Logging
The Holoscan SDK uses the Logger module to convey messages to the user. These messages are categorized into different severity levels (see below) to inform users of the severity of a message and as a way to control the number and verbosity of messages that are printed to the terminal. There are two settings which can be used for this purpose:
Logger level
Logger format
Logger Level
Messages that are logged using the Logger module have a severity level, e.g., messages can be categorized as INFO, WARN, ERROR, etc.
The default logging level for an application is to print out messages with severity INFO or above, i.e., messages that are categorized as INFO, WARN, ERROR, and CRITICAL.
You can modify this default by calling set_log_level()
(C++
/Python
) in the application code to override the SDK default logging level and give it one of the following log levels.
TRACE
DEBUG
INFO
WARN
ERROR
CRITICAL
OFF
#include <holoscan/holoscan.hpp>
int main() {
holoscan::set_log_level(holoscan::LogLevel::WARN);
// ...
return 0;
}
from holoscan.logger import set_log_level
def main():
set_log_level(LogLevel::WARN)
# ...
if __name__ == "__main__":
main()
Additionally, at runtime, the user can set the HOLOSCAN_LOG_LEVEL
environment variable to one of the values listed above.
This provides users with the flexibility to enable printing of diagnostic information for debugging purposes when
an issue occurs.
export HOLOSCAN_LOG_LEVEL=TRACE
Under the hood, Holoscan SDK uses GXF to execute the computation graph. By default, this GXF layer uses the same logging level as Holoscan SDK. If it is desired to override the logging level of this executor independently of the Holoscan SDK logging level, environment variable HOLOSCAN_EXECUTOR_LOG_LEVEL
can be used. It supports the same levels as HOLOSCAN_LOG_LEVEL
.
For distributed applications, it can sometimes be useful to also enable additional logging for the UCX library used to transmit data between fragments. This can be done by setting the UCX environment variable UCX_LOG_LEVEL
to one of: fatal, error, warn, info, debug, trace, req, data, async, func, poll. These have the behavior as described here: UCX log levels.
Precedence
If the HOLOSCAN_LOG_LEVEL
environment variable is set, this setting is used to set the logging level. If the
environment variable is not set, then the application setting is used if available. If not, the SDK default setting
of INFO is used as the logging level.
When a message is printed out, the default message format shows the message severity level, filename:linenumber, and the message to be printed.
For example:
[info] [ping_multi_port.cpp:114] Rx message value1: 51
[info] [ping_multi_port.cpp:115] Rx message value2: 54
You can modify this default by calling set_log_pattern()
(C++
/Python
) in the application code to override the SDK default logging format.
The pattern string can be one of the following pre-defined values
SHORT : prints message severity level, and message
DEFAULT : prints message severity level, filename:linenumber, and message
LONG : prints timestamp, application, message severity level, filename:linenumber, and message
FULL : prints timestamp, thread id, application, message severity level, filename:linenumber, and message
#include <holoscan/holoscan.hpp>
int main() {
holoscan::set_log_pattern("SHORT")
// ...
return 0;
}
from holoscan.logger import set_log_pattern
def main():
set_log_pattern("SHORT")
# ...
if __name__ == "__main__":
main()
With this logger format, the above application would display messages with the following format:
[info] Rx message value1: 51
[info] Rx message value2: 54
Alternatively, the pattern string can be a custom pattern to customize the logger format. Using this string pattern
"[%Y-%m-%d %H:%M:%S.%e] [%n] [%^%l%$] [%s:%#] %v";
would display messages with the following format:
[2023-06-27 14:22:36.073] [holoscan] [info] [ping_multi_port.cpp:114] Rx message value1: 51
[2023-06-27 14:22:36.073] [holoscan] [info] [ping_multi_port.cpp:115] Rx message value2: 54
For more details on custom formatting and details of each flag, please see the spdlog wiki page.
Additionally, at runtime, the user can also set the HOLOSCAN_LOG_FORMAT
environment variable to modify the logger format. The accepted string pattern is the same as the string pattern for
the set_log_pattern()
api mentioned above.
If the HOLOSCAN_LOG_FORMAT
environment variable is set, this setting is used to set the logger format. If the environment variable is not set, then the application setting is used if available. If not, the SDK default message format is used.
The C++ API uses the HOLOSCAN_LOG_XXX() macros to log messages in the application. These macros use the fmtlib format string syntax for their format strings.
Holoscan automatically checks HOLOSCAN_LOG_LEVEL
environment variable and sets the log level when the Application class instance is created.
However, those log level settings are for Holoscan core or C++ operator (C++)’s logging message (such as HOLOSCAN_LOG_INFO
macro), not for Python’s logging. Users of the Python API should use the built-in logging
module to log messages.
The user needs to configure the logger before use (logging.basicConfig(level=logging.INFO)
):
>>> import logging
>>> logger = logging.getLogger("main")
>>> logger.info('hello')
>>> logging.basicConfig(level=logging.INFO)
>>> logger.info('hello')
INFO:main:hello