Firmware update NVLink Domains

View as Markdown

Update firmware for one or more NVLink Domains identified by UUID. Flow resolves each NVLink Domain to its member Racks and creates one task per Rack.

Org must have an Infrastructure Provider entity. User must have authorization role with PROVIDER_ADMIN suffix.

Authentication

AuthorizationBearer
``` export JWT_BEARER_TOKEN="<jwt-bearer-token>" # Example org name: "acme-inc export ORG_NAME=<org-name> # Use the JWT bearer token in your API request auth header: curl -v -X GET -H "Content-Type: application/json" -H "Authorization: Bearer $JWT_BEARER_TOKEN" https://nico-rest-api.nico.svc.cluster.local/v2/org/$ORG_NAME/nico/user/current ```

Path parameters

orgstringRequired
Name of the Org

Request

This endpoint expects an object.
siteIdstringRequiredformat: "uuid"
ID of the Site
domainIdslist of stringsRequired

UUIDs of the NVLink Domains to update. IDs must be unique after UUID normalization (case-insensitive).

versionstring or nullOptional
Target firmware version. When empty, null, or omitted, use the default firmware version for each targeted component.
ruleIdstringOptionalformat: "uuid"
Optional Operation Rule UUID. When set, pins every task spawned by this operation to the named rule and overrides Flow's default rule resolution.
overrideReadinessCheckbooleanOptionalDefaults to false

When true, proceed even if one or more target components (or hosts on the owning rack for rack-scoped components) are reported as not ready by their persisted status. Intended for operator-supervised maintenance.

Response

OK
taskIdslist of stringsOptional
List of task IDs created for the firmware update operation

Errors

400
Bad Request Error
403
Forbidden Error
404
Not Found Error
500
Internal Server Error
503
Service Unavailable Error
504
Gateway Timeout Error