a transfer but leave the link usable. Growth indicates a link that needs attention. |
| fleetint_ | Total number of fatal PCIe errors for the device. | These errors break the link. Any increase needs immediate investigation. |
| fleetint_ | Total number of times the PCIe link moved from the normal operating state (L0) to the recovery state. | Frequent recovery events show that the link repairs itself often, which indicates poor signal quality. |
| fleetint_ | Total number of bad transaction layer packets (TLPs) on the PCIe link. A bad TLP is one that the transaction layer cannot process, for example because of corruption or a checksum mismatch. | Bad packets force retransmission and slow transfers. Growth points to link quality problems. |
| fleetint_ | Total number of bad data link layer packets (DLLPs) on the PCIe link. A bad DLLP is damaged or malformed. | Damaged link-management packets indicate signal problems at a lower layer than packet data errors. |
| fleetint_ | Total number of negative acknowledgments (NAKs) that the device sent on the PCIe link, for example after it missed or could not decode a packet. | Shows how often this side received bad data and asked for it again. |
| fleetint_ | Total number of NAKs that the receiver on the other end of the PCIe link sent. | Shows how often the other side rejected data that this side sent. |
| fleetint_ | Total number of PCIe flow control credit timeouts. | Timeouts indicate a link-level problem and typically cause link recovery. |
| fleetint_ | Total number of unsupported PCIe requests that the device received. | Indicates misdirected or unsupported requests, which can point to configuration or firmware problems. |
Shared Processor, Memory, and Power Supply Metrics
The BMC reports the following metrics for more than one type of part.
| Metric | Description | Rationale |
|---|---|---|
| fleetint_ | Temperature, in degrees Celsius, of a processor or a power supply. | Provides per-part temperature in addition to the generic sensor readings. Overheating processors and power supplies throttle or shut down. |
| fleetint_ | For a processor, the processor utilization as a percent. For a memory device, the memory bandwidth utilization as a percent. | Shows how busy processors are and how close memory runs to its data-movement capacity. Sustained high memory values indicate bandwidth-bound workloads. |
| fleetint_ | Operating speed of a processor, in MHz, or of a memory device, in MHz or mega-transfers per second (MT/s). | Confirms that components run at the expected speed. Lower speeds indicate throttling, power-saving states, or configuration problems. |
Memory Metrics
The following table lists the metrics that the BMC reports for each memory device.
| Metric | Description | Rationale |
|---|---|---|
| fleetint_ | Number of correctable error-correcting code (ECC) errors since the last reset. | Shows short-term corrected error activity. Spikes help detect environmental or workload-triggered memory problems without being dominated by old history. |
| fleetint_ | Number of uncorrectable ECC errors since the last reset. | Counts recent errors that ECC could detect but not fix. They indicate data corruption and potential system instability. |
| fleetint_ | Number of correctable ECC errors for the lifetime of the memory. | Shows the long-term health of the memory. Use it to rank devices by error history and decide which to replace first. |
| fleetint_ | Number of uncorrectable ECC errors for the lifetime of the memory. | Tracks how many serious memory failures a device has had. High counts suggest a history of instability. |
| fleetint_ | Number of corrected errors in volatile memory. | Shows how often regular memory needs correction. A rising count is an early warning of a degrading device. |
| fleetint_ | Number of corrected errors in persistent memory. | Applies only to systems with persistent memory modules. A rising count is an early warning of a degrading module. |
| fleetint_ | Number of indeterminate correctable errors since the last reset. The origin of these errors is unknown, so the same error can appear on more than one memory device. | Surfaces errors that the classified counters miss. Treat increases as a warning to investigate. |
| fleetint_ | Number of indeterminate uncorrectable errors since the last reset. The origin of these errors is unknown, so the same error can appear on more than one memory device. | Surfaces errors that the classified counters miss. These errors are more serious than the correctable variant. |
| fleetint_ | Number of indeterminate correctable errors for the lifetime of the memory. | Provides the long-term history for unclassified errors so that you can compare devices. |
| fleetint_ | Number of indeterminate uncorrectable errors for the lifetime of the memory. | Provides the long-term history for serious unclassified errors. |
| fleetint_ | Number of shutdowns that happened while outstanding writes to persistent memory had not completed. | Applies only to persistent memory. Unclean shutdowns can leave data inconsistent and point to power problems. |
| fleetint_ | Share of the memory capacity in use, as a percent. | Shows memory pressure on the node. Use it to find nodes that run out of memory or sit mostly idle. |
| fleetint_ | Block size of the memory structure elements, in bytes. | Describes how the device is organized. It helps verify consistent configuration across nodes. |
Storage Metrics
The following table lists the metrics that the BMC reports for each drive.
| Metric | Description | Rationale |
|---|---|---|
| fleetint_ | Number of correctable read errors for the lifetime of the drive. | A rising count of corrected read errors is an early warning of a wearing or failing drive. |
| fleetint_ | Number of correctable write errors for the lifetime of the drive. | A rising count of corrected write errors is an early warning of a wearing or failing drive. |
| fleetint_ | Number of uncorrectable read errors for the lifetime of the drive. | These errors can mean data loss. Any increase needs investigation. |
| fleetint_ | Number of uncorrectable write errors for the lifetime of the drive. | These errors can mean data loss. Any increase needs investigation. |
| fleetint_ | Total number of bad blocks that the drive reports. | A rising count signals a wearing drive and helps plan replacement. |
| fleetint_ | Predicted percentage of life remaining in the drive media. The collector derives it from drive inventory data. | Predicts when a drive reaches the end of its life so you can replace it before it fails. |
| fleetint_ | Number of hours that the drive has been powered on for its lifetime. | Shows the age of the drive. Use it with error counts to judge drive health. |
| fleetint_ | Current depth of the Native Command Queue, as the Serial Advanced Technology Attachment (SATA) specification defines it. | Shows how heavily the workload loads the drive. A persistently deep queue points to a storage bottleneck. It applies to SATA drives. |
| fleetint_ | Total data read from the drive since the last reset or counter wrap, in kibibytes. | Shows the read workload on the drive for capacity planning and for explaining drive wear. |
| fleetint_ | Total data written to the drive since the last reset or counter wrap, in kibibytes. | Shows the write workload on the drive. Writes drive flash wear, so this helps explain remaining media life. |
Power Supply Metrics
The following table lists the metrics that the BMC reports for each node power supply.
| Metric | Description | Rationale |
|---|---|---|
| fleetint_ | Input voltage of the power supply, in volts. | Input voltage outside the expected range indicates a power-source problem or a failing supply. |
| fleetint_ | Input current of the power supply, in amperes. | Shows how heavily the supply loads the power source and helps find overloaded power paths. |
| fleetint_ | Input power of the power supply, in watts. | Shows the real power cost of the node, including conversion losses. Use it for capacity planning and energy accounting. |
| fleetint_ | Total output power of the power supply, in watts. | Shows the total load on the supply. Comparing it with input power gives the supply efficiency, and comparing it with capacity shows headroom. |
| fleetint_ | Total energy consumption of the power supply, in kilowatt-hours. | Supports energy accounting and cost calculations at the power supply level. |
| fleetint_ | Frequency of the power supply, in hertz. | Frequency outside the normal range indicates a problem with the power source. |
| fleetint_ | Fan speed of the power supply, as a percent. | A slow or stopped power supply fan leads to overheating and failure of the supply. |
| fleetint_ | Maximum power, in watts, that the supply is rated to deliver. The collector derives it from inventory data. | Provides the limit against which to measure load. Compare output power with capacity to determine headroom. |
Alerts
The collector generates an alert when a sensor reading crosses a threshold that the BMC defines. The BMC uses its firmware policy to determine whether a reading indicates a warning or a critical condition. The collector does not apply its own thresholds. Alerts report the raw values that the BMC reports, without conversion. The energy and altitude messages are the exception. They are informational readings that carry no threshold and no severity, so they do not signal a condition that needs action. Each alert uses one of the sensor metrics in Telemetry Metrics.
Alert messages use the following tokens.
| Token | Description |
|---|---|
{criticality} | Severity of the alert, such as warning or critical. |
{sensor_context} | The sensor and the part or area that it measures. |
{value} | The reading that the sensor reported, in the unit of the metric. |
{threshold_condition} | How the reading compares to the threshold, such as above or below. |
{threshold_name} | The threshold that the reading crossed, such as an upper caution or a lower critical threshold. |
{threshold} | The value of that threshold, in the same unit as the reading. |
Thermal Alerts
The following table lists the thermal alerts.
| Alert | Metric | Message | Rationale |
|---|---|---|---|
| Temperature | fleetint_ | {criticality}: BMC temperature — {sensor_context} measured {value} °C, {threshold_condition} the {threshold_name} threshold of {threshold} °C. | Warns of overheating from the BMC point of view. This view still works when the host operating system is unresponsive or offline. A warning gives you time to act before components throttle or shut down. |
Power Alerts
The following table lists the power alerts.
| Alert | Metric | Message | Rationale |
|---|---|---|---|
| Current | fleetint_ | {criticality}: BMC current — {sensor_context} measured {value} A, {threshold_condition} the {threshold_name} threshold of {threshold} A. | Flags a current that is too high or too low in a power path. It can indicate a failing supply or an overloaded circuit. |
| Energy, joules | fleetint_ | BMC energy reading — {sensor_context} measured {value} J. | This informational reading is not a threshold alert. A cumulative counter has no normal range to cross, so the message reports the value only. The value supports energy accounting rather than fault detection. |
| Power draw | fleetint_ | {criticality}: BMC power draw — {sensor_context} measured {value} W, {threshold_condition} the {threshold_name} threshold of {threshold} W. | Flags a component or supply that draws more or less power than the BMC expects. It can point to a fault or an abnormal load. |
| Voltage | fleetint_ | {criticality}: BMC voltage — {sensor_context} measured {value} V, {threshold_condition} the {threshold_name} threshold of {threshold} V. | Flags a voltage outside the safe range. The alert gives early warning of unstable or failing power delivery before errors, throttling, or shutdowns occur. |
| Charge | fleetint_ | {criticality}: BMC charge — {sensor_context} measured {value} A·h, {threshold_condition} the {threshold_name} threshold of {threshold} A·h. | Flags low stored charge on components that report it, so that you can act before the charge affects the node. |
| Energy, kilowatt-hours | fleetint_ | BMC energy reading — {sensor_context} measured {value} kW·h. | This informational reading is not a threshold alert. It reports the same cumulative energy as the joules message for BMCs that report in kilowatt-hours. |
| Energy, watt-hours | fleetint_ | BMC energy reading — {sensor_context} measured {value} W·h. | This informational reading is not a threshold alert. It reports the same cumulative energy as the joules message for BMCs that report in watt-hours. |
| Frequency | fleetint_ | {criticality}: BMC power frequency — {sensor_context} measured {value} Hz, {threshold_condition} the {threshold_name} threshold of {threshold} Hz. | Flags a frequency outside the normal range, which indicates a problem with the electrical supply. |
Cooling Alerts
The following table lists the cooling alerts.
| Alert | Metric | Message | Rationale |
|---|---|---|---|
| Liquid flow | fleetint_ | {criticality}: BMC liquid flow — {sensor_context} measured {value} L/s, {threshold_condition} the {threshold_name} threshold of {threshold} L/s. | Flags low or lost coolant flow, which can cause rapid overheating in a liquid-cooled node. It gives early warning of a pump failure or a blockage. |
| Fan or pump speed | fleetint_ | {criticality}: BMC fan or pump speed — {sensor_context} measured {value} RPM, {threshold_condition} the {threshold_name} threshold of {threshold} RPM. | Flags a fan or pump that runs too slowly or has stopped. A failing fan or pump is a common cause of rising temperatures. |
| Liquid level | fleetint_ | {criticality}: BMC liquid level — {sensor_context} measured {value} cm, {threshold_condition} the {threshold_name} threshold of {threshold} cm. | Flags a low coolant level. It gives early warning of coolant loss before flow and temperatures are affected. |
| Air flow | fleetint_ | {criticality}: BMC air flow — {sensor_context} measured {value} ft³/min, {threshold_condition} the {threshold_name} threshold of {threshold} ft³/min. | Flags low air flow through the chassis. It explains temperature increases when fan speeds look normal. |
Environmental Alerts
The following table lists the environmental alerts.
| Alert | Metric | Message | Rationale |
|---|---|---|---|
| Absolute humidity | fleetint_ | {criticality}: BMC absolute humidity — {sensor_context} measured {value} g/m³, {threshold_condition} the {threshold_name} threshold of {threshold} g/m³. | Flags humidity outside the safe range. Condensation risk depends on both humidity and temperature, so use the alert with the temperature alerts. |
| Barometric pressure | fleetint_ | {criticality}: BMC barometric pressure — {sensor_context} measured {value} mmHg, {threshold_condition} the {threshold_name} threshold of {threshold} mmHg. | Flags unexpected ambient pressure. Pressure changes the cooling capacity of air, so it can explain a cooling shortfall. |
| Generic percentage | fleetint_ | {criticality}: BMC environmental percentage — {sensor_context} measured {value}%, {threshold_condition} the {threshold_name} threshold of {threshold}%. | Flags a percentage sensor that crosses a threshold. The meaning depends on the sensor, so use the sensor context in the message to interpret it. |
| Pressure | fleetint_ | {criticality}: BMC pressure — {sensor_context} measured {value} Pa, {threshold_condition} the {threshold_name} threshold of {threshold} Pa. | Flags pressure changes that can indicate air flow or cooling problems. |
| Pressure, kilopascals | fleetint_ | {criticality}: BMC pressure — {sensor_context} measured {value} kPa, {threshold_condition} the {threshold_name} threshold of {threshold} kPa. | Flags the same pressure changes for BMCs that report in kilopascals. |
| Relative humidity | fleetint_ | {criticality}: BMC relative humidity — {sensor_context} measured {value}%, {threshold_condition} the {threshold_name} threshold of {threshold}%. | Flags air that is too humid or too dry. High humidity risks condensation, and low humidity risks static discharge. |
| Altitude | fleetint_ | BMC altitude inventory reading — {sensor_context} reported {value} Pa. | This informational reading is not a threshold alert. It reports the altitude as inventory data, and altitude affects air-cooling capacity, so the reading helps explain cooling behavior. |
Logs
The collector reads event records, health reports, and firmware inventory from the BMC and reports them as logs. Each log has a type, a body, a severity, and attributes. Log collection depends on how you configure the Out-of-Band Collector.
BMC Log Entries and Events
The BMC records hardware events even when the host is down, so these logs show faults that the host never saw. The following table lists the logs that carry entries and events from the BMC.
| Log Type | Body | Severity | Attributes | Rationale |
|---|---|---|---|---|
| redfish_ | The message of a Redfish log entry. | FATAL for a Critical entry, WARN for Warning, INFO for OK, and TRACE for any other severity. | machine_ | Collects entries from the BMC log services, such as the system event log, on a recurring schedule. The entries give an audit trail for failure investigations. Collecting on a schedule works with any BMC that exposes log services. |
| redfish_ | The message of a Redfish event. | OK, Warning, or Critical, or another severity that the source reports. The value is Unknown when the event reports no severity. | message_ | Receives events from the BMC as they occur through the Redfish event stream, which uses Server-Sent Events (SSE). The collector learns about faults without waiting for the next poll. Each event identifies the resource that caused the condition. It can include a suggested resolution and a group identifier that links events with the same root cause. |
Health Reports
A health report summarizes the result of one group of BMC checks. Every health report log has the following format.
| Field | Value |
|---|---|
| Body | health report: <alerts> alerts, <successes> ok (source: <source>) |
| Severity | WARN when the report contains alerts, and INFO otherwise. |
| Attributes | event.type=health_report |
A tray is a serviceable enclosure within a rack-scale system. The leak detection reports apply to liquid-cooled systems whose BMCs expose leak detectors. The following table lists the health report logs by source.
| Log Type | Source | Description | Rationale |
|---|---|---|---|
| health_ | BmcSensors | Summarizes the alerts from BMC sensors. | Gives one record of how many sensors are in alert, so you can chart and alert on overall sensor health without reading each sensor alert. |
| health_ | BmcEvents | Summarizes the alerts that BMC events raise, such as an asserted chassis intrusion sensor. | Condenses the BMC event stream into a count of active alerts, so that a burst of events shows up as one signal. |
| health_ | BmcLeakDetectors | Summarizes the observations from the leak detectors that the BMC exposes. | Reports coolant leaks as the BMC sees them. A leak can damage hardware and create an electrical hazard, so it needs its own signal. |
| health_ | TrayLeakDetection | Summarizes the leak status of a tray, derived from the leak detector observations. | Rolls detector observations up to the tray, which is the unit that you service or remove from use after a leak. |
| health_ | RackLeakDetection | Summarizes the leak status of a rack. | A leak that affects several trays is a rack-level problem that needs a response beyond a single node. This report raises it as its own signal. |
Firmware Inventory
The following table lists the firmware inventory log.
| Log Type | Body | Severity | Attributes | Rationale |
|---|---|---|---|---|
| firmware_ | <component name>: <firmware version> | INFO | event.type=firmware | Records the firmware version of each component that the BMC reports, such as the BMC, the BIOS, and device firmware. It shows nodes that run different versions, confirms that an update took effect, and correlates faults with a firmware release. |
Log Attributes
The following table describes the attributes that the logs carry.
| Attribute | Description | Rationale |
|---|---|---|
| machine_ | Machine identifier, which is the same value that the in-band agent reports. | Joins the log with in-band data for the same node. |
| entry_ | Identifier of the Redfish log entry. | Traces a log back to its entry on the BMC and detects repeated entries. |
| service_ | Identifier of the Redfish log service that holds the entry. | Shows which BMC log produced the entry. |
| message_ | Identifier of the event message in a Redfish message registry. | Identifies the kind of event, so you can group and filter events without parsing the message text. |
| event_ | Type of the event. Redfish deprecated this property, and it appears when the BMC still reports it. | Preserves the event classification from BMCs that still use it. |
| event_ | Unique identifier of the event instance. | Separates one occurrence from another and supports deduplication. |
| event_ | Time that the event occurred, as the BMC reports it. | Orders events by when they happened rather than when the collector received them. |
| message_ | Arguments that the BMC substitutes into the message. | Provides the values behind the message text, such as the affected component, in a structured form. |
| message_ | Severity of the message in the event. | Supports filtering and alerting on severity. |
| origin_ | Link to the resource that originated the condition that caused the event. | Pinpoints the component that caused the event. |
| log_ | Identifier of the log entry that the BMC created for the event, if it created one. | Links an event to the matching entry in the BMC log, so you can cross-reference the two log types. |
| event_ | Identifier that correlates events with the same root cause. Redfish defines a value of 0 as no related events. | Groups related events so that one failure does not look like many unrelated problems. |
| resolution | Suggestion from the BMC on how to resolve the condition that caused the event. | Gives you a first action to take without looking up the event code. |
| event.type | Type of record. The value is health_report for health reports and firmware for firmware inventory. | Separates health reports and firmware inventory from other logs. |