Parallel Upgrades

View as Markdown

2.1 Introduction

In contrast with the in-place upgrade (Chapter 3), for a parallel upgrade the production cluster remains operational while the upgrade takes place. This is possible with the cm-clone-install and cm-upgrade functionality that allows the production (primary) head node to be cloned to a new node. The new node is upgraded (in parallel) outside of the cluster, and when the upgrade is completed, the old production primary head node is replaced with the (newly) upgraded head node. This last step to replace the head node will require a downtime.

Alternatively, the compute nodes can be gradually moved from the old production to the new parallel-upgrade setup, while the two setups co-exist.

2.2 Existing Cluster Health Check

It is a good idea to check that the existing cluster is in a healthy state before carrying out the upgrade.

The head nodes health checks in particular should be looked at. Unexpected health check failures should be examined, and if required, resolved. In some cases it is expected that health checks will be in a failed state. For example, if all the compute nodes are DOWN, then the schedulers health check fails.

The reason behind checking the health of the cluster before upgrading is that the health checks can detect failing services, overfull filesystems, unmounted filesystems, networking issues, time synchronization issues, and other issues. If these are unexpected then they can prevent the upgrade from completing successfully.

2.3 Preparations For The Parallel Upgrade Setup

The following steps need to be carried out for parallel upgrades. The steps marked with HA (High Availability) need to be carried out only on clusters with (head node) HA:

  • Have the BCM product key and the MAC address of the spare node (which is to be used for cloning the primary active head node) ready, since they will need to be provided while cloning the primary head node to the spare node. In an air-gapped cluster the product key is not provided while cloning. It is instead used later, when a license is requested separately.

  • (HA) Have also the MAC address of the secondary head node ready.

  • Have the new IPs for the cloned primary head node on the external network(s) ready.

  • (HA) The primary head node must be made the active head, if it is not already.

  • (HA) Login to the secondary passive head node and stop CMDaemon (systemctl stop cmd). Note: make sure to stop CMDaemon on the passive secondary head node, and not on the primary active head node.

  • (HA) On the same secondary passive head node, edit /etc/fstab and comment out the entry for /cm/shared, so that on the next boot the secondary passive head node does not mount /cm/shared from the file server.

  • (HA) Shut down the secondary passive head node. The node should remain shut down until later when plugged in to the parallel setup.

  • Plug the spare node to the internal network of the production cluster and PXE boot it to the BCM rescue environment (select RESCUE in the PXE boot menu, in the same way as performing a clone for an HA setup)

  • Log in to the rescue environment and run cm-clone-install, providing the product key and the MAC address of this spare node. In the case of HA, the MAC address of the secondary head node must also be provided. Thus, for the non-HA case:

    # /cm/cm-clone-install --clone --upgrade --productkey PRODUCT-KEY \
    --primarymac PRIMARY-MAC

    and for the HA case:

    # /cm/cm-clone-install --clone --upgrade --productkey PRODUCT-KEY \
    --primarymac PRIMARY-MAC --secondarymac SECONDARY-MAC

    and follow the instructions. At the end of the cloning process, confirm shutting down the spare node.

    In the preceding the values used for the primary and secondary MAC addresses are specified as follows:
    PRIMARY_MAC: the MAC address of the management interface of the primary head node (i.e the one that is on the management network)
    SECONDARY_MAC: the MAC address of the management interface of the secondary head node (i.e the one that is on the management network)

    In an air-gapped cluster the preceding commands cannot complete. A license is requested over the network once the disk sync and finalization stages have finished, and if the licensing service cannot be reached, then the request fails and the run stops before the final cleanup and shutdown stage. The clone is finalized on disk, but it is not prepared for shutdown, and it is therefore not ready to be moved to the parallel setup.

    For an air-gapped cluster the --skip-request-license option is therefore used in place of --productkey. No product key is given on the command line. Thus, for the non-HA case:

    # /cm/cm-clone-install --clone --upgrade --skip-request-license \
    --primarymac PRIMARY-MAC

    For the HA case, --secondarymac is added in the same way as previously.

    The remaining stages, including the cleanup and the confirmation to shut down the spare node, then run as described previously. The cloned head node runs without a license until one is installed on it. A license can be requested and installed separately, using the procedure for a cluster without WWW access. That procedure is described under Requesting A License With The request-license Script in the Installation Manual.

  • Unplug the spare node from the production setup/networks and plug it in the parallel setup.

  • In the case of /cm/shared on a file server (i.e. usually on an HA setup), login to the file server and make a copy of the /cm/shared to a new directory. Alternatively, the copy can be made to a new file server. Have the directory name and the (possibly new) file server host name ready.

  • Boot the spare (a.k.a. cloned primary head) node as it is plugged in the parallel (isolated) setup. The node will boot with all of its network interfaces remaining DOWN.

  • Login on console (ignoring possible messages about not-found modules in /cm/shared), and run /root/cm/update-cloned-db.py, providing the new location of /cm/shared:

    # /root/cm/update-cloned-db.py --new-cm-shared NEW-CM-SHARED-DIRECTORY-NAME \
    --nas-server NAS-SERVER

    which will setup in CMDaemon to mount the copy of /cm/shared made in the preceding session from NAS-SERVER:NEW-CM-SHARED-DIRECTORY-NAME

    or, if /cm/shared is not on a NAS server (i.e. no copy of /cm/shared was made in the preceding session), then just run:

    # /root/cm/update-cloned-db.py

    The script finds values for MAC addresses, interfaces, and so on that came as part of the original primary head node, and converts those values to ones suitable for the clone.

  • After /root/cm/update-cloned-db.py is completed, on the cloned primary head node still logged in on the console, by using “cmsh -r localhost”, change the IPs of the primary head node (master) on the external network(s).

  • In the case of HA: change also the shared IP (alias) of the secondary head node on the external network(s) to match the new shared IP(s) of the primary head node.

  • If necessary, update also other settings such as power management settings or if desired fsmounts, to reflect that in this parallel setup the primary head node is a different physical machine, which is a clone of the original primary head node.

  • Reboot, to allow for the settings to take effect. After the reboot, the (cloned) primary head node in the parallel setup will have the network interfaces UP.

  • Ensure that this primary head node in the parallel setup has correctly mounted the copied /cm/shared from the file server, if a copy of /cm/shared was made in the preceding.

    If /cm/shared is not correctly mounted, then verify the fsmount settings for the primary head node, the secondary head node, as well as for the compute nodes (typically the compute nodes fsmount settings are set in the compute nodes categories) are correct and the head node is able to connect to the file server.

  • (HA) Plug in the secondary head node to the parallel setup and boot it. After the secondary head node has booted, ensure it has mounted correctly the /cm/shared copy from the file server.

  • (HA) On both the (cloned) primary head node and the secondary head node, ensure the active head node is the (cloned) primary head node, the failover is in a good state and the mysql replication is working by running (on both head nodes):

    # cmha status

    If any of the returned responses for failoverping, mysql, ping, or status do not report “OK”, then ensure the network configuration and cabling allow the two head nodes in the parallel setup to communicate, and that they are isolated from the production setup. If this does not resolve the issue, then please contact support (https://enterprise-support.nvidia.com/s/create-case) for further assistance.

The notes in sections 2.4–2.8 should now be considered, before continuing on with the upgrade as described in sections 2.9– 2.10.

2.4 Important: Considerations For The Parallel Upgrade Setup

2.4.1 Configuration Changes And Services On The Production Cluster Desynchronized

The parallel upgrade procedure involves creating a clone of the primary head node and isolating the clone from the production cluster.

This means that after creating the clone of the primary head node, changes that are usually saved on the head node or in /cm/shared due to activities such as

  • any further configuration changes on the production cluster,

  • further collected monitoring data,

  • other changes in settings or data values, such as are caused by the running of jobs, or by new WLM jobs’ state data,

are not mirrored or synced to the cloned parallel head node, and are not mirrored or synced to the copy of the /cm/shared directory tree.

Similarly, services running on the original primary head node will also be started by the operating system on the cloned head node, but they will not be able to communicate with the production cluster nodes.

For example, if the cluster is running with Kubernetes integration, with only one control plane running on the head node, then the control plane on the production head node will continue to communicate with the worker nodes and maintain the Kubernetes cluster state. In the parallel setup, the Kubernetes control plane on the cloned head node cannot communicate with any node from the production cluster and will not be aware of the Kubernetes cluster state.

Therefore some special services running on the parallel-setup head node may not be able to take over from the respective services running on the production head node when the old production head node is to be shut down and the upgraded parallel-setup head node is to become the production head node. In these special cases, the administrator needs to take the necessary steps to migrate the services, or the administrator needs to perform an in-place upgrade.

2.4.2 Local Data On The Head Node Desynchronized

When the users’ home directories (/home) or other data are not on a file server, then the administrator will most commonly need to take the necessary steps to sync the latest changes in the users’ home, resp. other directories from the production setup to the parallel setup when the upgrade of the parallel setup is complete.

2.4.3 Dangling, Temporary, And Relocated Mounted Network File Systems

If the users’ home directories are on a file server, then a manual sync of the data as pointed in the preceding is unnecessary, however the administrator must be aware that except for /cm/shared as noted below, the head node(s) in the parallel setup will retain their fsmount settings also during the upgrade. This means that also during the upgrade the head nodes from the parallel setup will attempt to mount the network file systems. If this behavior is not desired, the administrator can configure the parallel-upgrade network and cabling in such a way so that the file server(s) are also isolated from the parallel setup. Alternatively, the administrator can modify the fsmount settings after the primary head node is cloned when it is booted for the first time as described below, so that the head nodes in the parallel setup do not mount these network file systems.

On the other hand, if mounting the network file systems on the head nodes in the parallel setup is required, for example so that users can log in and test the upgraded setup while the production setup is still operational in parallel, then the network configuration/cabling should allow the head node to access the file servers. When the file servers are on an external network, usually no additional steps will be required since the head nodes in the parallel setup will have full access to the external networks.

If the file servers are on the internal network(s) however, because by default the cloned head node retains the same internal network IPs, and because the parallel setup’s internal networks should be isolated from the production setup, by default the parallel-setup’s head nodes cannot access the file servers or any other device on the production-cluster’s internal network(s). Additional measures such as setting up intermediate servers or re-configuring the network settings will have to be taken to ensure the parallel-setup’s nodes can access the data on the file servers when needed, or to make sure they have access to a copy of the data on different (possibly temporary) file servers. Such configuration changes are beyond the scope of this document, for further information please contact support (https://enterprise-support.nvidia.com/s/create-case) for further assistance.

A special case is /cm/shared mounted from a file server. The clone and upgrade scripts will detect that, and the administrator will be required to copy /cm/shared to a new location and provide the (new) path and file server host name. The new location can be a new directory on the same file server if the file server is on an external network. If the file server is on the internal network, the simplest solution is to set up a new or temporary file server to host the required for the parallel upgrade copy of /cm/shared.

2.4.4 Cluster Extension Upgrade Not Supported

Parallel upgrade of clusters extended to the cloud (Cluster Extension cloudbursting) is not supported. For these clusters only an in-place upgrade is possible, which involves the termination of all cloud nodes when the cluster extension is removed as part of the upgrade procedure.

2.4.5 Edge Setup Upgrade Not Supported

Parallel upgrade of clusters with an edge setup is not supported.

2.4.6 Prerequisites

  • The cluster must have a previously installed and active subscription license.

  • A spare node is required for cloning the original (a.k.a production) primary head node. The spare node must have comparable to the current head node hardware, such as number of network cards, number of disks and size, memory, etc. After the completion of the upgrade, the spare node will become the new primary head node for the upgraded cluster.

  • In the case of head node HA, the secondary head node will need to be taken out of the production cluster so that it can also be upgraded. This means that for the time needed to perform the parallel upgrade, until all compute nodes are migrated to the upgraded setup, the old production cluster will run with only one head node.

  • If /cm/shared will be unmounted during the upgrade then please make sure that the contents of the local /cm/shared are in sync with the remote copy.

  • In the case of /cm/shared on a file server (such as in the case of head node HA), the file server must have enough space for creating a copy of the /cm/shared directory tree. Alternatively, /cm/shared can be copied to a new file server.

  • While performing the upgrade, the cloned primary and—in the case of HA—the secondary head node(s) need to have isolated internal network(s) which do not clash with the internal network(s) of the production cluster. The IP(s) of the upgraded head node(s) on the internal network(s) will remain the same. After the upgrade is completed, the old (not upgraded) primary head must be shut down and the upgraded head node(s) can be re-connected back in the cluster. Alternatively, compute nodes can be disconnected from the old (not upgraded) setup and then connected in the upgraded setup, which can also be performed gradually.

  • There is no requirement to isolate the external network(s) for the head node(s) while performing the upgrade, which means the cloned head node can still have access to the Internet. However, the cloned primary head node will require a new set of IPs on the external network(s), which are different from the current IP(s) of the primary head node on the external network(s). It is also recommended to use static IPs, and not DHCP with dynamic DNS updates on the external network, because both the original production head node and its clone in the parallel setup will have the same hostname as defined in CMDaemon. The secondary head node does not require a new set of IPs because it is simply moved (and not cloned) from the production to the parallel setup.

  • When upgrading the parallel setup, the head nodes require access to the new BCM package repositories. Alternatively, the BCM ISOs can be used as a source for the packages. Access to the base distro package repositories, using for example, the via internet or local repositories, is also required.

    Updates using the old BCM package repositories should be carried out only to bring the cluster up to date before running cm-upgrade.

  • In the case of HA, the cloned primary and the secondary head nodes will require to be able to connect to the file server for their copied /cm/shared directory tree. This means that if the file server is on an internal network, then—because the internal networks must be isolated—a new file server must be setup and made available on the isolated internal network.

2.5 Important: Upgrading Particular Applications

2.5.1 Overview Of The Applications That cm-upgrade Does And Does Not Manage

2.5.1.1 Automatically Upgraded By cm-upgrade

The following software, if managed by BCM 10, is managed and upgraded automatically by cm-upgrade to BCM 11:

  • Docker

  • The cm-docker-registry package (Harbor upgrades

    (section 2.5.6)

    are not supported)

  • Jupyter

    (the JupyterHub database requires some additional care (section 2.5.5)).

  • Base View: The regular version of Base View in BCM 10 is upgraded to a new version in BCM 11. Any monitoring dashboards from the regular BCM 10 Base View version are no longer used in the BCM 11 Base View version

    (section 2.5.2).

  • NVIDIA drivers: The defaults will be installed in non-DGX images

2.5.1.2 Automatically Kept As Is By cm-upgrade

The following applications are allowed to remain during the upgrade, and are not automaticaly upgraded:

2.5.1.3 Manually Removed And Reinstalled During Upgrade (Not Managed By cm-upgrade)

2.5.1.4 Removed From Support During Upgrade (Not Managed By cm-upgrade)

The following software is no longer managed by BCM in BCM version 11.

2.5.2 Upgrading Base View

BCM has Base View (section 2.4 of the Administrator Manual) as the browser GUI to carry out cluster management tasks. It is available as the package base-view.

Base View in BCM 10 had an additional, experimental and undocumented, Base View NG, available as the package base-view-ng. Base View NG uses a newer GUI toolkit from that of Base View in BCM 10.

Base View in BCM 11 is actually just a development of Base View NG from BCM 10, and so it uses that newer toolkit too.

The new Base View in BCM 11 means that an upgrade from BCM 10 to BCM 11 loses all the dashboards that users and administrators may have built for Base View in BCM 10.

It is therefore a good idea to make notes on the useful dashboards of BCM 10 so that analogous ones can be constructed for BCM 11. A useful transition may be to construct the analogues in Base View NG while still on BCM 10, before upgrading to BCM 11.

2.5.3 Upgrading Workload Managers (WLM)

Unsupported unversioned or unsupported versioned WLM packages are not removed automatically. They must be removed manually. If they are to be updated then it is recommended to install new, supported, versioned WLM packages.

The supported PBSPro versions are compatible across BCM 10 and BCM 11.

2.5.3.1 Upgrading WLMs In General From BCM 10

WLMs are not required to be disabled using cm-wlm-setup before upgrading the BCM version from 10 to 11.

2.5.3.2 Upgrading Slurm

Slurm versions older than Slurm 24.11 are not supported in BCM 11. When upgrading from BCM 10, Slurm must be upgraded to at least Slurm 24.11 in the BCM 10 repositories before moving to BCM 11.

Upgrading Slurm on a BCM 10 cluster is described in section 7.5 of the BCM 10 Administration Manual.

Packages:

Software images now include the same packages as the head nodes. This is because starting with BCM 11, Slurm packages keep many things in /cm/local, instead of /cm/shared.

Slurm client packages, for example slurm25.05-client, are no longer available. So they are removed as part of the upgrade procedure.

There are now separate slurmctld and slurmd packages that provide the binary and systemd unit files for each service.

Path adjustments: There are some path adjustments for Slurm for the upgrade from BCM 10 to BCM 11, as summarized in the following table.

Slurm itemVersionPath
Prefix directoryBCM10/cm/shared/apps/slurm
BCM11/cm/local/apps/slurm
Most configuration filesBCM10/cm/shared/apps/slurm/var/etc/
BCM11/cm/shared/apps/slurm/etc
Munge configuration filesBCM10/cm/shared/apps/slurm/var/etc/munge
BCM11/cm/shared/apps/slurm/var/etc/munge (unchanged)
BinariesBCM10/cm/shared/apps/slurm/current/bin
BCM11/cm/local/apps/slurm/current/bin
Template files such as: slurmdbd.conf.template, cgroup.conf.templateBCM10/cm/shared/apps/slurm/var/etc
BCM11/cm/local/apps/slurm/current/templates
statesave filesBCM10/cm/shared/apps/slurm/var/cm/statesave
BCM11/cm/shared/apps/slurm/statesave
Power scriptsBCM10/cm/shared/apps/slurm/var/cm/power
BCM11/cm/local/apps/slurm/current/scripts/power
Enroot prologBCM10/cm/shared/apps/slurm/var/cm
BCM11/cm/shared/apps/slurm/prologs/prolog-enroot.sh
Enroot epilogBCM10/cm/shared/apps/slurm/var/cm
BCM11/cm/shared/apps/slurm/epilogs/epilog-enroot.sh

2.5.3.3 Slurm DBD Performance Improvement

Installations from BCM 10.24.05 onward have MySQL configuration settings changes that improve the performance of the slurmdbd service. The changes are not automatically applied during updates of MySQL when updating from versions installed earlier than BCM 10.24.05.

To apply the improvement to a cluster that does not have this update, the MySQL configuration must be manually adjusted on the head nodes after cm-upgrade has completed. The /etc/my.cnf file on the head node, and also on the secondary head node in an HA-enabled cluster, should have the following settings updated:

innodb_buffer_pool_size=4096M
innodb_log_file_size=64M
innodb_lock_wait_timeout=900

The default my.cnf file is typically symlinked by the system utility update-alternatives in Ubuntu and SLES, (alternatives in RHEL derivatives), so how it is configured should also be considered.

2.5.3.4 Slurm Upgrades For DGX OS 6 To DGX OS 7

For DGX, BCM 10 supports only DGX OS 6 (an Ubuntu 22.04 variant), while BCM 11 supports DGX OS 7 (an Ubuntu 24.04 variant). Since BCM point release 11.34.0, BCM also supports DGX OS 8 (an Ubuntu 26.04 variant) for x86_64.

As part of the upgrade from BCM 10 to BCM 11, the DGX OS must be replaced with DGX OS 7. When replacing the DGX OS nodes from 6 to 7, a new software image (and /cm/shared) is created for the Ubuntu 2404 nodes.

If Slurm and Pyxis have been deployed in a BCM 10 DGX OS 6 image, then some manual configuration changes must be done to make these work right in the BCM 11 DGX OS 7 image. These can be carried out as follows:

Changes to the MUNGE key in /cm/shared: The key needs to have the correct permissions and ownership. If it does not have these, then a symptom of it is the message:

munged: Error: Keyfile is insecure: "/cm/shared/apps/slurm/var/munge/keys/
munge.key" should be owned by UID 1 instead of UID 0

as seen in the systemd status output:

root@dgx-04:~# systemctl status munge.service
× munge.service - MUNGE authentication service
Loaded: loaded (/usr/lib/systemd/system/munge.service; enabled;
preset: enabled)
Active: failed (Result: exit-code) since Fri 2025-10-31
03:54:29 PDT; 26s ago
Docs: man:munged(8)
Process: 255424 ExecStart=/usr/sbin/munged --key-file=/cm/shared/
apps/slurm/var/munge/keys/munge.key (code=exited, status=1/
FAILURE)Oct 31 03:54:29 dgx-04 systemd[1]: Starting
munge.service - MUNGE authentication service...
Oct 31 03:54:29 dgx-04 munged[255424]: munged: Error: Keyfile is insecure:
"/cm/shared/apps/slurm/var/munge/keys/munge.key" should be owned by UID 1
instead of UID 0
Oct 31 03:54:29 dgx-04 systemd[1]: munge.service: Control process exited,
code=exited, status=1/FAILURE Oct 31 03:54:29 dgx-04 systemd[1]:
munge.service: Failed with result 'exit-code'.
Oct 31 03:54:29 dgx-04 systemd[1]: Failed to start munge.service -
MUNGE authentication service.

The key can be made consistent with that of the previous deployment. This can be done by changing the attributes of the files in the new DGX software image, for example dgx-os-7.2-h100-image, after mounting it in the appropriate shared directory on the new cluster:

Example

cm-chroot-sw-img -s /cm/shared-ubuntu2404-x86_64 \
/cm/images/dgx-os-7.2-h100-image
...
chown daemon:root /cm/shared/apps/slurm/var/munge/keys/munge.key
chmod 400 /cm/shared/apps/slurm/var/munge/keys/munge.key

Changes to the Pyxis and Enroot files: The files within the DGX OS 7 image can be configured as follows:

Copy the Pyxis plugin file to the new software image, for example: dgx-os-7.2-h100-image:

Example

cp /cm/local/apps/slurm/current/lib64/slurm/spank_pyxis.so \
/cm/images/dgx-os-7.2-h100-image/cm/local/apps/slurm/current/lib64/slurm/

Copy the plugstack files in /cm/shared over from the Ubuntu 2204 (DGX OS 6) version to the Ubuntu 2404 (DGX OS 7) version:

Example

cp /cm/shared-ubuntu2204-x86_64/apps/slurm/etc/slurm/plugstack.conf \
/cm/shared-ubuntu2404-x86_64/apps/slurm/etc/slurm/
cp /cm/shared-ubuntu2204-x86_64/apps/slurm/etc/slurm/plugstack.conf.d/pyxis.conf \
/cm/shared-ubuntu2404-x86_64/apps/slurm/etc/slurm/plugstack.conf.d/

Copy the Enroot configurations in /cm/shared from the Ubuntu 2204 version to the Ubuntu 2404 version:

Example

cp /cm/shared-ubuntu2204-x86_64/apps/slurm/etc/enroot.conf \
/cm/shared-ubuntu2404-x86_64/apps/slurm/etc/
cp /cm/shared-ubuntu2204-x86_64/apps/slurm/etc/enroot-sysctl.conf \
/cm/shared-ubuntu2404-x86_64/apps/slurm/etc/

Symlinks for the epilog, prolog, and enroot.conf files are created for the new software image:

Example

cm-chroot-sw-img -s /cm/shared-ubuntu2404-x86_64 /cm/images/dgx-os-7.2-h100-image/
ln -s /cm/shared/apps/slurm/prologs/prolog-enroot.sh \
/cm/local/apps/slurm/var/prologs/50-prolog-enroot.sh
ln -s /cm/shared/apps/slurm/epilogs/epilog-enroot.sh \
/cm/local/apps/slurm/var/epilogs/50-epilog-enroot.sh
ln -s /cm/shared/apps/slurm/etc/enroot.conf /etc/enroot/enroot.conf
<ctrl-d>

The compute nodes can pick up the new configuration when they get rebooted.

2.5.4 Upgrading The Kubernetes Package

Kubernetes deployments do not need removal before upgrading to BCM 11. The same version of Kubernetes runs on the BCM cluster after the upgrade.

An upgrade to Kubernetes (section 4.22 of the Containerization Manual) can be carried out after the BCM upgrade.

2.5.4.1 Kubernetes Package Upgrades For DGX Software Images

When upgrading DGX OS nodes from 6 to 7.2, a new software image (and /cm/shared) needs to be created

(section 2.10.12),

for the nodes which will be running Ubuntu 24.04.

Kubernetes on the new DGX image needs to be manually copied over from the old image. This can be done as follows:

  • The kubernetes.list file should be copied over from the old image, <old DGX image>, to the new image, <new DGX image>, along with its associated keyring file:

    Example

    [root@basecm11 ~]# cp /cm/images/<old DGX image>/etc/apt/sources.list.d/\
    kubernetes.list /cm/images/<new DGX image>/etc/apt/sources.list.d/
    [root@basecm11 ~]# cp /cm/images/<old DGX image>/etc/apt/keyrings/\
    kubernetes-apt-keyring.gpg /cm/images/ <new DGX image>/etc/apt/keyrings/
  • The packages for the existing version need to be placed in the new image (here it is called new-dgx-image):

    [root@basecm11 ~]# cm-chroot-sw-img /cm/images/new-dgx-image
    ...
    [root@new-dgx-image /]# apt-get install cm-kube-diagnose kubeadm kubectl \
    kubelet kubernetes-cni cm-containerd nvidia-container-toolkit nginx \
    libnginx-mod-stream
    ...
  • The packages for the existing version need to be held. The following commands take care of that:

    [root@new-dgx-image /]# apt-mark hold kubeadm
    [root@new-dgx-image /]# apt-mark hold kubectl
    [root@new-dgx-image /]# apt-mark hold kubelet
    [root@new-dgx-image /]# <ctrl-d>

The is to exit out of the cm-chroot-sw-img directory. The cm-chroot-sw-img command is described here.

2.5.5 Upgrading The JupyterHub Database

The JupyterHub database schema must be manually upgraded in each JupyterHub node after the main package upgrade has completed. The following commands can be run to upgrade the JupyterHub database:

module load jupyter
jupyterhub upgrade-db--config=/cm/local/apps/jupyter/conf/jupyterhub_config.py \
--db sqlite:////cm/local/apps/jupyter/run/jupyterhub.sqlite

2.5.6 Upgrading The Docker Registry And Harbor Packages

Harbor cannot be upgraded when BCM 10 is upgraded to BCM 11, its package can only be (re-)installed and (re-)deployed separately from the BCM upgrade.

If the Harbor packages were installed in BCM 10 to a node other than the head node, then a re-deployment to that node is required after the upgrade to BCM 11 for Harbor.

When upgrading a cluster from BCM 10 to BCM 11 the upgrade of Docker registry is supported.

2.6 Important: Package Upgrade Dependency Issues

The upgrade process will not only upgrade CMDaemon and its dependencies, but it will also upgrade other packages. This means that old packages will not be available from the new BCM repositories.

In some cases, this will require recompiling the user applications to use the upgraded versions of the compilers and the libraries. Also, the configurations of the old packages will not be copied automatically to the new packages, which means that the administrator will have to adjust the configuration from the old packages to suit the new packages manually.

Extra base distribution packages may be installed by yum/zypper/apt-get in order to resolve dependencies that might arise as a result of the upgrade. Hence the base distribution repositories must be reachable. This means that the clusters that run the Enterprise Linux distributions (RHEL and SLES) must be subscribed to the appropriate software channels.

Packages in /cm/shared are upgraded, but the administrator should be aware of the following:

  • If /cm/shared is installed in the local partition, then the packages are upgraded. This may not be desirable for users that wish to retain the old behavior.

  • If /cm/shared is mounted from a separate partition, then unmounting it will prevent upgrades to the mounted partition, but will allow new packages to be installed in /cm/shared within the local partition. This may be desirable for the administrator, who can later copy over updates from the local /cm/shared to the remote /cm/shared manually according to site-specific requirements. Since unmounting of mounted /cm/shared is carried out by default, a local /cm/shared will have files from any packages installed there upgraded. According to the yum database, the system is then upgraded even though the files are misplaced in the local partition. However, the newer packages can only be expected to work properly if their associated files are copied over from the local partition to the remote partition.

2.7 Known Issues

2.7.1 Kubernetes PVC Access Issue With The Shared Directory For Multidistro (MultiOS)

With a multidistro Kubernetes cluster, there can be a known issue with accessing /cm/shared across the various nodes.

2.7.1.1 Under What Conditions Is There An Issue?

The issue can occur when all of the following conditions apply:

  1. The Kubernetes cluster (and worker nodes in particular) are spread across multiple DGX OS versions, due to one of the following situations:

    • (A) the nodes are running as multidistro nodes within the same Kubernetes cluster (running permanently as multidistro as is the intention, and not just transiently as part of an upgrade).

    • (B) the nodes are being upgraded, for example from Ubuntu 22 to Ubuntu 24

  2. The Local Path Provisioner is provisioned and deployed in the Kubernetes cluster. This is a component running in Kubernetes that enables pods in every Kubernetes node to consume some kind of local storage. The local-path-provisioner parameter provides the local path StorageClass, which sets up a sub-directory under /cm/shared.

  3. In this Kubernetes cluster, there is at least one pod using the local-path StorageClass using a PVC (PersistentVolumeClaim)

2.7.1.2 Why Is There An Issue?

The problem is that the /cm/shared directory is not unique across all nodes in a BCM cluster. The directory differs based on the DGX OS version. For example, on the head node, for the /cm/shared mount, you have:

  • for Ubuntu 22 nodes:

    /cm/shared-ubuntu2204-x86_64

  • for Ubuntu 24 nodes:

    /cm/shared-ubuntu2404-x86_64

During normal running, each DGX node only sees its specific /cm/shared.

Now, if a pod consuming a PVC from its local-path StorageClass is rescheduled to a node from the other DGX OS, then it cannot find the volume anymore, and it creates a new one.

2.7.1.3 Resolving The Issue For Persistent Mixed Distributions

A solution in the case of persistent mixed distributions on the nodes is to move all the pods to a new common shared directory for Kubernetes, independent of the directories offered for the specific DGX OS versions.

Steps:

  1. If the cluster is not HA, then

    • a new /cm/shared-kube directory can be created

    • a new fsexport is created on the headnode:

      Example

      [head]% device use master; fsexports
      [head->device[head]->fsexports*]% add /cm/shared-kube@internalnet
      [head->devi...*[/cm/shared-kube@internalnet*]]% set path /cm/shared-kube
      [head->devi...*[/cm/shared-kube@internalnet*]]% set network internalnet
      [head->devi...*[/cm/shared-kube@internalnet*]]% set write yes
      [head->devi...*[/cm/shared-kube@internalnet*]]% commit
      [head->device[head]->fsexports[/cm/shared-kube@internalnet]]%
  2. If the cluster is HA, then

    • a new directory or export can be created in the NAS to store the Kubernetes directory

    • if the headnode is a Kubernetes workers, or if the head node is a Kubernetes control-plane node that uses volumes using pods, then volumes will be used. Create an fsmount on the head nodes with:

      Example

      [head->device[head]->fsmounts]% add /cm/shared/apps/kubernetes
      [head->...red/apps/kubernetes*]]% set device 10.180.81.165:/brdkube
      [head->..*]->fsmounts*[/cm/shared/apps/kubernetes*]]% set filesystem nfs
      [head->device*[head*]->fsmounts*[/cm/shared/apps/kubernetes*]]% commit
  3. Create an fsmount in the Kubernetes worker nodes categories (and/or nodes):

    Example

    [head->category[default]->fsmounts]% add /cm/shared/apps/kubernetes
    [head->...red/apps/kubernetes]]% set device $localnfsserver:/cm/shared-kube
    [head->...*]->fsmounts*[/cm/shared/apps/kubernetes*]]% set filesystem nfs
    [head->...*]->fsmounts*[/cm/shared/apps/kubernetes*]]% commit
    [head->category[default]->fsmounts[/cm/shared/apps/kubernetes]]%
  4. Turn off all the Kubernetes worker nodes using cmsh

    This ensures that all pods are down, and not writing to the PVCs

  5. On the head node, populate the whole directory with all the data from Kubernetes:

    Example

    rsync -ar /cm/shared-ubuntu2204-x86_64/apps/kubernetes/ \
    /cm/shared/apps/kubernetes/
  6. If present, copy specific PVCs from Ubuntu 24.04 as well:

    Example

    rsync -ar /cm/shared-ubuntu2404-x86_64/apps/kubernetes/default/var/volumes/\
    /cm/shared/apps/kubernetes/default/var/volumes/
  7. Turn on all the Kubernetes worker nodes

  8. Ensure the Kubernetes worker nodes mount the new /cm/shared/apps/kubernetes directory

    Example

    mount | grep /cm/shared
  9. Ensure all the pods are up and running again:

    Example

    kubectl get pods -A
  10. Afterwards, clean up the old PVCs:

    Example

    rm -rf /cm/shared-ubuntu2204-x86_64/apps/kubernetes/default/var/volumes/
    rm -rf /cm/shared-ubuntu2404-x86_64/apps/kubernetes/default/var/volumes/

2.7.1.4 Resolving The Issue For The Upgrade Case Only

A solution in the case of an image upgrade, for example from DGX OS 6 to DGX OS 7, can be carried out as follows:

Before starting the upgrade of DGX OS version, you can move all PVCs from the old to the new /cm/shared.

We assume old nodes are running Ubuntu 22 and that they need to be upgraded to Ubuntu 24.

  1. Turn off all the (Ubuntu 22.04) Kubernetes worker nodes via cmsh

    This ensures that all pods are down and not writing to the PVCs.

  2. Upgrade DGX OS to Ubuntu 24.04

  3. On the head node, copy all the PVCs to the other new /cm/shared

    Example

    rsync -ar /cm/shared-ubuntu2204-x86_64/apps/kubernetes/default/var/volumes/ \
    /cm/shared-ubuntu2404-x86_64/apps/kubernetes/default/var/volumes/
  4. Turn on all the Kubernetes worker nodes and check that all the pods are up and running again (kubectl get pods -A)

  5. Afterwards, clean up the old PVCs:

    Example

    rm -rf /cm/shared-ubuntu2204-x86_64/apps/kubernetes/default/var/volumes/

2.7.1.5 Resolving The Issue If You Already Have Duplicated PVCs

A solution in the case of PVCs that have already been duplicated requires some finesse.

  1. Detect all PVCs in the old and new /cm/shared and mapping between them. First look for current PVCs and ensure each one has the related directory in the new shared directory:

    • kubectl get pvc -A

    • ls /cm/shared-ubuntu2404-x86_64/apps/kubernetes/default/var/volumes/

  2. Turn off the nodes

  3. Backup or move the newly created PVCs, that most likely should be deleted:

    Example

    mv /cm/shared-ubuntu2404-x86_64/apps/kubernetes/default/var/volumes \
    /cm/shared-ubuntu2404-x86_64/apps/kubernetes/default/var/volumes-backup
  4. Now, for each PVC, you have to find the original/correct one in the former shared directory. This is a manual process, and a bit of an art. You can consider:

    • The directory name which matches the Kubernetes namespace and PVC name

    • If there are 2 or more matching directories then:

      • look for the latest modification date (ls -lah)

      • check the overall size (du -hs). Usually the largest directory has more data and should be the most recent one

  5. Run an rsync command per PVC:

    Example

    rsync -ar \
    /cm/shared-ubuntu2204-x86_64/apps/kubernetes/default/var/volumes/\
    pvc-98975be7-4030-4f11-8680-46a38829e2e7_runai-backend_data-runai-backend-\
    redis-queue-master-0/ \
    /cm/shared-ubuntu2404-x86_64/apps/kubernetes/default/var/volumes/\
    pvc-98975be7-4030-4f11-8680-46a38829e2e7_runai-backend_data-runai-backend-\
    redis-queue-master-0/

    Note: the source and target directories are different (...-ubuntu2204-... to ...-ubuntu2404-...). This is because the source should match what you have found out in the previous step, while the target should match what you listed initially.

  6. Turn on nodes and verify pods are up and running

2.7.2 Miscellaneous Known Issues

  • On clusters with Jupyter deployed, after the upgrade, users might find themselves being asked to login twice. The first time when the user will be asked to login to JupyterHub, and a second time, where the user is asked about a “CMDaemon login”. In such cases, the user should once again present the credentials. This extra login request is harmless, and after the credentials are given a second time, it is unlikely that users will be queried again. The cause of this issue is that the Jupyterhub component that interacts with CMDaemon can lose connection to CMDaemon, causing it to prompt for an extra login.

  • On some base distributions, depending on the version of the installed packages, when starting cm-upgrade, a YAMLLoadWarning message may be printed when its configuration files are loaded. The warning message can be safely ignored.

  • In some cases because /cm/shared may be temporarily not accessible from the cloned primary head node when it boots for the first time, if workload managers are setup on the cluster, then CMDaemon may create and leave module files called no-version. For example:
    slurm/slurm/no-version
    To resolve the issue, the leftover no-version module files under /cm/shared/modulefiles/ can be deleted.

  • In some cases at the end of the head node or the software image(s) upgrade, the cm-upgrade script may report a list of packages that were not upgraded to their BCM 11 versions. This can occur in cases where the package manager was not able to resolve the list of packages to find a suitable candidate at the time of the upgrade of all packages.

    While cm-upgrade makes a best effort to swap or upgrade the packages to their BCM 11 versions, in some cases— notably on Ubuntu, it is also possible some packages are left in their 10.0 versions.

    The administrator is advised to manually swap the cm10.0 packages with the cm11.0 package.

  • On clusters with cluster extension to AWS deployed, the cloud director and cloud nodes might fail to start after the upgrade. This can happen when there is an entry

    <blockdev mode="cloud">/dev/nvme1n1</blockdev>

    in the disksetup. The issue can be resolved by removing that entry from the disksetup for the cloud director and cloud nodes.

  • On clusters that have PBSPro configured, and upgraded from BCM 10 to BCM 11, new jobs submitted by users will get job ids that were already used. This is particularly relevant for users that use BCM monitoring data for billing purposes.

  • Disabling Kubernetes as part of the parallel-upgrade procedure results in an apparent failure during the stage when etcd data is cleaned up, because the compute nodes are not reachable from the parallel setup. This is expected since the parallel setup is isolated from the production setup. To resolve the issue, the administrator should answer a prompt so that the failed stage is skipped. It is also recommended to re-provision the compute nodes of the upgraded parallel setup before attempting to set up Kubernetes or etcd again, so that any leftover data from before the upgrade is cleaned during the provisioning.

  • When upgrading the DGX OS 6 sofware image to the latest updates of DGX OS 6, there is a known issue with DKMS when a new kernel linux-image-5.15.0-1090-nvidia is installed. The DKMS post-install script fails for the new kernel. This is caused by duplicate entries for the gdrdrv module. This can be checked for with the following command:

    root@dgx-os-6:/# dkms status
    gdrdrv/2.4.4, 5.15.0-1063-nvidia, amd64: installed
    gdrdrv/2.4.4, 5.15.0-1090-nvidia, amd64: installed
    gdrdrv/2.4.4, 5.15.0-1090-nvidia, x86_64: built

    The last two statuses are for the same driver, and the last line is built rather than installed, which means it was not installed, and leads to the post-install script failure.

    This issue can be resolved by removing the duplicate entry and reconfiguring the package as follows:

    dkms remove gdrdrv/2.4.4 -a amd64 -k 5.15.0-1090-nvidia
    dpkg --configure -a
  • When checking if the compute nodes are UP, in some cases cm-upgrade may wrongly report that some nodes are not DOWN. The report depends on how a node has been shut down, the state of the node not being updated correctly in the CMDaemon database. In such scenarios, after confirming that the nodes are indeed DOWN, re-run cm-upgrade with the --skip-node-states-check flag to skip the check for node states:

    Example

    cm-upgrade --skip-node-states-check
  • Upgrading from BCM 10 to BCM 11 for DGX SuperPOD deployments requires filesystem exports to be explicitly set for the network dgxnet (here).

  • The BCM machine learning repositories may still be referenced in the repository lists. They should be removed. For example, in the Ubuntu head node and images with:

    rm /etc/apt/sources.list.d/cm-ml.list

2.8 Upgrading Using A BCM DVD/ISO

When using a BCM DVD/ISO to perform the upgrade, it is important to use a DVD/ISO that is not older than 11.30.0. The DVD/ISO version can be found (assuming that the DVD/ISO is mounted under /mnt/cdrom) with a find command such as:

# find /mnt/cdrom -type d -name '11.30.0'
/mnt/cdrom/data/packages/11.30.0

2.9 Enable Upgrade

2.9.1 Enable The Upgrade Repo, And Install The Upgrade Package

Enabling the upgrade repository and installing the upgrade package can be carried out for the various distributions as follows:

RHEL8 derivatives:

# yum-config-manager \
--add-repo http://support.brightcomputing.com/upgrade/11.0/rhel/8/updates
# yum --nogpgcheck install cm-upgrade

RHEL9 derivatives:

# yum-config-manager \
--add-repo http://support.brightcomputing.com/upgrade/11.0/rhel/9/updates
# yum --nogpgcheck install cm-upgrade

SLES 15:

# zypper addrepo \
http://support.brightcomputing.com/upgrade/11.0/sles/15/updates cm-upgrade-11
# zypper install cm-upgrade

Ubuntu 22.04:

# cat <<EOF > /etc/apt/sources.list.d/cm-upgrade-11.list
deb [trusted=yes] https://support.brightcomputing.com/upgrade/11.0/ubuntu/2204/ ./
EOF
# apt update
# apt install cm-upgrade

Ubuntu 24.04:

# cat <<EOF > /etc/apt/sources.list.d/cm-upgrade-11.list
deb [trusted=yes] https://support.brightcomputing.com/upgrade/11.0/ubuntu/2404/ ./
EOF
# apt update
# apt install cm-upgrade

2.9.2 Load The Environment Module

# module load cm-upgrade

2.10 Perform Upgrade

The steps for carrying out the upgrade are as follows:

2.10.1 Apply Updates To Head Node

  • RHEL derivatives:

    # yum update
  • SLES derivatives:

    # zypper up
  • Ubuntu:

    # apt-get update
    # apt-get upgrade --with-new-pkgs

2.10.2 Apply Updates To Software Images

Before updating and upgrading a software image, it may be worth creating an image backup by cloning the image (here). If the cluster after the upgrade has an image that has an issue, then comparing it against the backup can help troubleshoot the issue.

For each software image, updates can be applied as follows:

  • RHEL derivatives:

    # yum --installroot /cm/images/<software image> update
  • SLES derivatives:

    # zypper --root /cm/images/<software image> up
  • Ubuntu:

    # cm-chroot-sw-img /cm/images/<software image>
    # apt-get update
    # apt-get upgrade --with-new-pkgs
    # exit

2.10.3 Apply Updates To The node-installer Image

  • RHEL derivatives:

    # yum --installroot /cm/node-installer update
  • SLES derivatives:

    # zypper --root /cm/node-installer up
  • Ubuntu:

    # cm-chroot-sw-img /cm/node-installer
    # apt-get update
    # apt-get upgrade --with-new-pkgs
    # exit

2.10.4 Upgrade Head Nodes To BCM 11

Important: this must be run on both head nodes in a high availability setup. Recommended: Upgrade the active head node first and then the passive head node.

Depending on availability, the upgrade can be run either over the network, or using a DVD/ISO:

  • Upgrade using repositories accessible over the network

    # cm-upgrade
  • Upgrade using a BCM DVD/ISO

    # cm-upgrade -b /root/bcm-11.0-ubuntu2404.iso

In an HA setup, after upgrading both the head nodes, resync the databases. Run the following from the active head node (it is very important to complete this step before moving to the next one):

# cmha dbreclone <passive>

2.10.5 Reboot Head Node(s)

The head node(s) must be rebooted before proceeding to run the post-upgrade actions.

2.10.6 Post-upgrade Head Node Actions

Important: these must be run on both head nodes in an HA setup

# module load cm-upgrade/11
# cm-post-upgrade -m

2.10.7 Upgrade The Software Image(s) To BCM 11

Important: the upgrade to the software images must be done only on the active head node. Depending on availability, the upgrade can be run either over the network, or using a DVD/ISO:

  • Upgrade using repositories accessible over the network

    # cm-upgrade -i all
  • Upgrade using a BCM DVD/ISO

    # cm-upgrade -i all -b /root/bcm-11.0-ubuntu2404.iso

If the software images are not under the standard location—/cm/images/ on the head node—then the option -a should be used:

# cm-upgrade -a /apps/images -i <name of software image>
# cm-upgrade -a /apps/images -i <name of software image> \
-b /root/bcm-11.0-ubuntu2404.iso

If the software images are located under multiple locations, the target locations can be specified as a comma-separated list:

# cm-upgrade -a '/apps/images,/opt/images' -i all

2.10.7.1 Btrfs Image Upgrades

If the software image is a Btrfs image, then the revision (section 14.4 of the Administrator Manual) images cannot be used, because they use read-only filesystems. This issue extends to all references in category or node images, such as @latest and @number

Only the original, unrevisioned, parent image can be upgraded with the cm-upgrade and cm-post-upgrade steps with a Btrfs filesystem.

A workaround would be to create a new non-CoW image from a trusted revision, and upgrading that trusted non-CoW version.

2.10.8 Upgrade /cm/node-installer To BCM 11

This needs to be performed only on the primary active head node, either over the network, or using a BCM DVD/ISO.

  • Upgrade using repositories accessible over the network:

    # cm-upgrade -x
  • Upgrade using a BCM DVD/ISO:

    # cm-upgrade -x -b /root/bcm-11.0-ubuntu2404.iso

2.10.9 Post-upgrade Software Images Actions

Important: these must be run only on the active head node.

# cm-post-upgrade -i all

If the software images are not under the standard location, which is /cm/images/ on the head node, then the option -a should be used:

# cm-post-upgrade -a /apps/images -i all
# cm-post-upgrade -a /apps/images -i <name of software image>

If the software images are located under multiple locations, then the target locations can be specified as a comma-separated list:

# cm-post-upgrade -a '/apps/images,/opt/images' -i all

2.10.10 NVIDIA Driver Installation

During the upgrade to BCM 11.0, cm-upgrade automatically installs NVIDIA GPU drivers on non-DGX software images. This is only carried out on software images. It is not carried out on the head nodes or the node-installer images.

2.10.10.1 Default NVIDIA Driver Version

By default, cm-upgrade installs NVIDIA driver version 570 (Open Kernel Modules edition). The following components are installed:

  • On Ubuntu 22.04 and 24.04: the package installed is the nvidia-driver-570-open meta-package plus additional components including:

    • Fabric Manager (for NVLink/NVSwitch management)

    • NSCQ library (NVIDIA NVSwitch Configuration and Query Library)

    • IMEX library (GPU memory sharing across different compute nodes in a multi-node system connected by NVLink)

    • NVSDM library (for monitoring NVSwitch devices on NVIDIA Blackwell systems)

  • On RHEL 9/Rocky 9: a comprehensive set of packages based on the major 570 version. The package set installed includes:

    • DKMS and open kernel modules for dynamic kernel support

    • Core driver libraries and CUDA components

    • Fabric Manager for multi-GPU interconnect management

    • GUI tools (nvidia-settings, nvidia-xconfig) for X11 display configuration

    Most package names are generic (for example: nvidia-driver, nvidia-fabric-manager), with the exact version version determined by the repository configuration

  • On SLES 15 SP6: the package installed is a set based on the major 570 version, and includes:

    • Open kernel modules (nvidia-open-570)

    • Fabric Manager and NSCQ library

    Packages are sourced from NVIDIA’s CUDA repository (version-numbered). Native SLES packages use G06 generation naming, but we use NVIDIA’s CUDA repository for consistency

2.10.10.2 Non-DGX Systems Only

NVIDIA driver installation is only carried out on non-DGX systems.

DGX systems have pre-installed NVIDIA drivers, which are maintained by NVIDIA’s own update mechanisms, and should not managed by cm-upgrade. The upgrade script detects DGX systems by checking for the presence of /etc/dgx-release in the software image. If this file exists, then NVIDIA driver installation in the DGX system is skipped.

2.10.10.3 Changing the NVIDIA Driver Version

If you need to install a different version of the NVIDIA drivers, then you can modify the driver version either before or after the upgrade as follows:

  • Pre-upgrade: Edit /cm/local/apps/cm-upgrade/11.0/conf/packages.yaml and modify the package versions listed under the nvidia_driver_packages section for your distribution.

  • Post-upgrade: Use the standard package management tools (yum/apt/zypper) within the software image to remove the installed driver packages and install your preferred version.

2.10.11 (HA) Allow For The Provisioning Requests To The Secondary Head Node To Complete

Allow between 15 and 30 seconds for CMDaemon to schedule and start provisioning updates of /tftpboot and /cm/node-installer from the primary to the secondary head node. Then check and wait until the provisioning requests with the secondary head node as destination have completed using:

# cmsh -c 'softwareimage provisioningstatus -r'

If the provisioning requests with a destination node the secondary head node continue to be listed for a prolonged period of time and do not disappear from the list, then the node-installer and/or tftpboot on the secondary head node are out of sync from the primary head node, which can result in issues with provisioning of the compute nodes. Please contact support (https://enterprise-support.nvidia.com/s/create-case) for further assistance.

2.10.12 Enable Mixed OS Setup And Create A DGX OS 7 Image

On BCM 10 Ubuntu 22.04 clusters can use DGX OS 6 images. DGX OS 6 images are not supported in BCM 11.

A new DGX OS 7 software image must therefore be used. The image can be created using cm-image and cm-create-image. These are BCM utilities, and are described in section 9.6 of the Administrator Manual.

DGX OS 7 is based on Ubuntu 24.04. This then also means the mixed OS environment—multidistro or multiOS as described in section 9.7 of the Administrator Manual—must be enabled, to allow provisioning of DGX OS 7 images from the Ubuntu 22.04 head node of BCM 10.

Image creation can be carried out as follows:

  1. A script may need to be created first:

    Example

    [root@basecm11 ~]# cat disable-upstream-repos.sh
    #!/bin/bash
    if [ -f "$1/etc/apt/sources.list.d/ubuntu.sources" ]; then
    mv $1/etc/apt/sources.list.d/ubuntu.sources \
    $1/etc/apt/sources.list.d/ubuntu.sources.dvd_bak
    fi

    The script is only needed for a cluster running a BCM version 11 earlier than 11.31.0. It works around a known issue that may arise from using an upstream repository in an inappropriate manner. For BCM 11.31.0 and later, the workaround is carried out automatically, and the script is not needed.

  2. Use cm-image to create the appropriate the Ubuntu 24.04 base images and enable a mixed OS setup. The -z option that calls the script need only be used for BCM 11 installations earlier than BCM 11.31.0.

    Example

    [root@basecm11 ~]# module load cm-image
    [root@basecm11 ~]# cm-image --v create all -a x86_64 -d ubuntu2404 --source
    /path/to/bcm11.0-ubuntu24.04-dgx-os-7.2.iso \
    -z disable-upstream-repos.sh
  3. Use cm-create-image to create the new DGX OS image. The -z option that calls the script need only be used for BCM 11 installations earlier than BCM 11.31.0.

    [root@basecm11 ~]# cm-create-image --cmdvd \
    /root/bcm-11.0-ubuntu2404-dgx-os-7.2.iso \
    --no-cm-cuda-repo --extra-pkg-group \
    doca_ofed_2.9.1-3.0.2 --dgx --dgx-type dgx_b200 \
    --imagename dgx-os-image-b200 \
    -z disable-upstream-repos.sh

The --dgx-type option (here) must be set for every type that is to be used as an image. The possible values are:

  • dgx_h100 for the H100 GPU

  • dgx_b200 for the B200 GPU

  • dgx_a100 for the A100 GPU

  • dgx_gb200 for the GB200 GPU

  • dgx_h200 for the H200 GPU

  • dgx_gb300 for the GB300 GPU

  • dgx_b300 for the B300 GPU

The cluster administrator should create a new category for each new image. Cloning the default-image image from the default category is a convenient way to do this since it already has the correct fsmounts. The image name should then be set for the category.

For example, for a B200 image dbx-os-image-b200 that has been placed in /cm-images/:

Example

root@basecm11:~# cmsh
[basecm11]% category
[basecm11->category]% list
Name (key) Software image Nodes
------------------------ ------------------------ --------
default default-image 1
[basecm11->category]% clone default gb200
[basecm11->category*[gb200*]]% use gb200
[basecm11->category*[gb200*]]% set softwareimage dgx-os-image-b200 ; commit
...

The nodes that are to use the new image should then be assigned their image. For example, a node001 can be assigned to the gb200 category created in the preceding example with:

Example

[basecm11->device]% set node001 category gb200 ; commit

Configuration overlays that were used in the old category should also be migrated as needed to the new category.

Upgrading from BCM 10 to BCM 11 for DGX SuperPOD deployments requires NFS exports to be explicitly set for the network dgxnet, for /cm/node-installer-ubuntu2404-x86_64 and /cm/node-installer-ubuntu2404-x86_64/certificates.

This can be configured with the following cmsh session on the head node:

Example

[root@basecm11 ~]# cmsh
[basecm11]% device use master
[basecm11->device[basecm11]]% fsexports
[basecm11->...->fsexports]% add /cm/node-installer-ubuntu2404-x86_64@dgxnet
[basecm11->...installer-ubuntu2404-x86_64@dgxnet*]]% set network dgxnet
[basecm11->...installer-ubuntu2404-x86_64@dgxnet*]]% commit
[basecm11->...installer-ubuntu2404-x86_64@dgxnet]]% ..
[basecm11->...rts]% add /cm/node-installer-ubuntu2404-x86_64/certificates@dgxnet
[basecm11->...-ubuntu2404-x86_64/certificates@dgxnet*]]% set network dgxnet
[basecm11->...-ubuntu2404-x86_64/certificates@dgxnet*]]% set write yes
[basecm11->...-ubuntu2404-x86_64/certificates@dgxnet*]]% commit
[basecm11->...-ubuntu2404-x86_64/certificates@dgxnet]]%

The same procedure must also be carried out for that secondary head node.

The new DGX OS image has no Kubernetes packages installed on it by default. Migrating an old Kubernetes installation over from the old image is described here.

2.10.13 Upgrading CMDaemon Lite

The BCM 10 to BCM 11 upgrade supports CMDaemon Lite (section 2.6.7 of the Administrator Manual) running on cluster switches, such as Cumulus switches.

After the upgrade has been carried out on the head node and the images are ready for deployment, then the switches can be rebooted to pick up their new image.

  • It is important not to reboot the switch that is being used to connect to the head node.

After the switches have rebooted, the compute nodes can be powered on.

In a cluster, mixing deployments of cm-lite-daemon for BCM 10 with those of BCM 11 is not supported.

This means that the CMDaemon Lite servers that are not managed by CMDaemon, for example PCs running CMDaemon Lite in a Python environment, also need to be upgraded when upgrading the cluster itself from BCM 10 to BCM 11. That must be done manually, by removing the BCM 10 package, and installing the BCM 11 package according to the environment and OS it is running in.

2.10.14 The Cluster Is Now Upgraded To BCM 11

It is recommended to provision the compute nodes at least once with BCM 11 before setting up any new integrations.

2.11 Simple Validation Checks

Some basic checks can be carried out to validate the cluster. If a check fails, then further investigation should be carried out.

2.11.1 Validating CMDaemon

The CMDaemon service status (section 2.6.1 of the Administrator Manual), can be checked with:

Example

root@basecm11:~# systemctl status cmd
● cmd.service - BCM daemon
Loaded: loaded (/usr/lib/systemd/system/cmd.service; enabled; preset: enabled)
Active: active (running) since Mon 2025-12-01 01:44:17 PST; 6h ago
Main PID: 2547 (safe_cmd)
Tasks: 77 (limit: 65535)
Memory: 576.1M (high: 3.4G max: 3.6G available: 1.3G peak: 600.1M)
CPU: 6min 56.963s
CGroup: /system.slice/cmd.service
...

2.11.2 Validating High Availability

If the cluster has HA configured, then the cluster manager HA status (here), can be checked. For example, for head nodes basecm11-a and basecm11-b the response to the check would be:

Example

root@basecm11-a:~# cmha status
Node Status: running in active mode
basecm11-a* -> basecm11-b
failoverping [ OK ]
mysql [ OK ]
ping [ OK ]
status [ OK ]
basecm11-b -> basecm11-a*
failoverping [ OK ]
mysql [ OK ]
ping [ OK ]
status [ OK ]

2.11.3 Validating cmsh And Devices

A check on the device statuses can be run with:

Example

root@basecm11:~# cmsh -c "ds"
basecm11.............[ UP ]
node001 .............[ UP ]
...

2.11.4 Validating The Cluster Health

Health check values can be retrieved from devices in the BCM monitoring system with the help of the latesthealthdata command (section 10.6.3.1 of the Administrator Manual):

Example

[basecm11->device]% foreach -v * (latesthealthdata)
================================= basecm11 =====================================
Measurable Parameter Type Value Age State Info
------------------ ------------ ------------ ---------- ---------- ---------- ----------
ManagedServicesOk Internal PASS 1m 39s
chrootprocess OS PASS 1.23s
cm-chroot-sw-img OS PASS 1m 18s
cmsh Internal PASS 25m 7s
cuda-dcgm OS PASS 54.8s
defaultgateway Network PASS 1m 8s
diskspace Disk PASS 14s
dmesg OS PASS 1m 51s
exports Disk PASS 9.21s
interfaces Network PASS 1m 7s
ldap OS PASS 1m 37s
lustre Disk PASS 58.8s
mounts Disk PASS 1m 40s
mysql OS PASS 53m 47s
ntp Internal PASS 1m 49s
oomkiller OS PASS 18s
ssh2node network PASS 8m 58s
================================= node001 =====================================
Measurable Parameter Type Value Age State Info
------------------ ------------ ------------ ---------- ---------- ---------- ----------
ManagedServicesOk Internal PASS 2m 54s
cuda-dcgm OS PASS 2m 9s
defaultgateway Network PASS 2m 13s
diskspace Disk PASS 3m 28s
dmesg OS PASS 3m 5s
interfaces Network PASS 2m 22s
ldap OS PASS 2m 51s
lustre Disk PASS 2m 13s
mounts Disk PASS 2m 55s
ntp Internal PASS 3m 3s
oomkiller OS PASS 1m 32s
ssh2node network PASS 8m 43s
...

2.11.5 Validating Base View

For a dotted quad IP address <IP address>, the cluster administrator can connect to:

https://<IP address>:8081/base-view

and try logging in. If there was non-administrator access before the upgrade, then that should also be checked.

2.11.6 Validating The State Of The Packages On The Cluster

The state of packages according to the package manager for the cluster can be checked in the head nodes and in the software images with:

2.11.6.1 Ubuntu Packages

apt-get check
dpkg --audit

2.11.6.2 RHEL-like Distribution Packages

yum check
rpm -Va --nofiles

2.11.6.3 SLES Packages

zypper verify
rpm -Va --nofiles

These commands should all normally give no output, other than processing messages in some cases.

2.11.7 Validating Slurm And Pyxis

Slurm and Pyxis validation on the cluster (here), can be carried out as follows:

2.11.7.1 Validating Slurm

root@basecm11:~# module load slurm
root@basecm11:~# scontrol show config
Configuration data as of 2025-12-02T04:06:05
AccountingStorageBackupHost = (null)
AccountingStorageEnforce = none
AccountingStorageHost = master
AccountingStorageExternalHost = (null)
AccountingStorageParameters = (null)
AccountingStoragePort = 6819
...
Slurmctld(primary) at basecm11 is UP

2.11.7.2 Validation Of Pyxis

root@basecm11:~# srun --container-image=ubuntu grep PRETTY /etc/os-release
pyxis: importing docker image: ubuntu
pyxis: imported docker image: ubuntu
PRETTY_NAME="Ubuntu 24.04.3 LTS"
root@basecm11:~#

2.11.8 Validating Kubernetes

The kube-system pods should be inspected to see if they are running along without any real issues:

Example

root@basecm11:~# kubectl get pods -n kube-system
NAME READY STATUS RESTARTS AGE
coredns-66bc5c9577-bv577 1/1 Running 0 4h24m
coredns-66bc5c9577-rsfpv 1/1 Running 0 4h24m
kube-apiserver-basecm11 1/1 Running 0 4h19m
kube-apiserver-node001 1/1 Running 2 4h24m
kube-controller-manager-basecm11 1/1 Running 0 4h23m
kube-controller-manager-node001 1/1 Running 2 4h25m
kube-proxy-2ckqr 1/1 Running 0 4h24m
...
kube-scheduler-node001 1/1 Running 1 4h25m
kube-state-metrics-6b98df4478-nhkd2 1/1 Running 0 4h19m
metrics-server-f49fdc486-4ndfk 1/1 Running 0 4h19m
metrics-server-f49fdc486-5rvbf 1/1 Running 0 4h19m

Are the operators running along fine too?

root@basecm11:~# kubectl get pods --all-namespaces
NAMESPACE NAME READY STATUS RESTARTS AGE
calico-system calico-apiserver-577cdf67b5-645qn 1/1 Running 0 4h49m
...
calico-system calico-typha-6495c7469f-gpztc 1/1 Running 0 4h49m
calico-system calico-typha-6495c7469f-rp9rz 1/1 Running 0 4h49m
calico-system goldmane-7b6b78f6f-tn65t 1/1 Running 0 4h49m
calico-system whisker-6c95b488ff-7s9pf 2/2 Running 0 4h49m
cm local-path-provisioner-675dc9fd86-b6fg6 1/1 Running 0 4h48m
cmkpm-system cmkpm-controller-manager-66b99b6699-6k6gm 1/1 Running 0 4h48m
grafana grafana-grafana-operator-c65d95b7f-c5p59 1/1 Running 0 4h47m
ingress-nginx ingress-nginx-controller-68994db546-7c2h9 1/1 Running 0 4h44m
ingress-nginx ingress-nginx-controller-68994db546-p6pjv 1/1 Running 0 4h44m
kube-system coredns-66bc5c9577-bv577 1/1 Running 0 4h51m
...