To test the PXE and DHCP boot process using a generic QEMU virtual machine, you start qemu w/o graphics support. If the OS is graphical (e.g. ubuntu livecd) remove -nographic and display none to have a GUI window start on desktop.

Bridge Configuration

To allow the QEMU VM to join the bridge network that is used for development, create or edit the file ‘/etc/qemu/bridge.conf’ such that its contents are:

$ cat /etc/qemu/bridge.conf
allow nico0

TPM setup

A TPM (Trusted Platform Module) is a chip that can securely store artifacts used to authenticate the server. We have to pretend to have one.

Install Software TPM emulator

  • On Debian/Ubuntu:

    sudo apt-get install -y swtpm swtpm-tools

Create a directory for emulated TPM state

mkdir /tmp/emulated_tpm

Create initial configuration for the Software TPM

This step makes sure the emulated TPM has certificates.

swtpm_setup --tpmstate /tmp/emulated_tpm --tpm2 --create-ek-cert --create-platform-cert

If you get an error in this step, try the following steps:

  • Run /usr/share/swtpm/swtpm-create-user-config-files. Potentially with --overwrite. This writes the following files:

    • ~/.config/swtpm_setup.conf
    • ~/.config/swtpm-localca.conf
    • ~/.config/swtpm-localca.options
  • Check the content of the file ~/.config/swtpm_setup.conf. If create_certs_tools has @DATAROOT@ in its name, you have run into the bug https://bugs.launchpad.net/ubuntu/+source/swtpm/+bug/1989598 and https://github.com/stefanberger/swtpm/issues/749. To fix the bug, edit /usr/share/swtpm/swtpm-create-user-config-files, search for the place where create_certs_tool is written, and replace it with the correct path to the tool. E.g.

    create_certs_tool = /usr/lib/x86_64-linux-gnu/swtpm/swtpm-localca

    Then run /usr/share/swtpm/swtpm-create-user-config-files again.

Start the TPM emulator

Run the following command in separate terminal to start a software TPM emulation

swtpm socket --tpmstate dir=/tmp/emulated_tpm --ctrl type=unixio,path=/tmp/emulated_tpm/swtpm-sock --log level=20 --tpm2

Note that the process will automatically end if a VM that connects to this socket is restarted. You need to restart the tool if you are restarting the VM.

Start the services and seed the database

  • docker-compose up
  • cargo make bootstrap-nico-docker

If you see “No network segment defined for relay address: 172.20.0.11” in the nico-dhcp output, you forgot to run cargo make bootstrap-nico-docker.

Start the VM

Make sure you have libvirt installed.

  • Create it (once): virsh define dev/libvirt_host.xml (to rebuild first virsh undefine --nvram ManagedHost).
  • Start it: virsh start ManagedHost.
  • Look at the console (not in tmux!): virsh console ManagedHost.
  • Stop it virsh destroy ManagedHost.

You can also use graphical interface virt-manager.

The virtual machine should fail to PXE boot from IPv4 (but gets an IP address) and IPv6, and then succeed from “HTTP boot IPv4”, getting both an IP address and a boot image.

This should boot you into the pre-exec image. The user is root and password is specified in the mkosi.default file.

In order to exit out of console use ctrl-a x

virsh is part of libvirt. Libvirt is a user-friendly layer on top of QEMU (see next section to use it directly). QEMU is a hypervisor, it runs the virtual machine. QEMU uses kernel module KVM, which uses the CPU’s virtualization instructions (Intel-VT or AMD-V).

Start the VM (older, manual)

Do not do this step in tmux or screen. The QEMU escape sequence is Ctrl-a.

With TPM:

sudo qemu-system-x86_64 -boot n -nographic -display none \
-serial mon:stdio -cpu host \
-accel kvm -device virtio-serial-pci \
-netdev bridge,id=nicovm,br=nico0 \
-device virtio-net-pci,netdev=nicovm \
-bios /usr/share/ovmf/OVMF.fd -m 4096 \
-chardev socket,id=chrtpm,path=/tmp/emulated_tpm/swtpm-sock \
-tpmdev emulator,id=tpm0,chardev=chrtpm -device tpm-tis,tpmdev=tpm0

Without TPM:

sudo qemu-system-x86_64 -boot n -nographic -display none \
-serial mon:stdio -cpu host \
-accel kvm -device virtio-serial-pci \
-netdev bridge,id=nicovm,br=nico0 \
-device virtio-net-pci,netdev=nicovm \
-bios /usr/share/ovmf/OVMF.fd -m 4096

On Fedora change the -bios line to -bios /usr/share/OVMF/OVMF_CODE.fd.

Note: There is a known issue where iPXE DHCP fails on the first run. If this occurs, type reset in the EFI Shell to restart the PXE process; it will complete successfully on the second attempt.

Note: Verify the OVMF path for your system — depending on how the ovmf package was installed, the file may be under a subdirectory called x64.

Note: Known older issue on first boot that you’ll land on a UEFI shell, have to exit back into the BIOS and select “Continue” in order to proceed into normal login.

Verify Scout Boot NIC Selection

Scout boots in two stages. The small loader image, scout.efi, downloads scout.squashfs, which contains the full Scout filesystem. The loader then uses systemctl soft-reboot to start that filesystem with the same kernel. The interface selected by the kernel’s mac= argument must remain usable through both stages.

This procedure covers the boot-MAC policy implemented in Apply Scout’s Boot MAC Before Networking Starts for Apply Scout Boot-MAC Policy Before Networking Starts. It describes acceptance requirements, not a record of completed testing. A helper unit test does not establish that the installed systemd units run in the right order or that networking survives the switch between images.

Prepare the Test

Use a disposable VM and an isolated test PXE service. You need permission to change its boot artifacts and overrides, restart the VM, and disconnect its NICs. Retain console access that does not depend on either test NIC.

Prepare the following inputs:

  • Actual loader and full Scout artifacts from the build under test, with the architecture, source revision, and build identifier recorded separately.
  • A copy of the libvirt VM definition, extended to two NICs by duplicating its interface block. Give each block a distinct mac address and target dev. Set each source bridge to the lab bridge for that link. The template uses carbide0; the manual examples above use nico0. Use the bridges that your test environment actually provides. Their guest interface names must match enx*, enp*, or enP*, as Scout’s default network policy requires. Both links must offer DHCP and reach the image server. Confirm the names and connectivity in the control boot.
  • A lab-provided IPv6 router-advertisement source on each link for IPv6 acceptance, with control over advertisements and address assignment.
  • A known LLDP neighbor on each link. Record its chassis and port identifiers so received neighbors can be distinguished from stale observations. The lab must deliver those advertisements to each guest NIC; bridge connectivity alone does not establish LLDP reception.
  • Serial logging and packet capture on both VM links from the start of boot. Keep the captures separate so the sending interface is unambiguous.

Record the exact image hashes before serving each pair:

sha256sum scout.efi scout.squashfs

Record the complete VM configuration and boot command line with those hashes. Serve those exact files from the isolated image server. Retain the served URL to file mapping and access records so the downloaded pair can be correlated with the hashes. For a CPIO full image, hash the actual compressed archive instead of scout.squashfs.

Use the existing boot-override set procedure to control the VM’s iPXE script:

  1. Save the normal Scout iPXE script returned to the VM and any existing boot override, including user data. Identify the resolved machine interface UUID in that script; do not substitute a host machine ID or infer it from boot order.
  2. Copy the complete script into the custom PXE file. Preserve machine_id, server_uri, pxe_uri, the ds=nocloud datasource, console settings, and the remaining arguments. Here, machine_id contains the interface UUID.
  3. Set the loader URL to the served scout.efi. Add one newrootfs= value for the full image under test. Replace the existing mac= with the second NIC’s six colon-separated hexadecimal octets. Keep the first NIC connected and DHCP-capable. For the control boot, remove mac=; for negative cases, replace it with the exact malformed or repeated input being tested.
  4. Apply the custom PXE file to that resolved interface UUID, preserving any existing user-data override. Record the script and confirm the actual /proc/cmdline after boot. Appending another mac= to the normal script tests repeated input, not a new selection.
  5. After testing, restore the saved override. If none existed, use boot-override clear for the same interface UUID.

Start the VM through its PXE path as described in Start the VM. The loader accepts newrootfs=<full-image-url> in the kernel command line. Omission uses http://carbide-static-pxe.forge/public/blobs/internal/<architecture>/scout.squashfs, where <architecture> is the kernel’s machine architecture. If you use this default, test DNS must resolve that name to the isolated image server. URLs ending in .cpio, .cpio.zst, or .cpio.zstd, optionally followed by a query string, select CPIO extraction. These archives must be zstd-compressed regardless of their suffix; other URLs select SquashFS. Supply only one newrootfs= value. Repeated values use the last one; an empty value causes failed download attempts. newrootfs=none keeps the loader running for a separate diagnostic boot; it does not exercise the switch to full Scout.

Check Both Boot Stages

Start packet and serial capture before boot, then perform these checks:

  1. Confirm both NICs receive DHCP in a control boot with mac= omitted. Confirm that the IPv6 advertisements used for testing create an address or route without restrictions, and that full Scout receives LLDP on both links.
  2. Boot the selected-MAC case. Record the loader’s selection and image download on the selected NIC. Let the loader perform its own soft reboot; do not replace this transition with a new VM boot.
  3. After full Scout starts, collect the Scout network diagnostics. Check the effective units and policy files as well as addresses and routes.
  4. Match the selected interface to the supplied MAC in both stages. Require a usable global address and selected-interface egress to the image server. When IPv6 is offered, check IPv6 addresses and routing separately.
  5. Verify that the other data NIC has no global addresses, global IPv4 routes, or non-link-local IPv6 unicast routes in the main routing table. The diagnostics include all tables; local and multicast entries are not failures. Correlate DHCP traffic with the boot stages. Firmware and iPXE DHCP before Linux starts is separate from Scout’s policy. With a usable selection and the new policy active, DHCP must use the selected NIC. Reuse the control advertisements and confirm that they create no competing addresses or routes.
  6. Verify fresh received LLDP neighbors on both links. Confirm that cloud-init still consumes the lab’s metadata and user data after the image switch. Retain the delivered metadata and a known result of the test user data, such as a file it writes, alongside cloud-init’s completion record.

Run the following commands in full Scout to identify the kernel boot and received neighbors:

cat /proc/sys/kernel/random/boot_id
lldpcli -f json show neighbors

Where console access allows it, record the boot ID before and after the switch by repeating the boot-ID read in the loader. LLDP collection runs in full Scout, not in the loader. The boot ID remains unchanged across a soft reboot. Retain the loader’s download and selection records from its journal or console capture before the switch. Do not assume a later journal contains them. Correlate the loader’s LOADER: Cleaning up & switching message with soft-reboot completion and full-image units starting, including forge-scout.service. An unchanged boot ID alone does not prove a switch. LLDP transmission or carrier alone does not prove that neighbors were received.

Check Recovery and Image Compatibility

Use a fresh boot for each input or image-pair change. While broad fallback is active, verify that an HTTP request bound to the alternate NIC succeeds. After selection returns, require egress on the selected NIC and withdrawal of competing configuration. Record timestamps, helper results, unit state, and networking before and after each transition.

For the duplicate-MAC case only, configure both guest NICs to report the same MAC and supply one mac= argument with that address. Restore distinct MAC addresses before running the other cases.

The recovery cases have distinct expected results:

CaseExpected Result
Missing, repeated, or malformed mac=Broad bootstrap remains available; no selected-MAC runtime policy survives.
Both guest NICs report the selected MAC on a fresh bootReadiness triggers broad recovery immediately. After successful recovery, the later configuration call reports result=skipped, reason=preferred_interface_count, and exit_status=0.
Valid MAC with no matching NIC, no carrier, or no usable addressThe bounded readiness check restores broad networking; the alternate NIC can obtain an address.
Selected link returns after fallbackA later configuration attempt restores selected-interface networking and removes competing addresses and routes.
Selected IPv6 address remains tentative or fails duplicate-address detection, with no other usable global addressIt does not count as a usable address; readiness waits or falls back.
Loader kept running with newrootfs=noneSelection and unavailable-NIC recovery still run without downloading another image.

For the IPv6 readiness case, suppress DHCPv4 and other usable IPv6 addresses on the selected NIC. Use the lab’s IPv6 controls to retain a tentative address or introduce a duplicate on that link, then record the guest address flags. A usable IPv4 address would satisfy readiness and invalidate this case.

For retry ownership, fallback results, and wait budgets, refer to Scout Boot NIC Selection. Record Scout service restarts alongside the helper timestamps; each restart can run the configuration check again. To exercise a later attempt explicitly after restoring the selected link, run this command as root inside the disposable guest:

/opt/forge/forge-scout-network.sh

This command changes network configuration. Capture its exit status and repeat the network diagnostics afterward. An operational error must remain visible; do not count a successful alternate-NIC transfer as proof of selected-NIC recovery.

Repeat the selected-NIC and handoff checks with these image pairs. Here, new includes PR #7671, and old predates it. Record each source revision. Choose images of the same architecture whose loader supports the full-image format. The full root must supply modules compatible with the loader’s kernel; retain the kernel release and required-driver evidence for each pair. A module mismatch invalidates the fixture, not the boot-MAC policy.

LoaderFull ScoutRequired Handoff Behavior
NewNewApply the selected-interface and packet checks to both stages.
OldNewThe old loader can configure other NICs before its later cleanup. Apply the early-policy checks to full Scout. To prove legacy cleanup, record the old loader’s rule before the switch and its removal in the full image.
NewOldApply the early-policy checks to the loader. In the old full image, verify selected-interface egress and the legacy exclusion when selection was usable at handoff; otherwise verify broad networking.

For the last pair, inspect the old root’s /etc/systemd/network/00-forge-scout-nonpreferred.network. With usable selection at handoff, it must exist and its Property=!INTERFACE= match must exclude the selected interface in the old root. Without usable selection at handoff, the file must be absent. An exclusion matching every data NIC is a failure. The old full image retains its own recovery behavior; these checks do not establish recovery from a link lost after handoff. A modified unpacked filesystem does not identify the artifacts actually shipped.

Verify Core Discovery and Multi-DPU Hardware

Use a test Core deployment with permission to inspect its effective configuration, DHCP ownership, and discovery records. Set and record allow_insecure_discovery = false; the repository’s Docker development configuration explicitly sets it to true. With false, Core validates the request’s remote IP rather than trusting its supplied interface ID.

Use Core’s DHCP and PXE services for this check, with the selected NIC’s lease recorded in Core. Retain the Core-observed source address, owning machine interface, reported host identity, and successful discovery result. Require that source address to equal the selected NIC’s lease and that its owning interface MAC equal mac=. Correlate the Core request records with the stored interface and the guest diagnostics. Successful discovery through the other NIC during fallback does not satisfy this check. Do not count malformed-input boots as discovery acceptance or describe IP validation alone as client-certificate authentication.

QEMU user-mode networking translates guest addresses. It cannot establish Core’s remote-IP ownership check against the guest’s private DHCP address. Likewise, starting an extracted loader kernel directly bypasses UEFI and iPXE. Record these limits when using either technique for Linux networking tests.

To validate firmware and DPU behavior, run separate physical acceptance on a designated multi-DPU machine with authorization to change its served artifacts, reboot it, and disconnect links. Retain independent console or BMC access. Keep the same artifact, command-line, address, route, and discovery evidence as for the VM, plus firmware boot order, selected MAC and PCI device, each DPU’s link and LLDP observations, and captures across the real image switch. Repeat the unavailable-link recovery and secure discovery checks there. Record architecture-specific results separately; an x86 VM run does not establish Arm, BlueField driver, or firmware behavior.